Alexander D. Kashin

Mr. Alexander D. Kashin

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2022 in Ceramics International
Verified
Journal Article
Closed access
AKAlexander D. Kashin
Alexander D. Kashin
Mariya SedelnikovaMariya Sedelnikova
Mariya Sedelnikova
VCValentina Vadimovna Chebodaeva
Valentina Vadimovna Chebodaeva
PUPavel V. Uvarkin
Pavel V. Uvarkin
NLN.A. Luginin
N.A. Luginin
OBO.V. Bakina
O.V. Bakina

15 March 2024 in Polymers
Verified
Journal Article
Open access
PDF file
KPKonstantin Prosolov
Konstantin Prosolov
Ekaterina G. KomarovaEkaterina G. Komarova
Ekaterina G. Komarova
EKEkaterina Kazantseva
Ekaterina Kazantseva
NLNikita Luginin
Nikita Luginin
AKAlexander D. Kashin
Alexander D. Kashin
Yurii SharkeevYurii Sharkeev
Yurii Sharkeev
In addressing the challenge of enhancing orthopedic implants, 3D porous calcium phosphate (CaP) coatings on titanium (Ti) substrates modified with poly(lactic-co-glycolic acid) (PLGA) were proposed. CaP coatings on Ti were deposited using the ultrasonic-assisted micro-arc oxidation (UMAO) method, followed by modification with PLGA through a dip coating process at concentrations of 5%, 8%, and 10%. The addition of PLGA significantly improved adhesive–cohesive strength according to the scratch test, while PLGA to CaP adhesion was found to be not less than 8.1 ± 2.2 MPa according to the peel test. Tensile testing showed a typical fracture of CaP coatings and mechanisms of brittle fracture. Corrosion resistance, assessed via gravimetric and electrochemical methods in 0.9% NaCl and PBS solutions, revealed PLGA’s substantial reduction in corrosion rates, with the corrosion current decreasing by two orders of magnitude even for the 5% PLGA/CaP/Ti sample. Also, the PLGA layer significantly enhanced the impedance modulus by two orders of magnitude, indicating a robust barrier against corrosion at all PLGA concentrations. Higher PLGA concentrations offered even greater corrosion resistance and improved mechanical properties. This research underscores the potential of using CaP- and PLGA-modified coatings to extend the life and functionality of orthopedic implants, addressing a significant challenge in biomedical engineering.

15 November 2022 in Materials Chemistry and Physics
Verified
Journal Article
Closed access
Mariya SedelnikovaMariya Sedelnikova
Mariya Sedelnikova
KIKonstantin Ivanov
Konstantin Ivanov
AUA.V. Ugodchikova
A.V. Ugodchikova
AKAlexander D. Kashin
Alexander D. Kashin
PUPavel V. Uvarkin
Pavel V. Uvarkin
AGAndrey S. Gnedenkov
Andrey S. Gnedenkov

29 June 2023 in Biomimetics
Verified
Journal Article
Open access
PDF file
AKAlexander D. Kashin
Alexander D. Kashin
Mariya SedelnikovaMariya Sedelnikova
Mariya Sedelnikova
PUPavel V. Uvarkin
Pavel V. Uvarkin
AUAnna V. Ugodchikova
Anna V. Ugodchikova
NLNikita Luginin
Nikita Luginin
OBOlga Vladimirovna Bakina
Olga Vladimirovna Bakina
The method of micro-arc oxidation has been utilized to synthesize a protective biocompatible coating for a bioresorbable orthopedic Mg implant. This paper presents the results of comprehensive research of micro-arc coatings based on diatomite—a biogenic material consisting of shells of diatom microalgae. The main focus of this study was the functionalization of diatomite-based micro-arc coatings by incorporating particles of titania (TiO2) into them. Various properties of the resulting coatings were examined and evaluated. XRD analysis revealed the formation of a new magnesium orthosilicate phase—forsterite (Mg2SiO4). It was established that the corrosion current density of the coatings decreased by 1–2 orders of magnitude after the inclusion of TiO2 particles, depending on the coating process voltage. The adhesion strength of the coatings increased following the particle incorporation. The processes of dissolution of both coated and uncoated samples in a sodium chloride solution were studied. The in vitro cell viability was assessed, which showed that the coatings significantly reduced the cytotoxicity of Mg samples.

30 September 2022 in Metals
Verified
Journal Article
Open access
PDF file
Mariya SedelnikovaMariya Sedelnikova
Mariya Sedelnikova
OBOlga Vladimirovna Bakina
Olga Vladimirovna Bakina
AUAnna Ugodchikova
Anna Ugodchikova
TTTatiana Tolkacheva
Tatiana Tolkacheva
MKMargarita A. Khimich
Margarita A. Khimich
Yurii SharkeevYurii Sharkeev
Yurii Sharkeev
The introduction of particles into the composition of coatings can significantly expand the range of properties and possibilities of the modified materials. In this work, the coatings containing microparticles of β-tricalcium phosphate (β-TCP) and wollastonite separately and in combination with each other were created on the surface of an Mg0.8Ca alloy. The morphology and microstructure of the coatings were examined by scanning and transmission electron microscopy. Their phase composition was determined with the help of X-ray diffraction analysis. The coating-to-substrate adhesion evaluation was carried out via the scratch-test method. Potentiodynamic polarization curves of the coatings were obtained during their immersion in 0.9% NaCl solution and their electrochemical properties were determined. Cytotoxic properties of the coatings were investigated by means of the MTT assay and flow cytometry in the course of the biological studies. In addition, NIH/3T3 cell morphology was analyzed using scanning electron microscopy. The structure, morphology, physical and mechanical, corrosive, and biological properties of the coatings depended on the type of particles they contained. Whereas the coating with β-TCP microparticles had higher adhesive properties, the coatings with wollastonite microparticles, as well as the combined coating, were less soluble and more biocompatible. In addition, the wollastonite-containing coating had the highest corrosion resistance.

Verified
Journal Article
Open access
PDF file
Mariya SedelnikovaMariya Sedelnikova
Mariya Sedelnikova
AKAlexander D. Kashin
Alexander D. Kashin
PUPavel V. Uvarkin
Pavel V. Uvarkin
ATAlexey I. Tolmachev
Alexey I. Tolmachev
Yurii SharkeevYurii Sharkeev
Yurii Sharkeev
OBOlga Vladimirovna Bakina
Olga Vladimirovna Bakina
In the present work, the surface of a biodegradable Mg alloy was modified to create porous diatomite biocoatings using the method of micro-arc oxidation. The coatings were applied at process voltages in the range of 350–500 V. We have studied the influence of the addition of ZrO2 microparticles on the structure and properties of diatomite-based protective coatings for Mg implants. The structure and properties of the resulting coatings were examined using a number of research methods. It was found that the coatings have a porous structure and contain ZrO2 particles. The coatings were mostly characterized by pores less than 1 μm in size. However, as the voltage of the MAO process increases, the number of larger pores (5–10 μm in size) also increases. However, the porosity of the coatings varied insignificantly and amounted to 5 ± 1%. It has been revealed that the incorporation of ZrO2 particles substantially affects the properties of diatomite-based coatings. The adhesive strength of the coatings has increased by approximately 30%, and the corrosion resistance has increased by two orders of magnitude compared to the coatings without zirconia particles.