Tao Sun

Dr. Tao Sun

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2022 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
TSTao Sun
Tao Sun
ZWZhenguo Wang
Zhenguo Wang
YWYaping Wu
Yaping Wu
FGFengyun Gu
Fengyun Gu
XLXiaochen Li
Xiaochen Li
MWMeiyun Wang
Meiyun Wang
Introduction: Distinct physiological states arise from complex interactions among the various organs present in the human body. PET is a non-invasive modality with numerous successful applications in oncology, neurology, and cardiology. However, while PET imaging has been applied extensively in detecting focal lesions or diseases, its potential in detecting systemic abnormalities is seldom explored, mostly because total-body imaging was not possible until recently. Methods: In this context, the present study proposes a framework capable of constructing an individual metabolic abnormality network using a subject’s whole-body 18F-FDG SUV image and a normal control database. The developed framework was evaluated in the patients with lung cancer, the one discharged after suffering from Covid-19 disease, and the one that had gastrointestinal bleeding with the underlying cause unknown. Results: The framework could successfully capture the deviation of these patients from healthy subjects at the level of both system and organ. The strength of the altered network edges revealed the abnormal metabolic connection between organs. The overall deviation of the network nodes was observed to be highly correlated to the organ SUV measures. Therefore, the molecular connectivity of glucose metabolism was characterized at a single subject level. Conclusion: The proposed framework represents a significant step toward the use of PET imaging for identifying metabolic dysfunction from a systemic perspective. A better understanding of the underlying biological mechanisms and the physiological interpretation of the interregional connections identified in the present study warrant further research.

14 September 2022 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
TSTao Sun
Tao Sun
YWYaping Wu
Yaping Wu
WWWei Wei
Wei Wei
FFFangfang Fu
Fangfang Fu
NMNan Meng
Nan Meng
MWMeiyun Wang
Meiyun Wang
Background: The total-body positron emission tomography (PET) scanner provides an unprecedented opportunity to scan the whole body simultaneously, thanks to its long axial field of view and ultrahigh temporal resolution. To fully utilize this potential in clinical settings, a dynamic scan would be necessary to obtain the desired kinetic information from scan data. However, in a long dynamic acquisition, patient movement can degrade image quality and quantification accuracy. Methods: In this work, we demonstrated a motion correction framework and its importance in dynamic total-body FDG PET imaging. Dynamic FDG scans from 12 subjects acquired on a uEXPLORER PET/CT were included. In these subjects, 7 are healthy subjects and 5 are those with tumors in the thorax and abdomen. All scans were contaminated by motion to some degree, and for each the list-mode data were reconstructed into 1-min frames. The dynamic frames were aligned to a reference position by sequentially registering each frame to its previous neighboring frame. We parametrized the motion fields in-between frames as diffeomorphism, which can map the shape change of the object smoothly and continuously in time and space. Diffeomorphic representations of motion fields were derived by registering neighboring frames using large deformation diffeomorphic metric matching. When all pairwise registrations were completed, the motion field at each frame was obtained by concatenating the successive motion fields and transforming that frame into the reference position. The proposed correction method was labeled SyN-seq. The method that was performed similarly, but aligned each frame to a designated middle frame, was labeled as SyN-mid. Instead of SyN, the method that performed the sequential affine registration was labeled as Aff-seq. The original uncorrected images were labeled as NMC. Qualitative and quantitative analyses were performed to compare the performance of the proposed method with that of other correction methods and uncorrected images. Results: The results indicated that visual improvement was achieved after correction of the SUV images for the motion present period, especially in the brain and abdomen. For subjects with tumors, the average improvement in tumor SUVmean was 5.35 ± 4.92% (P = 0.047), with a maximum improvement of 12.89%. An overall quality improvement in quantitative Ki images was also observed after correction; however, such improvement was less obvious in K1 images. Sampled time–activity curves in the cerebral and kidney cortex were less affected by the motion after applying the proposed correction. Mutual information and dice coefficient relative to the reference also demonstrated that SyN-seq improved the alignment between frames over non-corrected images (P = 0.003 and P = 0.011). Moreover, the proposed correction successfully reduced the inter-subject variability in Ki quantifications (11.8% lower in sampled organs). Subjective assessment by experienced radiologists demonstrated consistent results for both SUV images and Ki images. Conclusion: To conclude, motion correction is important for image quality in dynamic total-body PET imaging. We demonstrated a correction framework that can effectively reduce the effect of random body movements on dynamic images and their associated quantification. The proposed correction framework can potentially benefit applications that require total-body assessment, such as imaging the brain-gut axis and systemic diseases.

