Mahmoud Ghazavi

Prof. Mahmoud Ghazavi

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2013 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
JAJavad Nazari Afshar
Javad Nazari Afshar
MGMahmoud Ghazavi
Mahmoud Ghazavi

11 February 2016 in Geotechnical and Geological Engineering
Verified
Journal Article
Closed access
PDF file
ALArash Alimardani Lavasan
Arash Alimardani Lavasan
ATAli Talsaz
Ali Talsaz
MGMahmoud Ghazavi
Mahmoud Ghazavi
TSTom Schanz
Tom Schanz

1 September 2017 in International Journal of Geomechanics
Verified
Journal Article
Closed access
IMIman Mehdipour
Iman Mehdipour
MGMahmoud Ghazavi
Mahmoud Ghazavi
RMReza Ziaie Moayed
Reza Ziaie Moayed
Given the three-dimensional confinement, the geocell reinforcement can act as a beam that can carry both bending and membrane stresses compared with only the planar membrane effect of planar reinforcement. This study presents an analytical approach to determine the factor of safety (FOS) of geocell-reinforced slope using the horizontal slice method (HSM). The geocell reinforcement composed of geocell and infill soil was modeled as a composite beam filled with soil. The improvement in the FOS of the geocell-reinforced slope was expressed in terms of vertical stress dispersion, vertical frictional resistance, and structural mechanisms provided by geocell reinforcement. The effect of geocell pocket diameter on the soil confinement and FOS of geocell-reinforced slope was considered using hoop tension theory. The results of the proposed analytical model were compared with those determined by numerical modeling using the strength reduction method (SRM). A series of parametric analyses were also performed to evaluate the influence of the placement depth of the geocell layer, the number of geocell layers, the pocket diameter and the height of geocell, and the slope angle and soil shear strength, on the stability of the geocell-reinforced slope. The results indicate that the reinforcing mechanism of geocell reinforcement is considerably related to the geocell thickness. The mobilized flexural strength and vertical frictional resistance magnify as the height of the geocell increases. Compared with planar reinforcement, a smaller quantity of geocell reinforcement is required to achieve an equivalent FOS value. The results predicted from the present analytical approach were found to be in good agreement with SRM results.

15 April 2008 in Geotechnical and Geological Engineering
Verified
Journal Article
Closed access
PDF file
MGMahmoud Ghazavi
Mahmoud Ghazavi
AEAmir Hossein Eghbali
Amir Hossein Eghbali

1 March 2018 in Journal of Geotechnical and Geoenvironmental Engineering
Verified
Journal Article
Closed access
ALArash Alimardani Lavasan
Arash Alimardani Lavasan
MGMahmoud Ghazavi
Mahmoud Ghazavi
ABAchim von Blumenthal
Achim von Blumenthal
TSTom Schanz
Tom Schanz
In this paper, the ultimate bearing capacity of two closely spaced rigid strip footings with rough base on granular soil is examined based on enhanced limit equilibrium, plastic limit analyses, and finite-difference solutions. The enhanced limit equilibrium and plastic limit analyses are developed on the basis of two proposed failure mechanisms in association with an optimization algorithm. The limit analysis is conducted by using the kinematic element method (KEM), and finite-difference package is used for numerical simulations. The efficiency factors of bearing capacity are calculated at various spacings between two neighboring footings for practical range of friction angles (25°≤ϕ≤40° ) in accordance with different solutions. Thereafter, the results obtained from the proposed solutions are compared with those reported from existing experimental, theoretical, and numerical studies. In addition, the reliability of the proposed mechanisms is justified through a series of comparisons with the failure patterns and the shear bands obtained from numerical simulations at different spacings. These comparisons indicated that despite the relative simplicity of proposed solutions, bearing capacities and failure patterns are in excellent accordance with numerical, analytical, and experimental results.

1 November 2017 in International Journal of Geomechanics
Verified
Journal Article
Closed access
ALArash Alimardani Lavasan
Arash Alimardani Lavasan
MGMahmoud Ghazavi
Mahmoud Ghazavi
TSTom Schanz
Tom Schanz
This paper numerically examines the bearing capacity, settlement, and failure kinematics of two closely spaced circular footings on reinforced soil. A number of large-scale tests are performed to identify the influence of the tilt of interfering footings on their ultimate bearing capacity and settlement, and these experimental results are used to verify the numerical model. Because the mobilization of shear strength in soil and tensile resistance in the geogrid depend to a large extent on the strain level (especially in small strains), a nonlinear elastic-plastic constitutive model in conjunction with a nonassociated flow rule is proposed. In addition, the model accounts for the dependency of the friction and dilation angles on the strain level in the plastic domain. The constitutive parameters are calibrated for the triaxial loading test, whereas the numerical model for the closely spaced footings is verified with reference to the large-scale test results. Thereafter, the ultimate bearing capacity and settlement of interfering circular footings on reinforced soil are studied for different configurations, and the critical size and position of reinforcements that maximize the bearing capacity are characterized. Results show that the ultimate bearing capacity increases up to a maximum of 40 and 90% by the use of one and two layers of geogrid, respectively. Beyond the bearing capacity, the settlement of adjacent circular footings increases up to 45% (compared with a single footing with the same safety factor). Finally, the influence of reinforcing soil on failure kinematics and soil deformation pattern is investigated.