Involvement of important engineering applications in the interaction of free-moving objects with dispersed multi-phase flows are numerous in recent years. However, due to the challenge and complexity, few studies have been reported and modeling approaches remain very limited. This paper reviews the use of discrete particle models (DPMs) for the study of the fluid flow phenomena and elaborates several different types of multiple phases. The efficiency of particle retention and computational time were considered in determining the most appropriate multiphase model. Therefore, the dynamic modeling of multi-scale systems requires a method to solve the problem of structural fluid interaction (FSI) in the particle fluid flow.
1 December 2014 in Journal of Water Process Engineering
This project is to design and develop 3D Independent Floating Water Treatment Device using 3D CAD software. The device is designed to treat water for better water qualities and water flows of the lakes. A prototype was manufactured to study the water treatment efficiency of the device. Computational Fluid Dynamic (CFD) analysis was used to capture the efficiency of the Independent Floating Water Treatment Device by simulates and model the water flows, pressure and velocity. According to the results, the maximum velocity magnitude was around 1m3/s. The velocity contour showed the device has high velocity at the pipe outlet. The velocity became lower and lower as the distance is further from the pipe outlet. The result from the velocity measurement was 1.05m/s. The pressure magnitude was in between 1426 Pa to 1429 Pa. The laboratory results based on water parameters proved that the water movement and direction of water flow of the Independent Floating Water Treatment Device enable the efficient pollutant removal. The vector plot, velocity contour, water flow path lines, water flow streamline and pressure contour was successful modeled.
This paper presents a case study of dam where computational fluid dynamic (CFD) modelling is applied to simulate the three-dimensional (3D) flow hydraulics using computational aided program using ANSYS in order to analyse the existing fluid dynamic from reservoir to spillway of the dam due to long exposure to high pressure of water and high velocity of discharge. The purpose of this study is to ensure efficiency, reliability and safety of the dam generally and specifically on the spillway. Based on the findings, a model that have a worst condition based on both analysis is a model that have bigger area of the opening gate. This is because of the huge amount of the water release from the upstream to the downstream and produce a high value of water velocity and high impact from the water that fall from upstream towards the dam spillway. In order to avoid any sudden huge amount of the water release, the water level of the reservoir need to be check frequently. The water release from the dam need to be control to avoid any disaster to the environment and the dam structure.
Rapid growth in car ownership in Malaysia plays a major role to traffic congestion. Hence, public transportation is crucial to cater the residents in high-density area especially in Klang Valley. Signage information in public transport station is one of an important passenger information system. Poor placement of sign information will decrease the efficiency of passenger flow and caused congestion in the station. Passenger information system is very useful for trip planning and decision making. Therefore, it is interesting to study the performance of passenger information system in focusing the movement behavior of pedestrian at non-peak period. Thus, the study on pedestrian movement during non-peak period on weekdays and weekends in mass transit stations and bus transit stations in Klang Valley was carried out by using video observation. The observation of the pedestrian movement was made in Mass Transit Station 1 in the middle of Kuala Lumpur and Mass Transit Station 2 in southern of Kuala Lumpur. The other site was focused at Bus Transit Station 1 in Putrajaya and Bus Transit Station 2 in Kajang. Findings shown that Mass Transit Station 1 having the best facility in terms of passenger information which the level of service obtained is LOS A, while the lowest level of service which is LOS E was obtained in Bus Transit Station 2.