Peter Dr. Nordbeck

Dr. Peter Dr. Nordbeck

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2017 in New England Journal of Medicine
Verified
Journal Article
Closed access
HTHolger Thiele
Holger Thiele
IAIbrahim Akin
Ibrahim Akin
MSMarcus Sandri
Marcus Sandri
GFGeorg Fuernau
Georg Fuernau
SWSuzanne de Waha
Suzanne de Waha
UZUwe Zeymer
Uwe Zeymer
In patients who have acute myocardial infarction with cardiogenic shock, early revascularization of the culprit artery by means of percutaneous coronary intervention (PCI) improves outcomes. However, the majority of patients with cardiogenic shock have multivessel disease, and whether PCI should be performed immediately for stenoses in nonculprit arteries is controversial.

1 December 2020 in Circulation
Verified
Journal Article
Open access
PDF file
BSBenedikt Schrage
Benedikt Schrage
PBPeter Moritz Becher
Peter Moritz Becher
ABAlexander Bernhardt
Alexander Bernhardt
HBHiram Bezerra
Hiram Bezerra
SBStefan Blankenberg
Stefan Blankenberg
DWDirk Westermann
Dirk Westermann
Background: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is increasingly used to treat cardiogenic shock. However, VA-ECMO might hamper myocardial recovery. The Impella unloads the left ventricle. This study aimed to evaluate whether left ventricular unloading in patients with cardiogenic shock treated with VA-ECMO was associated with lower mortality. Methods: Data from 686 consecutive patients with cardiogenic shock treated with VA-ECMO with or without left ventricular unloading using an Impella at 16 tertiary care centers in 4 countries were collected. The association between left ventricular unloading and 30-day mortality was assessed by Cox regression models in a 1:1 propensity score–matched cohort. Results: Left ventricular unloading was used in 337 of the 686 patients (49%). After matching, 255 patients with left ventricular unloading were compared with 255 patients without left ventricular unloading. In the matched cohort, left ventricular unloading was associated with lower 30-day mortality (hazard ratio, 0.79 [95% CI, 0.63–0.98]; P =0.03) without differences in various subgroups. Complications occurred more frequently in patients with left ventricular unloading: severe bleeding in 98 (38.4%) versus 45 (17.9%), access site–related ischemia in 55 (21.6%) versus 31 (12.3%), abdominal compartment in 23 (9.4%) versus 9 (3.7%), and renal replacement therapy in 148 (58.5%) versus 99 (39.1%). Conclusions: In this international, multicenter cohort study, left ventricular unloading was associated with lower mortality in patients with cardiogenic shock treated with VA-ECMO, despite higher complication rates. These findings support use of left ventricular unloading in patients with cardiogenic shock treated with VA-ECMO and call for further validation, ideally in a randomized, controlled trial.

1 November 2018 in New England Journal of Medicine
Verified
Journal Article
Closed access
PDF file
HTHolger Thiele
Holger Thiele
IAIbrahim Akin
Ibrahim Akin
MSMarcus Sandri
Marcus Sandri
SWSuzanne de Waha-Thiele
Suzanne de Waha-Thiele
RMRoza Meyer-Saraei
Roza Meyer-Saraei
SDSteffen Desch
Steffen Desch
Among patients with acute myocardial infarction, cardiogenic shock, and multivessel coronary artery disease, the risk of a composite of death from any cause or severe renal failure leading to renal-replacement therapy at 30 days was found to be lower with percutaneous coronary intervention (PCI) of the culprit lesion only than with immediate multivessel PCI. We evaluated clinical outcomes at 1 year. We randomly assigned 706 patients to either culprit-lesion-only PCI or immediate multivessel PCI. The results for the primary end point of death or renal-replacement therapy at 30 days have been reported previously. Prespecified secondary end points at 1 year included death from any cause, recurrent myocardial infarction, repeat revascularization, rehospitalization for congestive heart failure, the composite of death or recurrent infarction, and the composite of death, recurrent infarction, or rehospitalization for heart failure. As reported previously, at 30 days, the primary end point had occurred in 45.9% of the patients in the culprit-lesion-only PCI group and in 55.4% in the multivessel PCI group (P=0.01). At 1 year, death had occurred in 172 of 344 patients (50.0%) in the culprit-lesion-only PCI group and in 194 of 341 patients (56.9%) in the multivessel PCI group (relative risk, 0.88; 95% confidence interval [CI], 0.76 to 1.01). The rate of recurrent infarction was 1.7% with culprit-lesion-only PCI and 2.1% with multivessel PCI (relative risk, 0.85; 95% CI, 0.29 to 2.50), and the rate of a composite of death or recurrent infarction was 50.9% and 58.4%, respectively (relative risk, 0.87; 95% CI, 0.76 to 1.00). Repeat revascularization occurred more frequently with culprit-lesion-only PCI than with multivessel PCI (in 32.3% of the patients vs. 9.4%; relative risk, 3.44; 95% CI, 2.39 to 4.95), as did rehospitalization for heart failure (5.2% vs. 1.2%; relative risk, 4.46; 95% CI, 1.53 to 13.04). Among patients with acute myocardial infarction and cardiogenic shock, the risk of death or renal-replacement therapy at 30 days was lower with culprit-lesion-only PCI than with immediate multivessel PCI, and mortality did not differ significantly between the two groups at 1 year of follow-up. (Funded by the European Union Seventh Framework Program and others; CULPRIT-SHOCK ClinicalTrials.gov number, NCT01927549.)

