Akara Supratak

Dr. Akara Supratak

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2017 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
ASAkara Supratak
Akara Supratak
HDHao Dong
Hao Dong
CWChao Wu
Chao Wu
YGYike Guo
Yike Guo
This paper proposes a deep learning model, named DeepSleepNet, for automatic sleep stage scoring based on raw single-channelEEG. Most of the existing methods rely on hand-engineered features, which require prior knowledge of sleep analysis. Only a few of them encode the temporal information, such as transition rules, which is important for identifying the next sleep stages, into the extracted features. In the proposed model, we utilize convolutional neural networks to extract time-invariant features, and bidirectional-longshort-term memory to learn transition rules among sleep stages automatically from EEG epochs. We implement a two-step training algorithm to train our model efficiently. We evaluated our model using different single-channel EEGs (F4-EOG (left), Fpz-Cz, and Pz-Oz) from two public sleep data sets, that have different properties (e.g., sampling rate) and scoring standards (AASM and R&K). The results showed that our model achieved similar overall accuracy and macro F1-score (MASS: 86.2%-81.7, Sleep-EDF: 82.0%-76.9) compared with the state-of-the-art methods (MASS: 85.9%-80.5, Sleep-EDF: 78.9%-73.7) on both data sets. This demonstrated that, without changing the model architecture and the training algorithm, our model could automatically learn features for sleep stage scoring from different raw single-channel EEGs from different data sets without utilizing any hand-engineered features.

28 July 2017 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
HDHao Dong
Hao Dong
ASAkara Supratak
Akara Supratak
WPWei Pan
Wei Pan
CWChao Wu
Chao Wu
PMPaul M. Matthews
Paul M. Matthews
YGYike Guo
Yike Guo
This paper proposes a practical approach to addressing limitations posed by using of single-channel electroencephalography (EEG) for sleep stage classification. EEG-based characterizations of sleep stage progression contribute the diagnosis and monitoring of the many pathologies of sleep. Several prior reports explored ways of automating the analysis of sleep EEG and of reducing the complexity of the data needed for reliable discrimination of sleep stages at lower cost in the home. However, these reports have involved recordings from electrodes placed on the cranial vertex or occiput, which are both uncomfortable and difficult to position. Previous studies of sleep stage scoring that used only frontal electrodes with a hierarchical decision tree motivated this paper, in which we have taken advantage of rectifier neural network for detecting hierarchical features and long short-term memory (LSTM) network for sequential data learning to optimize classification performance with single-channel recordings. After exploring alternative electrode placements, we found a comfortable configuration of a single-channel EEG on the forehead and have shown that it can be integrated with additional electrodes for simultaneous recording of the electrooculogram (EOG). Evaluation of data from 62 people (with 494 hours sleep) demonstrated better performance of our analytical algorithm than is available from existing approaches with vertex or occipital electrode placements. Use of this recording configuration with neural network deconvolution promises to make clinically indicated home sleep studies practical.

12 March 2018 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
ZWZhen Wei
Zhen Wei
CWChao Wu
Chao Wu
XWXiaoyi Wang
Xiaoyi Wang
ASAkara Supratak
Akara Supratak
PWPan Wang
Pan Wang
YGYike Guo
Yike Guo
The advertising industry depends on an effective assessment of the impact of advertising as a key performance metric for their products. However, current assessment methods have relied on either indirect inference from observing changes in consumer behavior after the launch of an advertising campaign, which has long cycle times and requires an ad campaign to have already have been launched (often meaning costs having been sunk). Or through surveys or focus groups, which have a potential for experimental biases, peer pressure, and other psychological and sociological phenomena that can reduce the effectiveness of the study. In this paper, we investigate a new approach to assess the impact of advertisement by utilizing low-cost EEG headbands to record and assess the measurable impact of advertising on the brain. Our evaluation shows the desired performance of our method based on user experiment with 30 recruited subjects after watching 220 different advertisements. We believe the proposed SVM method can be further developed to a general and scalable methodology that can enable advertising agencies to assess impact rapidly, quantitatively, and without bias.

19 October 2017
Verified
Conference Paper
Open access
PDF file
HDHao Dong
Hao Dong
ASAkara Supratak
Akara Supratak
LMLuo Mai
Luo Mai
FLFangde Liu
Fangde Liu
AOAxel Oehmichen
Axel Oehmichen
YGYike Guo
Yike Guo
Deep learning has enabled major advances in the fields of computer vision, natural language processing, and multimedia among many others. Developing a deep learning system is arduous and complex, as it involves constructing neural network architectures, managing training/trained models, tuning optimization process, preprocessing and organizing data, etc. TensorLayer is a versatile Python library that aims at helping researchers and engineers efficiently develop deep learning systems. It offers rich abstractions for neural networks, model and data management, and parallel workflow mechanism. While boosting efficiency, TensorLayer maintains both performance and scalability. TensorLayer was released in September 2016 on GitHub, and has helped people from academia and industry develop real-world applications of deep learning.Comment: ACM Multimedia 201

1 August 2014 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
ASAkara Supratak
Akara Supratak
LLLing Li
Ling Li
YGYike Guo
Yike Guo
Scalp electroencephalogram (EEG), a recording of the brain's electrical activity, has been used to diagnose and detect epileptic seizures for a long time. However, most researchers have implemented seizure detectors by manually hand-engineering features from observed EEG data, and used them in seizure detection, which might not scale well to new patterns of seizures. In this paper, we investigate the possibility of utilising unsupervised feature learning, the recent development of deep learning, to automatically learn features from raw, unlabelled EEG data that are representative enough to be used in seizure detection. We develop patient-specific seizure detectors by using stacked autoencoders and logistic classifiers. A two-step training consisting of the greedy layer-wise and the global fine-tuning was used to train our detectors. The evaluation was performed by using labelled dataset from the CHB-MIT database, and the results showed that all of the test seizures were detected with a mean latency of 3.36 seconds, and a low false detection rate.

13 July 2018 in Frontiers in Neurology
Verified
Journal Article
Open access
PDF file
ASAkara Supratak
Akara Supratak
GDGourab Datta
Gourab Datta
AGArie R. Gafson
Arie R. Gafson
RNRichard Nicholas
Richard Nicholas
YGYike Guo
Yike Guo
PMPaul M. Matthews
Paul M. Matthews
Background: The timed 25-foot walk (T25FW) is widely used as a clinic performance measure, but has yet to be directly validated against gait speed in the home environment. Objectives: To develop an accurate method for remote assessment of walking speed and to test how predictive the clinic T25FW is for real-life walking. Methods: An AX3-Axivity tri-axial accelerometer was positioned on 32 MS patients (Expanded Disability Status Scale [EDSS] 0–6) in the clinic, who subsequently wore it at home for up to 7 days. Gait speed was calculated from these data using both a model developed with healthy volunteers and individually personalized models generated from a machine learning algorithm. Results: The healthy volunteer model predicted gait speed poorly for more disabled people with MS. However, the accuracy of individually personalized models was high regardless of disability (R-value = 0.98, p-value = 1.85 × 10−22). With the latter, we confirmed that the clinic T25FW is strongly predictive of the maximum sustained gait speed in the home environment (R-value = 0.89, p-value = 4.34 × 10−8). Conclusion: Remote gait monitoring with individually personalized models is accurate for patients with MS. Using these models, we have directly validated the clinical meaningfulness (i.e., predictiveness) of the clinic T25FW for the first time.