Rossano Girometti

Prof. Rossano Girometti


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2024 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
BKBurak Kocak
Burak Kocak
TDTugba Akinci D'Antonoli
Tugba Akinci D'Antonoli
NMNathaniel Mercaldo
Nathaniel Mercaldo
AAAngel Alberich-Bayarri
Angel Alberich-Bayarri
BBBettina Baeßler
Bettina Baeßler
Renato CuocoloRenato Cuocolo
Renato Cuocolo
Purpose: To propose a new quality scoring tool, METhodological RadiomICs Score (METRICS), to assess and improve research quality of radiomics studies. Methods: We conducted an online modified Delphi study with a group of international experts. It was performed in three consecutive stages: Stage#1, item preparation; Stage#2, panel discussion among EuSoMII Auditing Group members to identify the items to be voted; and Stage#3, four rounds of the modified Delphi exercise by panelists to determine the items eligible for the METRICS and their weights. The consensus threshold was 75%. Based on the median ranks derived from expert panel opinion and their rank-sum based conversion to importance scores, the category and item weights were calculated. Result: In total, 59 panelists from 19 countries participated in selection and ranking of the items and categories. Final METRICS tool included 30 items within 9 categories. According to their weights, the categories were in descending order of importance: study design, imaging data, image processing and feature extraction, metrics and comparison, testing, feature processing, preparation for modeling, segmentation, and open science. A web application and a repository were developed to streamline the calculation of the METRICS score and to collect feedback from the radiomics community. Conclusion: In this work, we developed a scoring tool for assessing the methodological quality of the radiomics research, with a large international panel and a modified Delphi protocol. With its conditional format to cover methodological variations, it provides a well-constructed framework for the key methodological concepts to assess the quality of radiomic research papers. Critical relevance statement: A quality assessment tool, METhodological RadiomICs Score (METRICS), is made available by a large group of international domain experts, with transparent methodology, aiming at evaluating and improving research quality in radiomics and machine learning. Key points: • A methodological scoring tool, METRICS, was developed for assessing the quality of radiomics research, with a large international expert panel and a modified Delphi protocol. • The proposed scoring tool presents expert opinion-based importance weights of categories and items with a transparent methodology for the first time. • METRICS accounts for varying use cases, from handcrafted radiomics to entirely deep learning-based pipelines. • A web application has been developed to help with the calculation of the METRICS score (https://metricsscore.github.io/metrics/METRICS.html) and a repository created to collect feedback from the radiomics community (https://github.com/metricsscore/metrics). Graphical

1 November 2006 in RadioGraphics
Verified
Journal Article
Closed access
CFChiara Del Frate
Chiara Del Frate
RGRossano Girometti
Rossano Girometti
MPMarco Pittino
Marco Pittino
GFGiovanni Del Frate
Giovanni Del Frate
MBMassimo Bazzocchi
Massimo Bazzocchi
CZChiara Zuiani
Chiara Zuiani
Deep pelvic endometriosis is defined as subperitoneal infiltration of endometrial implants in the uterosacral ligaments, rectum, rectovaginal septum, vagina, or bladder. It is responsible for severe pelvic pain. Accurate preoperative assessment of disease extension is required for planning complete surgical excision, but such assessment is difficult with physical examination. Various sonographic approaches (transvaginal, transrectal, endoscopic transrectal) have been used for this purpose but do not allow panoramic evaluation. Furthermore, exploratory laparoscopy has limitations in demonstrating deep endometriotic lesions hidden by adhesions or located in the subperitoneal space. Despite some limitations, magnetic resonance (MR) imaging is able to directly demonstrate deep pelvic endometriosis. The MR imaging features depend on the type of lesions: infiltrating small implants, solid deep lesions mainly located in the posterior cul-de-sac and involving the uterosacral ligaments and torus uterinus, or visceral endometriosis involving the bladder and rectal wall. Solid deep lesions have low to intermediate signal intensity with punctate regions of high signal intensity on T1-weighted images, show uniform low signal intensity on T2-weighted images, and can demonstrate enhancement on contrast-enhanced images. MR imaging is a useful adjunct to physical examination and transvaginal or transrectal sonography in evaluation of patients with deep infiltrating endometriosis.

