Antonios Emmanouil Gkikakis

Dr. Antonios Emmanouil Gkikakis


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

19 June 2023 in Machines
Verified
Journal Article
Open access
PDF file
KSKapil Sawant
Kapil Sawant
AGAntonios Emmanouil Gkikakis
Antonios Emmanouil Gkikakis
Leonardo S. MattosLeonardo S. Mattos
Leonardo S. Mattos
Continuum manipulators, with their characteristics of flexibility and dexterity, have gained significant interest in various applications across industries such as inspection, manufacturing, space exploration, and medical surgery. However, because of their inherent compliance, handling payloads may prove challenging due to shape distortion and deflection. This demonstrates the need to optimize the manipulator’s stiffness. The primary objective of this work was to show the merits of sensitivity analysis in the design of flexible surgical manipulators. Such analysis can guide important design decisions and enable the more efficient use of available resources, contributing to designing more effective prototypes. A new sensitivity analysis framework based on a multi-model and a multi-method approach was proposed to achieve this. This framework was then demonstrated by studying a tendon-driven rolling contact joint hyper-redundant manipulator for transoral laser microsurgery. In this analysis, the effects of independent design parameters on the stiffness of the manipulator were examined. Then, scaled-up 3D-printed prototypes were used to validate the accuracy of the stiffness model experimentally, which enabled us to assess the outcome of the sensitivity analysis framework. The results demonstrated that only two out of five design parameters for the considered manipulator significantly impacted the device’s performance. This information could enable the designer to efficiently allocate resources toward correctly setting these two most important parameters to achieve the desired system. Overall, the proposed analysis framework is a general tool that can be applied to any design architecture, helping to develop optimal manipulators for various applications.

19 August 2024 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
FAFederico Allione
Federico Allione
AGAntonios Emmanouil Gkikakis
Antonios Emmanouil Gkikakis
CNChristian Di Natali
Christian Di Natali
Darwin G. CaldwellDarwin G. Caldwell
Darwin G. Caldwell
This letter presents the prototype of a human-sized, untethered athletic hopping and balancing underactuated monopedal robot designed to withstand crash landings. Experimental results in 2D of the robot balancing on an unstable contact point, hopping vertically, landing back, and balancing within a narrow point of 2.5 cm are presented and discussed. Furthermore, the first application of a new linear transmission mechanism called the ring screw, an alternative to the ball screw, is presented. The hopping ability of two robots, one equipped with a commercially available ball screw and one with the ring screw, is compared, with the latter achieving a hopping height of 34 cm, three times higher than the former, thanks to its capability to provide extra power derived from its higher speed limit.

6 December 2021
Verified
Conference Paper
Closed access
FAFederico Allione
Federico Allione
BSB. Roodra P. Singh
B. Roodra P. Singh
AGAntonios Emmanouil Gkikakis
Antonios Emmanouil Gkikakis
RFRoy Featherstone
Roy Featherstone
Mobile robots are increasingly being deployed in uncertain, unknown, and/or dangerous environments where they risk being subjected to mechanical shocks due to impacts and falls. If robots are to withstand such shocks then we need to know more about the shock resistance of their component parts. This paper presents an experiment in which two types of rotary encoder and a computational unit are subjected to shocks of various magnitudes. The main results are that shocks as low as 45 g can cause momentary communication errors between the absolute encoder and the control unit, but shocks as high as 128 g do not cause any persistent change in the behaviour of the system.


1 October 2025
Verified
Book Chapter
Closed access
PDF file
Nicholas CartocciNicholas Cartocci
Nicholas Cartocci
AGAntonios Emmanouil Gkikakis
Antonios Emmanouil Gkikakis
NKNatalia Kurvina
Natalia Kurvina
NTNatnael Takele
Natnael Takele
FPFabio Pera
Fabio Pera
JOJesus Ortiz
Jesus Ortiz