Platypus is the first system to localize and identify people by remotely and passively sensing changes in their body electric potential which occur naturally during walking. While it uses three or more electric potential sensors with a maximum range of 2 m, as a tag-free system it does not require the user to carry any special hardware. We describe the physical principles behind body electric potential changes, and a predictive mathematical model of how this affects a passive electric field sensor. By inverting this model and combining data from sensors, we infer a method for localizing people and experimentally demonstrate a median localization error of 0.16 m. We also use the model to remotely infer the change in body electric potential with a mean error of 8.8 % compared to direct contact-based measurements. We show how the reconstructed body electric potential differs from person to person and thereby how to perform identification. Based on short walking sequences of 5 s, we identify four users with an accuracy of 94 %, and 30 users with an accuracy of 75 %. We demonstrate that identification features are valid over multiple days, though change with footwear
Three experiments were carried out to determine absolute and differential thresholds for vibrotactile forces and external influences in the frequency range of 5 to 1,000 Hz at the tip of the index finger. Differential thresholds were obtained for reference stimuli of 0.5, 0.25 N, and near the individual threshold. Frequency, temperature, age, fingertip size, and contact force were investigated as parameters in a full-factorial design. Experiments were conducted with at least 27 subjects and a 1up-2down staircase procedure with 3IFC paradigm. We find absolute thresholds ranging from 1.7 to 19 mN with the lowest threshold at 320 Hz. Weber fractions from 18 to 41 dB are found near the absolute threshold. For larger references, they range from 4.9 to 23 dB. ANOVA finds frequency as significant medium effect for both absolute and differential thresholds. Results imply impact of age on the absolute threshold, but no effect of motor skill, temperature, fingertip size, and contact force. Differential thresholds are affected by frequency only, which is attributed to saturation effects of the Pacinian channel. Fingertip size and motor skill are not able to explain effects on thresholds and the interpersonal variance. Results of this work are intended as requirement source for the design of task-specific haptic interfaces.
Physical Unclonable Functions (PUFs) based on the retention times of the cells of a Dynamic Random Access Memory (DRAM) can be utilised for the implementation of cost-efficient and lightweight cryptographic protocols. However, as recent work has demonstrated, the times needed in order to generate their responses may prohibit their widespread usage. To address this issue, the Row Hammer PUF has been proposed by Schaller et al., which leverages the row hammer effect in DRAM modules to reduce the retention times of their cells and, therefore, significantly speed up the generation times for the responses of PUFs based on these retention times. In this work, we extend the work of Schaller et al. by presenting a run-time accessible implementation of this PUF and by further reducing the time required for the generation of its responses. Additionally, we also provide a more thorough investigation of the effects of temperature variations on the Row Hammer PUF and briefly discuss potential statistical relationships between the cells used to implement it. As our results prove, the Row Hammer PUF could potentially provide an adequate level of security for Commercial Off-The-Shelf (COTS) devices, if its dependency on temperature is mitigated, and, may therefore, be commercially adopted in the near future.
Miniaturized force/torque sensors are relevant components for robotic interaction with humans and unknown environments. This paper presents a disruptive manufacturing process for multiaxial force/torque sensors based on a Stewart-Gough platform. The deformation element consists of a hexapod geometry with six sensing elements with a total diameter of 9 mm. The sensor manufacturing process is divided into three steps: 1. Milling a planar arrangement of sensing elements out of a 2 mm steel (1 .4301) plate, 2. applying twelve strain gauges in half-bridge configuration and 3. rolling the elements into a hexapod structure. The dimensions of the sensing elements are scalable to adjust the size and nominal measurement range of the sensor. The first prototype has a measuring range of 4 N and 66 mNm. The characterization of the sensor shows a maximal linearity and hysteresis error of 1.16% and a cross-sensitivity smaller than 2.76% .
1 January 2010 in Lecture Notes in Computer Science