With the expansion of renewable energy sources, the stable and high-quality operation of microgrids composed of new energy sources has attracted widespread attention. Among them, the power conversion system (PCS), as an important part of microgrids, plays a crucial role in their operation and management. The PCS operation modes are classified into grid-connected and off-grid modes. However, in off-grid mode, due to the access of nonlinear and unbalanced loads, the output voltage quality of a PCS is worse, and the voltage waveform distortion is serious. To solve these problems, a fast repetitive control (FRC) strategy is proposed for a power conversion system with an Active Neutral Point Clamped (ANPC) architecture of three levels. The voltage loop control strategy can be applied to the voltage/frequency () mode and the grid-forming mode. The control strategy can effectively realize the suppression of the harmonics of the output voltage and has a 100% capability to carry unbalanced loads. Finally, a 1725 kVA PCS prototype is developed, and the proposed control strategy is verified using the MT3200 HIL semiphysical simulator of ModelingTech in the mode as an example. This practically verifies the feasibility and validity of the proposed control strategy, which has a certain degree of engineering practicability and reference due to the simplicity of the design and the ease of realization.
This paper proposes a hierarchical current-limiting strategy for power conversion systems oper-ating as grid-forming virtual synchronous generators (VSGs). The strategy coordinates adaptiveactive/reactive power reference reconstruction, transient virtual impedance (TVI), and circularcurrent-vector limiting so that the converter can suppress fault current while retaining voltage-source behavior as far as the hardware constraints allow. The final stability and ride-through capability are evaluated through a 10-kVA hardware prototype under islanded load steps, overload operation, grid-connected frequency disturbance, and single-phase, two-phase, three-phase, and phase-angle-jump fault scenarios. Comparative tests with a conventional virtual-impedance-plus-current-limiting method show that the proposed hierarchical coordination reduces fault-entry and fault-clearance current transients and improves post-fault recovery. The results demonstrate that staged coordination among power limiting, TVI, and direct current limiting provides a practical solution for grid-forming VSGs with limited overcurrent capacity.
This study presents the first peer-reviewed multi-year field performance analysis of an operational 50 kWp monocrystalline photovoltaic (PV) system installed at Andijan State Technical Institute (ADTI, 40.78°N, 72.34°E), Uzbekistan, covering 40 months of Growatt-platform monitoring data from January 2023 through April 2026. The 2024 full-year reference dataset reveals an annual PV yield of 61,945 kWh (specific yield: 1,239 kWh/kWp/year; annual average capacity factor: 14.1%), establishing the first field-validated solar resource benchmark for the Andijan region. A critical seasonal asymmetry is quantified: summer months (June–August) yield an average 8,797 kWh/month compared to 675 kWh/month in winter (December–February), a 13.0× ratio that fundamentally governs hydrogen storage strategy. Coupling the measured PV data with experimentally validated alkaline water electrolysis parameters for 316L stainless steel electrodes — characterized across 1,000 hours of continuous operation in our prior publications — annual hydrogen production potential is quantified at 178.6 kg/year (current 9.6% energy efficiency) and 520.9 kg/year (improved 28% efficiency through NiFe catalyst, zero-gap architecture, and 70°C operation). Minimum seasonal hydrogen storage of 32.6 kg is required for uniform year-round supply continuity. Techno-economic analysis yields levelized cost of hydrogen (LCOH) of $1.3/kg (current) and $0.67/kg (improved system) at campus scale, falling to $0.4/kg at 1 MW scale. Over the 40-month measurement period, the ADTI system has avoided 63.1 tonnes of CO₂ emissions. Multi-year data confirm resource stability with year-on-year summer peak yields in the two most stable comparable months (April Δ = +1.1%; May Δ = +5.2%), validating the 2024 dataset as a representative regional benchmark. These results provide the first evidence-based foundation for solar hydrogen feasibility planning in Uzbekistan, directly supporting the country’s raised 40% renewable electricity target by 2030.
1 October 2026 in IEEE Journal of Emerging and Selected Topics in Industrial Electronics