16 May 2010 in Abdominal Radiology
Verified
Journal Article
Closed access
PDF file
RGRossano Girometti
Rossano Girometti
SISergio Intini
Sergio Intini
GBGiovanni Brondani
Giovanni Brondani
GCGiuseppe Como
Giuseppe Como
FLFrancesco Londero
Francesco Londero
MBMassimo Bazzocchi
Massimo Bazzocchi

20 April 2007 in La radiologia medica
Verified
Journal Article
Closed access
PDF file
RGRossano Girometti
Rossano Girometti
AFA. Furlan
A. Furlan
MBM. Bazzocchi
M. Bazzocchi
FSF. Soldano
F. Soldano
MIM. Isola
M. Isola
CZC. Zuiani
C. Zuiani

29 July 2008 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
RGRossano Girometti
Rossano Girometti
AFAlessandro Furlan
Alessandro Furlan
GEGennaro Esposito
Gennaro Esposito
MBMassimo Bazzocchi
Massimo Bazzocchi
GCGiuseppe Como
Giuseppe Como
CZChiara Zuiani
Chiara Zuiani
Purpose To investigate the relevance of increasing b‐values in evaluating liver fibrosis through the agreement of two diffusion‐weighted (DW) sequences. Materials and Methods A total of 29 cirrhotic patients and 29 healthy volunteers were studied on a 1.5T system. Two single‐shot spin‐echo echo‐planar sequences were acquired using sets of increasing b‐values: 0, 150, 250, and 400 seconds/mm2 (first sequence: DW1a) and 0, 150, 250, 400, 600, and 800 seconds/mm2 (second sequence: DW2a). Apparent diffusion coefficients (ADCs) of the hepatic parenchyma were calculated on ADC maps. Noise‐scaled single‐point ADCs were calculated for each sequence from b = 400 seconds/mm2. Results ADCs resulted significantly lower in cirrhotic patients compared to controls using both DW1a (mean 1.14 ± 0.20 × 10−3mm2/second vs. 1.54 ± 0.12 × 10−3mm2/second; P < 0.0001) and DW2a (mean 0.91 ± 0.18 × 10−3mm2/second vs. 1.04 ± 0.18 × 10−3mm2/second; P = 0.0089). DW1 and DW2, respectively significantly differed in diagnostic performance at receiver operating characteristic (ROC) curve analysis (P = 0.003), showing AUCs of 0.93 (sensitivity 89.7%, specificity 100%) and 0.73 (sensitivity 62.1%, specificity 79.3%), respectively. Noise‐scaled single‐point ADCs showed a progressive convergence to similar values in cirrhotic and healthy livers at b = 800 seconds/mm2 (1.12 ± 0.27 × 10−3mm2/second vs. 1.13 ± 0.17 × 10−3mm2/second). Conclusion A DW sequence is accurate in assessing liver fibrosis using intermediate (400 seconds/mm2) rather than high (800 seconds/mm2) maximum b‐values, but after proper recalculation of ADCs the effects of perfusion rather than diffusion should be considered responsible for the higher accuracy at lower b‐values. J. Magn. Reson. Imaging 2008;28:411–419.

1 April 2010 in American Journal of Roentgenology
Verified
Journal Article
Closed access
ALAnna Linda
Anna Linda
CZChiara Zuiani
Chiara Zuiani
AFAlessandro Furlan
Alessandro Furlan
VLViviana Londero
Viviana Londero
RGRossano Girometti
Rossano Girometti
MBMassimo Bazzocchi
Massimo Bazzocchi
OBJECTIVE. The purposes of our study were to evaluate the surgical outcome of cases of radial scar without atypia diagnosed at imaging-guided percutaneous needle biopsy and to determine whether the mammographic and sonographic features are able to predict which lesions will be upgraded to malignancy at surgical excision.MATERIALS AND METHODS. The records of 4,458 consecutive imaging-guided biopsies were retrospectively reviewed. Surgical excision results were available in 62 cases in which radial scar was the highest-risk lesion at stereotactically guided or sonographically guided biopsy. The mammographic and sonographic images and surgical findings were reviewed. The underestimation rate of malignancy of percutaneous biopsy was calculated. Differences in mammographic and sonographic appearances between radial scars with and without associated malignancy were evaluated using the Fisher's exact test.RESULTS. The percutaneous malignancy underestimation rate was 8% (5/62): 9% (4/43) for sonography guided 14-...