Barry Cense

Dr. Barry Cense


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2003 in Optics Letters
Verified
Journal Article
Closed access
PDF file
JBJohannes F. de Boer
Johannes F. de Boer
BCBarry Cense
Barry Cense
BPB. Hyle Park
B. Hyle Park
MPMark Pierce
Mark Pierce
GTGuillermo J. Tearney
Guillermo J. Tearney
BBBrett E. Bouma
Brett E. Bouma
A signal-to-noise ratio (SNR) analysis is presented for optical coherence tomography (OCT) signals in which time-domain performance is compared with that of the spectral domain. A significant SNR gain of several hundredfold is found for acquisition in the spectral domain. The SNR benefit is demonstrated experimentally in a hybrid time-domain–spectral-domain OCT system.

9 February 2004 in Optics Express
Verified
Journal Article
Closed access
PDF file
NNN. A. Nassif
N. A. Nassif
BCBarry Cense
Barry Cense
BPB. H. Park
B. H. Park
MPM. C. Pierce
M. C. Pierce
SYS. H. Yun
S. H. Yun
JBJ. F. de Boer
J. F. de Boer
An ultra-high-speed spectral-domain optical coherence tomography system (SD-OCT) was developed for imaging the human retina and optic nerve in vivo at a sustained depth profile (A-line) acquisition speed of 29 kHz. The axial resolution was 6 µm in tissue and the system had shot-noise-limited performance with a maximum sensitivity of 98.4 dB. 3-dimensional data sets were collected in 11 and 13 seconds for the macula and optic nerve head respectively and are presented to demonstrate the potential clinical applications of SD-OCT in ophthalmology. Additionally, a 3-D volume of the optic nerve head was constructed from the acquired data and the retinal vascular network was visualized.

1 March 2004 in Optics Letters
Verified
Journal Article
Closed access
PDF file
NNNader Nassif
Nader Nassif
BCBarry Cense
Barry Cense
BPB. Hyle Park
B. Hyle Park
SYSeok H. Yun
Seok H. Yun
TCTeresa C. Chen
Teresa C. Chen
JBJohannes F. de Boer
Johannes F. de Boer
An ultrahigh-speed spectral domain optical coherence tomography (SD-OCT) system is presented that achieves acquisition rates of 29,300 depth profiles/s. The sensitivity of SD-OCT and time domain OCT (TD-OCT) are experimentally compared, demonstrating a 21.7-dB improvement of SD-OCT over TD-OCT. In vivo images of the human retina are presented, demonstrating the ability to acquire high-quality structural images with an axial resolution of 6 µm at ultrahigh speed and with an ocular exposure level of less than 600 µW.

31 May 2004 in Optics Express
Verified
Journal Article
Closed access
PDF file
BCBarry Cense
Barry Cense
NNNader A. Nassif
Nader A. Nassif
TCTeresa C. Chen
Teresa C. Chen
MPMark Pierce
Mark Pierce
SYSeok-Hyun Yun
Seok-Hyun Yun
JBJohannes F. de Boer
Johannes F. de Boer
We present the first ultrahigh-resolution optical coherence tomography (OCT) structural intensity images and movies of the human retina in vivo at 29.3 frames per second with 500 A-lines per frame. Data was acquired at a continuous rate of 29,300 spectra per second with a 98% duty cycle. Two consecutive spectra were coherently summed to improve sensitivity, resulting in an effective rate of 14,600 A-lines per second at an effective integration time of 68 µs. The turn-key source was a combination of two super luminescent diodes with a combined spectral width of more than 150 nm providing 4.5 mW of power. The spectrometer of the spectral-domain OCT (SD-OCT) setup was centered around 885 nm with a bandwidth of 145 nm. The effective bandwidth in the eye was limited to approximately 100 nm due to increased absorption of wavelengths above 920 nm in the vitreous. Comparing the performance of our ultrahighresolution SD-OCT system with a conventional high-resolution time domain OCT system, the A-line rate of the spectral-domain OCT system was 59 times higher at a 5.4 dB lower sensitivity. With use of a software based dispersion compensation scheme, coherence length broadening due to dispersion mismatch between sample and reference arms was minimized. The coherence length measured from a mirror in air was equal to 4.0 µm (n=1). The coherence length determined from the specular reflection of the foveal umbo in vivo in a healthy human eye was equal to 3.5 µm (n=1.38). With this new system, two layers at the location of the retinal pigmented epithelium seem to be present, as well as small features in the inner and outer plexiform layers, which are believed to be small blood vessels.

15 December 2003 in Optics Express
Verified
Journal Article
Open access
PDF file
BWBrian R. White
Brian R. White
MPMark Pierce
Mark Pierce
NNNader Nassif
Nader Nassif
BCBarry Cense
Barry Cense
BPB. Hyle Park
B. Hyle Park
JBJohannes F. de Boer
Johannes F. de Boer
An ultra-high-speed spectral domain optical Doppler tomography (SD-ODT) system is used to acquire images of blood flow in a human retina in vivo, at 29,000 depth profiles (A-lines) per second and with data acquisition over 99% of the measurement time. The phase stability of the system is examined and image processing algorithms are presented that allow accurate determination of bi-directional Doppler shifts. Movies are presented of human retinal flow acquired at 29 frames per second with 1000 A-lines per frame over a time period of 3.28 seconds, showing accurate determination of vessel boundaries and time-dependent bi-directional flow dynamics in artery-vein pairs. The ultra-high-speed SD-ODT system allows visualization of the pulsatile nature of retinal blood flow, detects blood flow within the choroid and retinal capillaries, and provides information on the cardiac cycle. In summary, accurate video rate imaging of retinal blood flow dynamics is demonstrated at ocular exposure levels below 600 µW.

1 December 2005 in Archives of Ophthalmology (1950)
Verified
Journal Article
Closed access
PDF file
TCTeresa C. Chen
Teresa C. Chen
BCBarry Cense
Barry Cense
MPMark Pierce
Mark Pierce
NNNader Nassif
Nader Nassif
BPB. Hyle Park
B. Hyle Park
JBJohannes F. de Boer
Johannes F. de Boer
Objective To introduce a new ophthalmic optical coherence tomography technology that allows unprecedented simultaneous ultra-high speed and ultra-high resolution. Methods Using a superluminescent diode source, a clinically viable ultra-high speed, ultra-high resolution spectral domain optical coherence tomography system was developed. Results In vivo images of the retina, the optic nerve head, and retinal blood flow were obtained at an ultra-high speed of 34.1 microseconds (ms) per A-scan, which is 73 times faster than commercially available optical coherence tomography instruments. Single images (B-scans) consisting of 1000 A-scans were acquired in 34.1 ms, allowing video rate imaging at 29 frames per second with an axial resolution of 6 μm. Using a different source in a slightly slower configuration, single images consisting of 500 A-scans were acquired in 34 ms, allowing imaging at 29 frames per second at an axial resolution of 3.5 μm, which is 3 times better than commercially available optical coherence tomography instruments. The amount of energy directed into the eye in both cases, 600 μW, is less than that of the Stratus OCT3 and is safe for intrabeam viewing for up to 8 hours at the same retinal location. Conclusion Spectral domain optical coherence tomography technology enables ophthalmic imaging with unprecedented simultaneous ultra-high speed and ultra-high resolution.