A review of vagus nerve stimulation as a therapeutic intervention Rhaya L Johnson,1 Christopher G Wilson1,2 1Lawrence D Longo MD Center for Perinatal Biology, Department of Basic Sciences, Loma Linda University, Loma Linda, CA, USA; 2Department of Pediatrics, Loma Linda University, Loma Linda, CA, USA In this review, we provide an overview of the US Food and Drug Administration (FDA)-approved clinical uses of vagus nerve stimulation (VNS) as well as information about the ongoing studies and preclinical research to expand the use of VNS to additional applications. VNS is currently FDA approved for therapeutic use in patients aged >12 years with drug-resistant epilepsy and depression. Recent studies of VNS in in vivo systems have shown that it has anti-inflammatory properties which has led to more preclinical research aimed at expanding VNS treatment across a wider range of inflammatory disorders. Although the signaling pathway and mechanism by which VNS affects inflammation remain unknown, VNS has shown promising results in treating chronic inflammatory disorders such as sepsis, lung injury, rheumatoid arthritis (RA), and diabetes. It is also being used to control pain in fibromyalgia and migraines. This new preclinical research shows that VNS bears the promise of being applied to a wider range of therapeutic applications. Keywords: vagus nerve stimulation, pediatrics, inflammation, peripheral nerve stimulation, autonomic circuits
1 July 2016 in Respiratory Physiology & Neurobiology
Understanding hypoxia/hyperoxia exposure requires either a high-altitude research facility or a chamber in which gas concentrations are precisely and reproducibly controlled. Hypoxia-induced conditions such as hypoxic-ischemic encephalopathy (HIE), obstructive or central apneas, and ischemic stroke present unique challenges for the development of models with acute or chronic hypoxia exposure. Many murine models exist to study these conditions; however, there are a variety of different hypoxia exposure protocols used across laboratories. Experimental equipment for hypoxia exposure typically includes flow regulators, nitrogen concentrators, and premix oxygen/nitrogen tanks. Commercial hypoxia/hyperoxia chambers with environmental monitoring are incredibly expensive and require proprietary software with subscription fees or highly expensive software licenses. Limitations exist in these systems as most are single animal systems and not designed for extended or intermittent hypoxia exposure. We have developed a simple hypoxia chamber with off-the-shelf components, and controlled by open-source software for continuous data acquisition of oxygen levels and other environmental factors (temperature, humidity, pressure, light, sound, etc.). Our chamber can accommodate up to two mouse cages and one rat cage at any oxygen level needed, when using a nitrogen concentrator or premixed oxygen/nitrogen tank with a flow regulator, but is also scalable. Our system uses a Python-based script to save data in a text file using modules from the sensor vendor. We utilized Python or R scripts for data analysis, and we have provided examples of data analysis scripts and acquired data for extended exposure periods (≤7 days). By using FLOS (Free-Libre and open-source) software and hardware, we have developed a low-cost and customizable system that can be used for a variety of exposure protocols. This hypoxia/hyperoxia exposure chamber allows for reproducible and transparent data acquisition and increased consistency with a high degree of customization for each experimenter’s needs.
25 July 2019 in Respiratory Physiology & Neurobiology
Vagus nerve stimulation (VNS) is an Food and Drug Administration-approved method delivering electrical impulses for treatment of depression and epilepsy in adults. The vagus nerve innervates the majority of visceral organs and cervix, but potential impacts of VNS on the progress of pregnancy and the fetus are not well studied. We tested the hypothesis that VNS in pregnant dams does not induce inflammatory changes in the cardio-respiratory control regions of the pups’ brainstem, potentially impacting the morbidity and mortality of offspring. Pregnant dams were implanted with stimulators providing intermittent low or high frequency electrical stimulation of the sub-diaphragmatic esophageal segment of the vagus nerve for 6–7 days until delivery. After birth, we collected pup brainstems that included cardio-respiratory control regions and counted the cells labeled for pro-inflammatory cytokines (interleukin (IL)-1β, IL-6, tumor necrosis factor-α) and high mobility group box 1. Neither pup viability nor number of cells labeled for pro-inflammatory cytokines in nucleus tractus solitarii or hypoglossal motor nucleus was impaired by VNS. We provide evidence suggesting that chronic VNS of pregnant mothers does not impede the progress or outcome of pregnancy. VNS does not cause preterm birth, affect well-being of progeny, or impact central inflammatory processes that are critical for normal cardiovascular and respiratory function in newborns.