2 January 2024 in Cancer Imaging
Verified
Journal Article
Open access
PDF file
YWYaping Wu
Yaping Wu
FFFangfang Fu
Fangfang Fu
NMNan Meng
Nan Meng
ZWZhenguo Wang
Zhenguo Wang
XLXiaochen Li
Xiaochen Li
TSTao Sun
Tao Sun
Objectives: Commercialized total-body PET scanners can provide high-quality images due to its ultra-high sensitivity. We compared the dynamic, regular static, and delayed 18F-fluorodeoxyglucose (FDG) scans to detect lesions in oncologic patients on a total-body PET/CT scanner. Materials & methods: In all, 45 patients were scanned continuously for the first 60 min, followed by a delayed acquisition. FDG metabolic rate was calculated from dynamic data using full compartmental modeling, whereas regular static and delayed SUV images were obtained approximately 60- and 145-min post-injection, respectively. The retention index was computed from static and delayed measures for all lesions. Pearson’s correlation and Kruskal–Wallis tests were used to compare parameters. Results: The number of lesions was largely identical between the three protocols, except MRFDG and delayed images on total-body PET only detected 4 and 2 more lesions, respectively (85 total). FDG metabolic rate (MRFDG) image-derived contrast-to-noise ratio and target-to-background ratio were significantly higher than those from static standardized uptake value (SUV) images (P < 0.01), but this is not the case for the delayed images (P > 0.05). Dynamic protocol did not significantly differentiate between benign and malignant lesions just like regular SUV, delayed SUV, and retention index. Conclusion: The potential quantitative advantages of dynamic imaging may not improve lesion detection and differential diagnosis significantly on a total-body PET/CT scanner. The same conclusion applied to delayed imaging. This suggested the added benefits of complex imaging protocols must be weighed against the complex implementation in the future. Clinical relevance: Total-body PET/CT was known to significantly improve the PET image quality due to its ultra-high sensitivity. However, whether the dynamic and delay imaging on total-body scanner could show additional clinical benefits is largely unknown. Head-to-head comparison between two protocols is relevant to oncological management.

14 September 2022 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
ZWZhenguo Wang
Zhenguo Wang
YWYaping Wu
Yaping Wu
XLXiaochen Li
Xiaochen Li
YBYan Bai
Yan Bai
HCHongzhao Chen
Hongzhao Chen
TSTao Sun
Tao Sun
Purpose: Efforts have been made both to avoid invasive blood sampling and to shorten the scan duration for dynamic positron emission tomography (PET) imaging. A total-body scanner, such as the uEXPLORER PET/CT, can relieve these challenges through the following features: First, the whole-body coverage allows for noninvasive input function from the aortic arteries; second, with a dramatic increase in sensitivity, image quality can still be maintained at a high level even with a shorter scan duration than usual. We implemented a dual-time-window (DTW) protocol for a dynamic total-body 18F-FDG PET scan to obtain multiple kinetic parameters. The DTW protocol was then compared to several other simplified quantification methods for total-body FDG imaging that were proposed for conventional setup. Methods: The research included 28 patient scans performed on an uEXPLORER PET/CT. By discarding the corresponding data in the middle of the existing full 60-min dynamic scan, the DTW protocol was simulated. Nonlinear fitting was used to estimate the missing data in the interval. The full input function was obtained from 15 subjects using a hybrid approach with a population-based image-derived input function. Quantification was carried out in three areas: the cerebral cortex, muscle, and tumor lesion. Micro- and macro-kinetic parameters for different scan durations were estimated by assuming an irreversible two-tissue compartment model. The visual performance of parametric images and region of interest-based quantification in several parameters were evaluated. Furthermore, simplified quantification methods (DTW, Patlak, fractional uptake ratio [FUR], and standardized uptake value [SUV]) were compared for similarity to the reference net influx rate Ki. Results: Ki and K1 derived from the DTW protocol showed overall good consistency (P < 0.01) with the reference from the 60-min dynamic scan with 10-min early scan and 5-min late scan (Ki correlation: 0.971, 0.990, and 0.990; K1 correlation: 0.820, 0.940, and 0.975 in the cerebral cortex, muscle, and tumor lesion, respectively). Similar correlationss were found for other micro-parameters. The DTW protocol had the lowest bias relative to standard Ki than any of the quantification methods, followed by FUR and Patlak. SUV had the weakest correlation with Ki. The whole-body Ki and K1 images generated by the DTW protocol were consistent with the reference parametric images. Conclusions: Using the DTW protocol, the dynamic total-body FDG scan time can be reduced to 15 min while obtaining accurate Ki and K1 quantification and acceptable visual performance in parametric images. However, the trade-off between quantification accuracy and protocol implementation feasibility must be considered in practice. We recommend that the DTW protocol be used when the clinical task requires reliable visual assessment or quantifying multiple micro-parameters; FUR with a hybrid input function may be a more feasible approach to quantifying regional metabolic rate with a known lesion position or organs of interest.

