Mustafa M.Ali

Dr. Mustafa M.Ali

University of Kerbala, Karbala, Iraq
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in Journal of Constructional Steel Research
Verified
Journal Article
Closed access
Ahmed W. Al ZandAhmed W. Al Zand
Ahmed W. Al Zand
WBWan Hamidon W. Badaruzzaman
Wan Hamidon W. Badaruzzaman
MAMarwan S. Al-Shaikhli
Marwan S. Al-Shaikhli
Mustafa M.AliMustafa M.Ali
Mustafa M.Ali

1 November 2021 in Journal of Building Engineering
Verified
Journal Article
Closed access
AZAhmed W. Al Zand
Ahmed W. Al Zand
EHEmad Hosseinpour
Emad Hosseinpour
WBWan Hamidon W. Badaruzzaman
Wan Hamidon W. Badaruzzaman
Mustafa M.AliMustafa M.Ali
Mustafa M.Ali
ZYZaher Mundher Yaseen
Zaher Mundher Yaseen
AHAmmar N. Hanoon
Ammar N. Hanoon

23 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
Ahmed W. Al ZandAhmed W. Al Zand
Ahmed W. Al Zand
Mustafa M.AliMustafa M.Ali
Mustafa M.Ali
Riyadh Al-AmeriRiyadh Al-Ameri
Riyadh Al-Ameri
WBWan Hamidon Wan Badaruzzaman
Wan Hamidon Wan Badaruzzaman
WTWadhah M. Tawfeeq
Wadhah M. Tawfeeq
ZYZaher Mundher Yaseen
Zaher Mundher Yaseen
The flexural strength of Slender steel tube sections is known to achieve significant improvements upon being filled with concrete material; however, this section is more likely to fail due to buckling under compression stresses. This study investigates the flexural behavior of a Slender steel tube beam that was produced by connecting two pieces of C-sections and was filled with recycled-aggregate concrete materials (CFST beam). The C-section’s lips behaved as internal stiffeners for the CFST beam’s cross-section. A static flexural test was conducted on five large scale specimens, including one specimen that was tested without concrete material (hollow specimen). The ABAQUS software was also employed for the simulation and non-linear analysis of an additional 20 CFST models in order to further investigate the effects of varied parameters that were not tested experimentally. The numerical model was able to adequately verify the flexural behavior and failure mode of the corresponding tested specimen, with an overestimation of the flexural strength capacity of about 3.1%. Generally, the study confirmed the validity of using the tubular C-sections in the CFST beam concept, and their lips (internal stiffeners) led to significant improvements in the flexural strength, stiffness, and energy absorption index. Moreover, a new analytical method was developed to specifically predict the bending (flexural) strength capacity of the internally stiffened CFST beams with steel stiffeners, which was well-aligned with the results derived from the current investigation and with those obtained by others.

1 April 2021 in Chemical Physics Letters
Verified
Journal Article
Closed access
TMTeh Sabariah Binti Abd Manan
Teh Sabariah Binti Abd Manan
SBSalmia Beddu
Salmia Beddu
DMDaud Mohamad
Daud Mohamad
NKNur Liyana Mohd Kamal
Nur Liyana Mohd Kamal
WMWan Hanna Melini Wan Mohtar
Wan Hanna Melini Wan Mohtar
NBNur Amalina Nadiah Basri
Nur Amalina Nadiah Basri

1 January 2021 in Latin American Journal of Solids and Structures
Verified
Journal Article
Open access
Mustafa M.AliMustafa M.Ali
Mustafa M.Ali
SOSiti Aminah Osman
Siti Aminah Osman
AAAl Zand Aw
Al Zand Aw
MYM.Y.M. Yatim
M.Y.M. Yatim
FAFaesal Alatshan
Faesal Alatshan
Salam J. HiloSalam J. Hilo
Salam J. Hilo

10 June 2023 in Buildings
Verified
Journal Article
Open access
PDF file
Salam J. HiloSalam J. Hilo
Salam J. Hilo
MHMohammed J. Hamood
Mohammed J. Hamood
Alaa Hussein Al-ZuhairiAlaa Hussein Al-Zuhairi
Alaa Hussein Al-Zuhairi
Ahmed W. Al ZandAhmed W. Al Zand
Ahmed W. Al Zand
A B M AMRUL KAISHA B M AMRUL KAISH
A B M AMRUL KAISH
WBWan Hamidon Wan Badaruzzaman
Wan Hamidon Wan Badaruzzaman
The double-skin profiled composite wall (DSPCW) system, filled with concrete material, is favorable in modern structures due to its high strength and ductility. Openings may be required within this composite wall (DSPCW) for various reasons, similar to a conventional bearing wall, which can lead to a reduction in bearing capacity. Therefore, to avoid changes in the geometry, materials, and thickness of this DSPCW wall, a new internally stiffening concept has been suggested by providing embedded cold-formed steel tube (CFST) columns. For this purpose, two full-scale DSPCW specimens were tested under static axial load, one of which was fabricated with a large opening size and stiffened with two octagonal CFST columns, while the other was designed without an opening and served as a control wall specimen. The results showed that the stiffened DSPCW with an opening achieved a slightly lower ultimate bearing strength (−9.4%) than the control wall specimen, with no reduction in the ductility behavior. Furthermore, several finite element models of DSPCW have been analyzed and designed to investigate additional parameters that were not experimentally tested, including the effects of the embedded CFST column’s shape and different types of internal stiffeners longitudinally provided inside these columns. The numerical investigation confirmed that the embedded CFST column with an octagonal cross-section was more efficient compared to the hexagonal and rectangular shapes by about 11% and 18.4%, respectively. Furthermore, using internal steel stiffeners for embedded tubes with a T-shape improved the axial bearing capacity of the DSPCW with an opening slightly higher than the corresponding stiffened walls with other investigated stiffener shapes (V-shaped, U-shaped, and L-shaped).