Gang Wang

Dr. Gang Wang

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Energy and Buildings
Verified
Journal Article
Closed access
YYYunyang Ye
Yunyang Ye
WZWangda Zuo
Wangda Zuo
GWGang Wang
Gang Wang

22 October 2022 in Energy and Buildings
Verified
Journal Article
Closed access
GWGang Wang
Gang Wang
SGSaeed Ghoddousi
Saeed Ghoddousi
LDLi Ding
Li Ding
LSLi Song
Li Song

1 May 2019 in Energy and Buildings
Verified
Journal Article
Closed access
ZWZufen Wang
Zufen Wang
EAEsber Andiroglu
Esber Andiroglu
GWGang Wang
Gang Wang
LSLi Song
Li Song

11 August 2022 in Journal of Building Engineering
Verified
Journal Article
Closed access
GWGang Wang
Gang Wang
SGSaeed Ghoddousi
Saeed Ghoddousi
ZWZufen Wang
Zufen Wang
LSLi Song
Li Song

31 May 2018 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
GWGang Wang
Gang Wang
Electric motor-driven fan, pump, and compressor systems accounted for 27% of the electricity usage in commercial sectors in United States in 2013. Therefore, even small efficiency improvements will produce very large energy savings. In fact, the efficiency of these systems deteriorates over their lifetime. The efficiency of motors could degrade by up to 5% while the efficiency of pumps could degrade by up to 25%. Since variable frequency drives (VFDs) are widely applied on electric motors, the efficiency degradation is more often concealed by the significant energy reduction introduced by VFDs. The purpose of this paper is to develop and demonstrate an approach, which can effectively detect the efficiency degradation of VFD-motor-pump systems by simply measuring the pump water flow rate and head as well as the system input power. First, the ideal system efficiency was modeled by combining the pump, motor, and VFD efficiencies and applied to correlate the pump water flow rate and head to the ideal system input power. Then, an experiment was conducted on a ten-year-old VFD-motor-pump system to quantify the efficiency degradation by comparing the measured and ideal system input power. The results of the experiment reveal that the efficiency of the studied system degraded by 19%.

16 March 2019 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
GWGang Wang
Gang Wang
ZWZufen Wang
Zufen Wang
LSLi Song
Li Song
The water flow rate through a pump can be calculated using other measured inputs, such as pump head, motor input power, and frequency, along with calibrated characteristic curves. Currently virtual pump flowmeters can be classified into three categories—pump head based, shaft power based, and pump efficiency based—based on which measured inputs and characteristic curves are applied. Thus, different virtual meters may have different flow measurement errors propagated from different measured inputs and curve fittings. This article aims to evaluate the measurement uncertainties of these three virtual meters. First, mathematical models of virtual flow measurement and uncertainty analysis are introduced for three virtual meters. Then through experiments on a 125 m3/h pump, three virtual meters are developed and the uncertainties of the developed virtual meters are evaluated. Finally, the water flow rates measured by three virtual meters are compared with those measured by an ultrasonic flowmeter. Both the uncertainty analysis and flow measurement comparison show that the pump head–based and shaft power–based virtual meters have unacceptable uncertainties, 13 m3/h and 17 m3/h, respectively, at lower frequencies due to the mismatch between the pump speed and motor input frequency. In contrast, the pump efficiency–based virtual meter always remains a robust accuracy with uncertainties less than 1.9 m3/h.