David A. Rotsch

David A. Rotsch

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
DRDavid A. Rotsch
David A. Rotsch
MBM. Alex Brown
M. Alex Brown
JNJerry A. Nolen
Jerry A. Nolen
TBThomas Brossard
Thomas Brossard
WHWalter F. Henning
Walter F. Henning
JGJohn Greene
John Greene

25 January 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
MMMichael Merrick
Michael Merrick
DRDavid A. Rotsch
David A. Rotsch
ATAshok Tiwari
Ashok Tiwari
JNJerry Nolen
Jerry Nolen
TBThomas Brossard
Thomas Brossard
SGStephen A Graves
Stephen A Graves
In recent years the use of beta-emitting radiopharmaceuticals for cancer therapy has expanded rapidly following development of therapeutics for neuroendocrine tumors, prostate cancer, and other oncologic malignancies. One emerging beta-emitting radioisotope of interest for therapy is 67 Cu (t 1/2 : 2.6 d) due to its chemical equivalency with the widely-established positron-emitting isotope 64 Cu (t 1/2 : 12.7 h). In this work we evaluate both the imaging and dosimetric characteristics of 67 Cu, as well as producing the first report of SPECT/CT imaging using 67 Cu. To this end, 67 Cu was produced by photon-induced reactions on isotopically-enriched 68 Zn at the Low-Energy Accelerator Facility (LEAF) of Argonne National Laboratory, followed by bulk separation of metallic 68 Zn by sublimation and radiochemical purification by column chromatography. Gamma spectrometry was performed by efficiency-calibrated high-purity germanium (HPGe) analysis to verify absolute activity calibration and establish radionuclidic purity. Absolute activity measurements corroborated manufacturer-recommended dose-calibrator settings and no radionuclidic impurities were observed. Using the Clinical Trials Network anthropomorphic chest phantom, SPECT/CT images were acquired. Medium energy (ME) SPECT collimation was found to provide the best image quality from the primary 185 keV gamma emission of 67 Cu. Reconstructed images of 67 Cu were similar in quality to images acquired using 177 Lu. Recovery coefficients were calculated and compared against quantitative images of 99m Tc, 177 Lu, and 64 Cu within the same anthropomorphic chest phantom. Production and clinical imaging of 67 Cu appears feasible, and future studies investigating the therapeutic efficacy of 67 Cu-based radiopharmaceuticals are warranted.

13 August 2023 in Molecules
Verified
Journal Article
Open access
PDF file
JMJason Patrick Meier
Jason Patrick Meier
HZHannah J. Zhang
Hannah J. Zhang
RFRichard Freifelder Freifelder
Richard Freifelder Freifelder
MBMohammed Parvez Ismail Bhuiyan
Mohammed Parvez Ismail Bhuiyan
PSPhillip Selman
Phillip Selman
CCChin-Tu Chen
Chin-Tu Chen
In the field of nuclear medicine, the β+ -emitting 43Sc and β− -emitting 47Sc are promising candidates in cancer diagnosis and targeted radionuclide therapy (TRT) due to their favorable decay schema and shared pharmacokinetics as a true theranostic pair. Additionally, scandium is a group-3 transition metal (like 177Lu) and exhibits affinity for DOTA-based chelators, which have been studied in depth, making the barrier to implementation lower for 43/47Sc than for other proposed true theranostics. Before 43/47Sc can see widespread pre-clinical evaluation, however, an accessible production methodology must be established and each isotope’s radiolabeling and animal imaging capabilities studied with a widely utilized tracer. As such, a simple means of converting an 18 MeV biomedical cyclotron to support solid targets and produce 43Sc via the 42Ca(d,n)43Sc reaction has been devised, exhibiting reasonable yields. The NatTi(γ,p)47Sc reaction is also investigated along with the successful implementation of chemical separation and purification methods for 43/47Sc. The conjugation of 43/47Sc with PSMA-617 at specific activities of up to 8.94 MBq/nmol and the subsequent imaging of LNCaP-ENZaR tumor xenografts in mouse models with both 43/47Sc-PSMA-617 are also presented.

3 August 2023 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
PKPavithra H.A. Kankanamalage
Pavithra H.A. Kankanamalage
TBThomas Brossard
Thomas Brossard
JSJeongseog Song
Jeongseog Song
JNJerry Nolen
Jerry Nolen
DRDavid A. Rotsch
David A. Rotsch

1 August 2021 in Journal of Physics Communications
Verified
Journal Article
Open access
MMMichael Merrick
Michael Merrick
DRDavid A. Rotsch
David A. Rotsch
ATAshok Tiwari
Ashok Tiwari
JNJerry Nolen
Jerry Nolen
TBThomas Brossard
Thomas Brossard
SGStephen A Graves
Stephen A Graves
The half-life of 67Cu was determined through serial gamma-ray spectrometry measurements of the dominant gamma emission (E γ : 184.6 keV; branching ratio: 48.7%) produced following β- decay. Data were collected consecutively for 1000 s per measurement, with a total of 3063 measurements over the duration of 36 days. The incidence rate for the 184.6 keV gamma-ray was determined from the spectral peak area and duration of each measurement. This rate was then corrected to account for detector dead-time, radioactive decay during each acquisition and drift in the computer clock in comparison to NIST nuclear clock. Least-squares regression analysis was performed to determine the half-life of 67Cu. The result was 61.761 ± 0.004 h, which is the highest precision measurement to date, and marks a 24-fold precision improvement over the current Nuclear Data Sheets value.

9 February 2024 in Molecules
Verified
Journal Article
Open access
PDF file
BBBrittany Broder
Brittany Broder
MBMohammed Parvez Ismail Bhuiyan
Mohammed Parvez Ismail Bhuiyan
RFRichard Freifelder Freifelder
Richard Freifelder Freifelder
DRDavid A. Rotsch
David A. Rotsch
SCSatish K. Chitneni
Satish K. Chitneni
CCChin-Tu Chen
Chin-Tu Chen
Bis(acetylacetonato)oxidovanadium(IV) [(VO(acac)2], generally known as vanadyl acetylacetonate, has been shown to be preferentially sequestered in malignant tissue. Vanadium-48 (48V) generated with a compact medical cyclotron has been used to label VO(acac)2 as a potential radiotracer in positron emission tomography (PET) imaging for the detection of cancer, but requires lengthy synthesis. Current literature protocols for the characterization of VO(acac)2 require macroscale quantities of reactants and solvents to identify products by color and to enable crystallization that are not readily adaptable to the needs of radiotracer synthesis. We present an improved method to produce vanadium-48-labeled VO(acac)2, [48V]VO(acac)2, and characterize it using high-performance liquid chromatography (HPLC) with radiation detection in combination with UV detection. The approach is suitable for radiotracer-level quantities of material. These methods are readily applicable for production of [48V]VO(acac)2. Preliminary results of preclinical, small-animal PET studies are presented.