Ehsan Najafi

Dr. Ehsan Najafi

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2011 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ENEhsan Najafi
Ehsan Najafi
AYAbdul Halim Mohamed Yatim
Abdul Halim Mohamed Yatim
Multilevel inverters have been widely accepted for high-power high-voltage applications. Their performance is highly superior to that of conventional two-level inverters due to reduced harmonic distortion, lower electromagnetic interference, and higher dc link voltages. However, it has some disadvantages such as increased number of components, complex pulsewidth modulation control method, and voltage-balancing problem. In this paper, a new topology with a reversing-voltage component is proposed to improve the multilevel performance by compensating the disadvantages mentioned. This topology requires fewer components compared to existing inverters (particularly in higher levels) and requires fewer carrier signals and gate drives. Therefore, the overall cost and complexity are greatly reduced particularly for higher output voltage levels. Finally, a prototype of the seven-level proposed topology is built and tested to show the performance of the inverter by experimental results.

8 January 2011 in Energy Conversion and Management
Verified
Journal Article
Closed access
ENEhsan Najafi
Ehsan Najafi
AYA.H.M. Yatim
A.H.M. Yatim

6 February 2019 in International Journal of Circuit Theory and Applications
Verified
Journal Article
Closed access
PDF file
AMAmin Mirzaei
Amin Mirzaei
MRMahdi Rezvanyvardom
Mahdi Rezvanyvardom
ENEhsan Najafi
Ehsan Najafi

1 December 2008
Verified
Conference Paper
Closed access
ENEhsan Najafi
Ehsan Najafi
AYA. H. M. Yatim
A. H. M. Yatim
ASA. S. Samosir
A. S. Samosir
Multi level inverters have been widely accepted for high power high voltage applications. Their performance is highly superior to conventional two level inverters in reduced harmonic distortion, lower EMI (electro magnetic interference) and higher DC link voltages. However it has some disadvantages as increased number of components, complicated PWM control method, and voltage balancing problem at neutral point. In this paper a new topology called reversing voltage (RV) is proposed to improve the multi level performance by compensating the disadvantages already mentioned. This topology requires less components compared to available inverters (especially in higher levels) and requires less carrier signals and does not need balancing of the voltages. The topology and the control method based on PD (phase disposition) SPWM are shown and the required components are also compared to other topologies to show the superiority of the topology. Finally, output voltage and currents are demonstrated by simulation.

21 October 2022 in IEEE Transactions on Intelligent Transportation Systems
Verified
Journal Article
Closed access
SHSaeed Hasanzadeh
Saeed Hasanzadeh
SZSeyed Fariborz Zarei
Seyed Fariborz Zarei
ENEhsan Najafi
Ehsan Najafi
Energy efficiency is one of the main issues in designing and operating different electrical systems. Energy-saving in electrical railway systems is an important concern due to the high amount of used energy. In order to find optimum energy consumption, different methodologies shall be examined. In addition, various affecting factors should be determined, and suitable solutions should be adopted. This paper illustrates that proper train scheduling is one of the effective approaches to optimize the system energy. Accordingly, comprehensive modeling is proposed considering different affecting factors such as the slope of different lines, the speed limits in each section, the time limit between the arrivals of trains to each station, and different modes of operation such as motoring and braking. Using the proposed model, an optimization problem with the objective function of energy-saving is solved. To evaluate the effectiveness of the proposed method, the proposed scheduling scheme is applied to Line 2 of Tehran Urban & Suburban Railway Operation Company. Based on the results, using the proposed scheme causes a 3.2% energy-saving compared to the existing train movement schedule in the same line. The proposed train movement scheduling program is proceeding to the last verification steps and will be used as a part of Tehran Metro navigation system in the near future.

1 January 2018
Verified
Book Chapter
Closed access
Natarajan PrabaharanNatarajan Prabaharan
Natarajan Prabaharan
AJAmalorpavaraj Rini Ann Jerin
Amalorpavaraj Rini Ann Jerin
ENEhsan Najafi
Ehsan Najafi
KPKaliannan Palanisamy
Kaliannan Palanisamy