Liposomes are widely used as a cellular membrane model and may be obtained spontaneously when lipids with cylindrical structure are exposed to an aqueous environment. Giant unilamellar vesicles (GUVs) have diameters greater than 1 μ m and allow obtaining mechanical information spatially resolved at the level of single vesicle. Such structures, have been explored as the main types of models for the study of membrane heterogeneity. The production of GUVs is obtained through the exposure of lipid films to an aqueous solution in the presence of electric fields and stable temperature. This process is called electroformation. This study proposes a novel system to provide a complete automated electroformation process using special chambers. A prototype based on a embedded electronic system was developed to generate and control the desired field frequency and amplitude. Thermoelectric pellets with adequate heat dissipation associated with a thermistor clamped into the electroformation chambers were used to control the temperature. As results, images of confocal fluorescence microscope show that the automated process obtained through the proposed prototype using a standard electroformation protocol produced GUVs with a mean diameter of (5.1 ± 0.6) μ m. Furthermore, the Peltier circuit was adequate to maintain the chamber at a controlled temperature during prolonged experiments and the use of micro-controllers made the system compact, in addition to ensuring a more stable temperature and AC field regime with immediate feedback from the sensors.
This article presents an unsupervised method for segmenting brain computed tomography scans. The proposed methodology involves image feature extraction and application of similarity and continuity constraints to generate segmentation maps of the anatomical head structures. Specifically designed for real-world datasets, this approach applies a spatial continuity scoring function tailored to the desired number of structures. The primary objective is to assist medical experts in diagnosis by identifying regions with specific abnormalities. Results indicate a simplified and accessible solution, reducing computational effort, training time, and financial costs. Moreover, the method presents potential for expediting the interpretation of abnormal scans, thereby impacting clinical practice. This proposed approach might serve as a practical tool for segmenting brain computed tomography scans, and make a significant contribution to the analysis of medical images in both research and clinical settings.