Xiangguo Xu

Dr. Xiangguo Xu

Institute of Refrigeration and Cryogenics, College of Energy Engineering, Zhejiang University, Hangzhou 310027, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2024 in International Journal of Refrigeration
Verified
Journal Article
Closed access
NXNing Xu
Ning Xu
CYChongyang Ye
Chongyang Ye
YHYongjun Hu
Yongjun Hu
JSJunqiang Shao
Junqiang Shao
Xiangguo XuXiangguo Xu
Xiangguo Xu
JWJianjian Wei
Jianjian Wei

19 December 2023 in Energy and Buildings
Verified
Journal Article
Closed access
YZYulin Zheng
Yulin Zheng
Xiangguo XuXiangguo Xu
Xiangguo Xu

3 February 2023 in Energy Conversion and Management: X
Verified
Journal Article
Open access
Xiangguo XuXiangguo Xu
Xiangguo Xu
ZZZhe Zhang
Zhe Zhang
JYJiawei Yuan
Jiawei Yuan
JSJunqiang Shao
Junqiang Shao

29 January 2019 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
SWShikuan Wang
Shikuan Wang
ZGZhikai Guo
Zhikai Guo
Xiaohong HanXiaohong Han
Xiaohong Han
Xiangguo XuXiangguo Xu
Xiangguo Xu
QWQin Wang
Qin Wang
GCGuangming Chen
Guangming Chen
HFO-1336mzz-Z with low global warming potential (GWP) was considered as a promising alternative of HCFC-123, HFC-245fa in air conditioning (AC) and heat pump (HP), respectively. In order to understand the operation performances of HFO-1336mzz-Z and HCFC-123, HFC-245fa in different working conditions, an experimental setup for testing the refrigeration cycle performance was built. The cycle performances of HFO-1336mzz-Z and HCFC-123 in AC conditions, HFO-1336mzz-Z and HFC-245fa in HP conditions were investigated by experiment. It was found in AC conditions, the discharge temperatures for the systems with HFO-1336mzz-Z and HCFC-123 were lower than 115 °C, the cooling capacity of the system with HFO-1336mzz-Z was 27% less than that with HCFC-123 at least, and the coefficient of performance (COP) of the system with HFO-1336mzz-Z was 0.1 lower than that with HCFC-123; in HP conditions, the discharge temperature with HFO-1336mzz-Z was lower than that with HFC-245fa, the former was never over 115 °C while the latter was up to 126 °C, the power input to the compressor with HFO-1336mzz-Z was 20% less than that with HFC-245fa in the same HP conditions, the heating capacity of the system with HFO-1336mzz-Z was 30–40% less than that with HFC-245fa.


17 December 2014 in Building Services Engineering Research & Technology
Verified
Journal Article
Closed access
QWQ Wang
Q Wang
BRB Ren
B Ren
ZZZy Zeng
Zy Zeng
WHW He
W He
YLYq Liu
Yq Liu
GCGm Chen
Gm Chen
A novel indirect-expansion solar-assisted multifunctional heat pump with four heat exchangers was proposed in this paper, which integrates a heat pump air conditioner, a solar water heater and a heat pump water heater. In addition to these three basic operation modes, it also provided five energy-saving operation modes, which resulted in a higher utilization ratio of the solar energy and lower operational cost. Experiments of the solar-assisted space heating mode, air source heat pump water heating mode and solar-assisted heat pump water heating mode have been investigated in detail at different outdoor temperatures and different water temperatures. The novel indirect-expansion solar-assisted multifunctional heat pump is especially suitable for the regions abundant in solar radiation where the space heating, space cooling and water heating are required all the year round. Practical applications: The novel IX-SAMHP can provide space cooling, space heating, hot water by one system. The space used for those appliances can be reduced effectively. Solar energy was used to assist the space heating and water heating and defrost process and it can save the energy consumption efficiently.