A S M Muhtasim Fuad Sohan

A S M Muhtasim Fuad Sohan


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2022 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Binfeng YinBinfeng Yin
Binfeng Yin
CQChangcheng Qian
Changcheng Qian
XWXinhua Wan
Xinhua Wan
A S M Muhtasim Fuad SohanA S M Muhtasim Fuad Sohan
A S M Muhtasim Fuad Sohan
Xiaodong LinXiaodong Lin
Xiaodong Lin

28 July 2023 in Foods
Verified
Journal Article
Open access
PDF file
ZJZhuoao Jiang
Zhuoao Jiang
YZYu Zhuang
Yu Zhuang
SGShentian Guo
Shentian Guo
A S M Muhtasim Fuad SohanA S M Muhtasim Fuad Sohan
A S M Muhtasim Fuad Sohan
Binfeng YinBinfeng Yin
Binfeng Yin
Food safety is a significant issue that affects people worldwide and is tied to their lives and health. The issue of pesticide residues in food is just one of many issues related to food safety, which leave residues in crops and are transferred through the food chain to human consumption. Foods contaminated with pesticide residues pose a serious risk to human health, including carcinogenicity, neurotoxicity, and endocrine disruption. Although traditional methods, including gas chromatography, high-performance liquid chromatography, chromatography, and mass spectrometry, can be used to achieve a quantitative analysis of pesticide residues, the disadvantages of these techniques, such as being time-consuming and costly and requiring specialist staff, limit their application. Therefore, there is a need to develop rapid, effective, and sensitive equipment for the quantitative analysis of pesticide residues in food. Microfluidics is rapidly emerging in a number of fields due to its outstanding strengths. This paper summarizes the application of microfluidic techniques to pyrethroid, carbamate, organochlorine, and organophosphate pesticides, as well as to commercial products. Meanwhile, the study also outlines the development of microfluidics in combination with 3D printing technology and nanomaterials for detecting pesticide residues in food.

25 April 2024 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Binfeng YinBinfeng Yin
Binfeng Yin
HZHaoyu Zhu
Haoyu Zhu
SZShiyu Zeng
Shiyu Zeng
A S M Muhtasim Fuad SohanA S M Muhtasim Fuad Sohan
A S M Muhtasim Fuad Sohan
XWXinhua Wan
Xinhua Wan
Xiaodong LinXiaodong Lin
Xiaodong Lin

4 October 2021 in Frontiers in Chemistry
Verified
Journal Article
Open access
Binfeng YinBinfeng Yin
Binfeng Yin
XWXinhua Wan
Xinhua Wan
CQChangcheng Qian
Changcheng Qian
A S M Muhtasim Fuad SohanA S M Muhtasim Fuad Sohan
A S M Muhtasim Fuad Sohan
SWSongbai Wang
Songbai Wang
Teng ZhouTeng Zhou
Teng Zhou
Existing methods for detecting cardiac markers are difficult to be applied in point-of-care testing (POCT) due to complex operation, long time consumption, and low sensitivity. Here, we report a snail-shaped microfluidic chip (SMC) for the multiplex detection of cTnI, CK-MB, and Myo with high sensitivity and a short detection time. The SMC consists of a sandwich structure: a channel layer with a mixer and reaction zone, a reaction layer coated with capture antibodies, and a base layer. The opening or closing of the microchannels is realized by controlling the downward movement of the press-type mechanical valve. The chemiluminescence method was used as a signal readout, and the experimental conditions were optimized. SMC could detect cTnI, CK-MB, and Myo at concentrations as low as 1.02, 1.37, and 4.15. The SMC will be a promising platform for a simultaneous determination of multianalytes and shows a potential application in POCT.

2 November 2021 in ACS Omega
Verified
Journal Article
Open access
Binfeng YinBinfeng Yin
Binfeng Yin
WYWenkai Yue
Wenkai Yue
A S M Muhtasim Fuad SohanA S M Muhtasim Fuad Sohan
A S M Muhtasim Fuad Sohan
Teng ZhouTeng Zhou
Teng Zhou
CQChangcheng Qian
Changcheng Qian
XWXinhua Wan
Xinhua Wan
Micromixers with the microchannel structure can enable rapid and efficient mixing of multiple types of fluids on a microfluidic chip. Herein, we report the mixing performance of three passive micromixers based on the different mathematical spiral structures. We study the fluid flow characteristics of Archimedes spiral, Fermat spiral, and hyperbolic spiral structures with various channel widths and Reynolds number (Re) ranging from 0 to 10 via numerical simulation and visualization experiments. In addition, we analyze the mechanism of streamlines and Dean vortices at different cross sections during fluid flows. As the fluid flows in the Fermat spiral channel, the centrifugal force induces the Dean vortex to form a chaotic advection, enhancing the fluid mixing performance. By integrating the Fermat spiral channel into a microfluidic chip, we successfully detect acute myocardial infarction (AMI) marker with the double-antibody sandwich method and reduce the detection time to 10 min. This method has a low reagent consumption and a high reaction efficiency and demonstrates great potential in point-of-care testing (POCT).

1 August 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
Binfeng YinBinfeng Yin
Binfeng Yin
XWXinhua Wan
Xinhua Wan
A S M Muhtasim Fuad SohanA S M Muhtasim Fuad Sohan
A S M Muhtasim Fuad Sohan
Xiaodong LinXiaodong Lin
Xiaodong Lin
A microfluidic chip is a tiny reactor that can confine and flow a specific amount of fluid into channels of tens to thousands of microns as needed and can precisely control fluid flow, pressure, temperature, etc. Point-of-care testing (POCT) requires small equipment, has short testing cycles, and controls the process, allowing single or multiple laboratory facilities to simultaneously analyze biological samples and diagnose infectious diseases. In general, rapid detection and stage assessment of viral epidemics are essential to overcome pandemic situations and diagnose promptly. Therefore, combining microfluidic devices with POCT improves detection efficiency and convenience for viral disease SARS-CoV-2. At the same time, the POCT of microfluidic chips increases user accessibility, improves accuracy and sensitivity, shortens detection time, etc., which are beneficial in detecting SARS-CoV-2. This review shares recent advances in POCT-based testing for COVID-19 and how it is better suited to help diagnose in response to the ongoing pandemic.