A sensitive, accurate, robust, and precise analytical quality by design (AQbD)-based RP-HPLC (reverse-phase high-performance liquid chromatography) method has been developed for the simultaneous estimation of perindopril erbumine and moxonidine hydrochloride, both used in hypertension treatment. Initially, a three-level factorial design screened various parameters impacting chromatographic responses, followed by Central Composite Design (CCD) for optimizing the critical parameters. This cost-effective isocratic method employed a Shimpack ODS C-18 column (250 mm × 4.6 mm, 5 μm) as the stationary phase. The method, developed and validated in line with ICH Q2 (R1) guidelines, utilized a mobile phase comprising methanol: acetonitrile: phosphate buffer (34:30:36 v/v/v) adjusted to pH 3.5 with 1% ortho phosphoric acid, at a flow rate of 1.0 mL/min, a column temperature of 40 ºC, and UV detection at 214 nm, achieving efficient separation of both drugs. Linearity ranges were 25–125 μg/mL for perindopril erbumine (r2 = 0.9996) and 1–5 μg/mL for moxonidine hydrochloride (r2 = 0.9993). This newly developed RP-HPLC method effectively enables routine quantitative and simultaneous qualitative analysis of these compounds in bulk and synthetic mixtures. Additionally, the method’s greenness and environmental safety were evaluated using eco-analytical metrics (eco analytical scale, NEMI, GAPI, and AGREE), confirming its ecological capability.
The combination of teneligliptin hydrobromide hydrate and pioglitazone hydrochloride in pharmaceutical formulations has improved type 2 diabetes management. Two chromatographic methods TLC-densitometry and RP-HPLC were developed for simultaneous quantification of teneligliptin hydrobromide hydrate and pioglitazone hydrochloride in pharmaceutical formulations, ensuring accuracy and stability assessment. The TLC method uses a mobile phase of methanol, toluene, ethyl acetate and triethylamine (1:7:2:0.1, v/v/v/v) on TLC silica gel plates, scanned at 268 nm. The RP-HPLC method employs isocratic elution with acetonitrile and sodium acetate buffer (adjust pH 3.6 with glacial acetic acid, 60:40 v/v) on a shimpack C18 column (250 × 4.6 mm i.d., 5 μm), detected at 235 nm. Both methods offer high accuracy and reliability, making them valuable for pharmaceutical quality control. Additionally, an environmental impact assessment was conducted using eco-scale, Analytical Greenness Metric Approach, Green Analytical Procedure Index, and national environmental method index to evaluate solvent consumption, waste generation and energy usage. Statistical comparisons (t-tests and F-tests) validate the outcomes of both methods, ensuring their effectiveness in drug formulation analysis. These methods can enhance pharmaceutical quality control while fulfilling environmental responsibilities.