8 January 2009 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
PNPeter Dr. Nordbeck
Peter Dr. Nordbeck
IWIngo Weiss
Ingo Weiss
PEPhilipp Ehses
Philipp Ehses
OROliver Ritter
Oliver Ritter
MWMarcus Warmuth
Marcus Warmuth
WBWolfgang R. Bauer
Wolfgang R. Bauer
Radiofrequency (RF)‐related heating of cardiac pacemaker leads is a serious concern in magnetic resonance imaging (MRI). Recent investigations suggest such heating to be strongly dependent on an implant's position within the surrounding medium, but this issue is currently poorly understood. In this study, phantom measurements of the RF‐induced electric currents inside a pacemaker lead were performed to investigate the impact of the device position and lead configuration on the amount of MRI‐related heating at the lead tip. Seven hundred twenty device position/lead path configurations were investigated. The results show that certain configurations are associated with a highly increased risk to develop MRI‐induced heating, whereas various configurations do not show any significant heating. It was possible to precisely infer implant heating on the basis of current intensity values measured inside a pacemaker lead. Device position and lead configuration relative to the surrounding medium are crucial to the amount of RF‐induced heating in MRI. This indicates that a considerable number of implanted devices may incidentally not develop severe heating in MRI because of their specific configuration in the body. Small variations in configuration can, however, strongly increase the risk for such heating effects, meaning that hazardous situations might appear during MRI. Magn Reson Med, 2009.

7 March 2006 in Circulation
Verified
Journal Article
Closed access
PDF file
MNMatthias Nahrendorf
Matthias Nahrendorf
KHKai Hu
Kai Hu
SFStefan Frantz
Stefan Frantz
FJFarouc A Jaffer
Farouc A Jaffer
CTChing Tung
Ching Tung
GEGeorg Ertl
Georg Ertl
Background— Identification of key molecular players in myocardial healing could lead to improved therapies, reduction of scar formation, and heart failure after myocardial infarction (MI). We hypothesized that clotting factor XIII (FXIII), a transglutaminase involved in wound healing, may play an important role in MI given prior clinical and mouse model data. Methods and Results— To determine whether a truly causative relationship existed between FXIII activity and myocardial healing, we prospectively studied myocardial repair in FXIII-deficient mice. All FXIII −/− and FXIII − /+ (FXIII activity <5% and 70%) mice died within 5 days after MI from left ventricular rupture. In contradistinction, FXIII −/− mice that received 5 days of intravenous FXIII replacement therapy had normal survival rates; however, cardiac MRI demonstrated worse left ventricular remodeling in these reconstituted FXIII −/− mice. Using a FXIII-sensitive molecular imaging agent, we found significantly greater FXIII activity in wild-type mice and FXIII −/− mice receiving supplemental FXIII than in FXIII −/− mice ( P <0.05). In FXIII −/− but not in reconstituted FXIII −/− mice, histology revealed diminished neutrophil migration into the MI. Reverse transcriptase–polymerase chain reaction studies suggested that the impaired inflammatory response in FXIII −/− mice was independent of intercellular adhesion molecule and lipopolysaccharide-induced CXC chemokine, both important for cell migration. After MI, expression of matrix metalloproteinase-9 was 650% higher and collagen-1 was 53% lower in FXIII −/− mice, establishing an imbalance in extracellular matrix turnover and providing a possible mechanism for the observed cardiac rupture in the FXIII −/− mice. Conclusions— These data suggest that FXIII has an important role in murine myocardial healing after infarction.

29 July 2008 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
PNPeter Dr. Nordbeck
Peter Dr. Nordbeck
FFFlorian Fidler
Florian Fidler
IWIngo Weiss
Ingo Weiss
MWMarcus Warmuth
Marcus Warmuth
MFMichael T. Friedrich
Michael T. Friedrich
WBWolfgang R. Bauer
Wolfgang R. Bauer
The purpose of this study was to assess the distribution of RF‐induced E‐fields inside a gel‐filled phantom of the human head and torso and compare the results with the RF‐induced temperature rise at the tip of a straight conductive implant, specifically examining the dependence of the temperature rise on the position of the implant inside the gel. MRI experiments were performed in two different 1.5T MR systems of the same manufacturer. E‐field distribution inside the liquid was assessed using a custom measurement system. The temperature rise at the implant tip was measured in various implant positions and orientations using fluoroptic thermometry. The results show that local E‐field strength in the direction of the implant is a critical factor in RF‐related tissue heating. The actual E‐field distribution, which is dependent on phantom/body properties and the MR‐system employed, must be considered when assessing the effects of RF power deposition in implant safety investigations. Magn Reson Med 60:312–319, 2008.