Droplet generation has been widely used in conventional two-dimensional (2D) microfluidic devices, and has recently begun to be explored for 3D-printed droplet generators. A major challenge for 3D-printed devices is preventing water-in-oil droplets from sticking to the interior surfaces of the droplet generator when the device is not made from hydrophobic materials. In this study, two approaches were investigated and shown to successfully form droplets in 3D-printed microfluidic devices. First, several printing resin candidates were tested to evaluate their suitability for droplet formation and material properties. We determined that a hexanediol diacrylate/lauryl acrylate (HDDA/LA) resin forms a solid polymer that is sufficiently hydrophobic to prevent aqueous droplets (in a continuous oil flow) from attaching to the device walls. The second approach uses a fully 3D annular channel-in-channel geometry to form microfluidic droplets that do not contact channel walls, and thus, this geometry can be used with hydrophilic resins. Stable droplets were shown to form using the channel-in-channel geometry, and the droplet size and generation frequency for this geometry were explored for various flow rates for the continuous and dispersed phases.
New microfluidic lab-on-a-chip capabilities are enabled by broadening the toolkit of devices that can be created using microfabrication processes. For example, complex geometries made possible by 3D printing can be used to approach microfluidic design and application in new or enhanced ways. In this paper, we demonstrate three distinct designs for microfluidic one-way (check) valves that can be fabricated using digital light processing stereolithography (DLP-SLA) with a poly(ethylene glycol) diacrylate (PEGDA) resin, each with an internal volume of 5–10 nL. By mapping flow rate to pressure in both the forward and reverse directions, we compare the different designs and their operating characteristics. We also demonstrate pumps for each one-way valve design comprised of two one-way valves with a membrane valve displacement chamber between them. An advantage of such pumps is that they require a single pneumatic input instead of three as for conventional 3D-printed pumps. We also characterize the achievable flow rate as a function of the pneumatic control signal period. We show that such pumps can be used to create a single-stage diffusion mixer with significantly reduced pneumatic drive complexity.
New heater geometries enabled by 3D printing provide improved spatial temperature distributions to typical heaters, validated through simulations and experiments. A first set of design rules to guide truly 3D microfluidic heater design is provided.