A novel and selective sorbent for micro-solid phase extraction was synthesized by chemical functionalization of graphene oxide with glycine. The structure of this nanomaterial, referred to as GO-Gly, was confirmed by Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, and scanning electron microscopy. GO-Gly was used for preconcentration of chromium, zinc, and copper ions from water samples prior to their determination by energy dispersive X-ray fluorescence spectrometry (EDXRF). The proposed procedure is based on dispersion of micro amounts of GO-Gly in aqueous samples. After adsorption of metal ions on its surface, samples were filtered under vacuum and then membrane filters were directly submitted to energy dispersive X-ray fluorescence spectrometric measurements. In order to obtain optimal preconcentration conditions, some parameters affecting sorption process, such as pH, amount of GO-Gly, sorption times, and sample volume, were examined. Under optimal conditions the calibration curves were linear in a 1–150 ng mL−1 range with recoveries higher than 97%. The obtained detection limits for Cr(III), Zn(II), and Cu(II) determinations are 0.15, 0.07, and 0.08 ng mL−1, respectively. A relative standard deviation of the proposed procedure (at a 10 ng mL−1 level for n = 10) is lower than 2.3%. The proposed method was successfully applied for determination of Cr(III), Zn(II), and Cu(II) ions in water samples.
Molybdenum disulfide (MoS2) was supported on graphene oxide (GO) by hydrothermal method. The resulting nanocomposite (MoS2-rGO) was characterized by X-ray photoelectron spectroscopy, scanning electron microscopy, and transmission electron microscopy. The experiments show that at pH 2, MoS2-rGO has a great affinity for adsorption of hexavalent chromium ions while Cr(III) ions remain in aqueous sample. In the adsorption process, the dominant role plays chemisorption. The determined adsorption capacity is 583.5 mg g−1. Parameters affecting the extraction process, namely sample pH, sample volume, contact time, and matrix ions, were investigated by sequential batch tests. Under optimal conditions (pH 2, sample volume 50 mL, sonication time 10 min, adsorbent mass 1 mg), the calibration curve covers the 1–200 ng mL−1 range with a correlation coefficient (R2) of 0.998. The recovery of the method is 97 ± 3%. Other data of merit include a relative standard deviation of < 3.5%, enrichment factor of 3350, and detection limit of 0.050 ng mL−1. The accuracy of the method was confirmed by analysis of the reference materials QC1453 (chromium VI in drinking water) and QC3015 (chromium VI in seawater). The method was successfully applied to chromium speciation in water samples, including high salinity ones. The concentration of Cr(III) was calculated as the difference between the total concentration of chromium (after oxidation of Cr(III) to Cr(VI) with potassium permanganate) and the initial Cr(VI) content.Graphical abstract
1 September 2018 in Spectrochimica Acta Part B: Atomic Spectroscopy