10 November 2022 in Frontiers in Oncology
Verified
Journal Article
Open access
XWXieraili Wumener
Xieraili Wumener
YZYarong Zhang
Yarong Zhang
ZWZhenguo Wang
Zhenguo Wang
MZMaoqun Zhang
Maoqun Zhang
ZZZihan Zang
Zihan Zang
TSTao Sun
Tao Sun
Objectives: 18F-fluorodeoxyglucose (FDG) PET/CT has been widely used in tumor diagnosis, staging, and response evaluation. To determine an optimal therapeutic strategy for lung cancer patients, accurate staging is essential. Semi-quantitative standardized uptake value (SUV) is known to be affected by multiple factors and may fail to differentiate between benign and malignant lesions. Lymph nodes (LNs) in the mediastinal and pulmonary hilar regions with high FDG uptake due to granulomatous lesions such as tuberculosis, which has a high prevalence in China, pose a diagnostic challenge. This study aims to evaluate the diagnostic value of the quantitative metabolic parameters derived from dynamic 18F-FDG PET/CT in differentiating metastatic and non-metastatic LNs in lung cancer.Methods: One hundred and eight patients with pulmonary nodules were enrolled to perform 18F-FDG PET/CT dynamic + static imaging with informed consent. One hundred and thirty-five LNs in 29 lung cancer patients were confirmed by pathology. Static image analysis parameters including LN-SUVmax, LN-SUVmax/primary tumor SUVmax (LN-SUVmax/PT-SUVmax), mediastinal blood pool SUVmax (MBP-SUVmax), LN-SUVmax/MBP-SUVmax, and LN-SUVmax/short diameter. Quantitative parameters including K1, k2, k3 and Ki and of each LN were obtained by applying the irreversible two-tissue compartment model using in-house Matlab software. Ki/K1 was computed subsequently as a separate marker. We further divided the LNs into mediastinal LNs (N=82) and pulmonary hilar LNs (N=53). Wilcoxon rank-sum test or Independent-samples T-test and receiver-operating characteristic (ROC) analysis was performed on each parameter to compare the diagnostic efficacy in differentiating lymph node metastases from inflammatory uptake. P&lt;0.05 were considered statistically significant.Results: Among the 135 FDG-avid LNs confirmed by pathology, 49 LNs were non-metastatic, and 86 LNs were metastatic. LN-SUVmax, MBP-SUVmax, LN-SUVmax/MBP-SUVmax, and LN-SUVmax/short diameter couldn’t well differentiate metastatic from non-metastatic LNs (P>0.05). However, LN-SUVmax/PT-SUVmax have good performance in the differential diagnosis of non-metastatic and metastatic LNs (P=0.039). Dynamic metabolic parameters in addition to k3, the parameters including K1, k2, Ki, and Ki/K1, on the other hand, have good performance in the differential diagnosis of metastatic and non-metastatic LNs (P=0.045, P=0.001, P=0.001, P=0.001, respectively). For ROC analysis, the metabolic parameters Ki (AUC of 0.672 [0.579-0.765], sensitivity 0.395, specificity 0.918) and Ki/K1 (AUC of 0.673 [0.580-0.767], sensitivity 0.570, specificity 0.776) have good performance in the differential diagnosis of metastatic from non-metastatic LNs than SUVmax (AUC of 0.596 [0.498-0.696], sensitivity 0.826, specificity 0.388), included the mediastinal region and pulmonary hilar region.Conclusion: Compared with SUVmax, quantitative parameters such as K1, k2, Ki and Ki/K1 showed promising results for differentiation of metastatic and non-metastatic LNs with high uptake. The Ki and Ki/K1 had a high differential diagnostic value both in the mediastinal region and pulmonary hilar region.

9 June 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
TSTao Sun
Tao Sun
RJReinhilde Jacobs
Reinhilde Jacobs
RPRuben J Pauwels
Ruben J Pauwels
ETElisabeth Tijskens
Elisabeth Tijskens
RFRoger R Fulton
Roger R Fulton
JNJohan Nuyts
Johan Nuyts
Patient movement affects image quality in oral and maxillofacial cone-beam computed tomography imaging. While many efforts are made to minimize the possibility of motion during a scan, relatively little attention has been given to motion correction after acquisition. We propose a novel method which can improve the image quality after an oral and maxillofacial scan. The proposed method is based on our previous work and is a retrospective motion estimation and motion compensation (ME/MC) approach that iteratively estimates and compensates for rigid pose change over time. During motion estimation, image update and motion update are performed alternately in a multi-resolution scheme to obtain the motion. We propose use of a feature-based motion update and patch-based image update in the iterative estimation process, to alleviate the effect of limited scan field of view on estimation. During motion compensation, a fine-resolution image reconstruction was performed with compensation for the estimated motion. The proposed ME/MC method was evaluated with simulations, phantom and patient studies. Two experts in dentomaxillofacial radiology assessed the diagnostic importance of the resulting motion artifact suppression. The quality of the reconstructed images was improved after motion compensation, and most of the image artifacts were eliminated. Quantitative analysis by comparison to a reference image and by calculation of a sharpness metric agreed with the qualitative observation. The results are promising, and further evaluation is required to assess the clinical value of the proposed method.