With the rapid urbanization in China, directly buried municipal pipelines have been gradually replaced by urban utility tunnels due to a serious shortage of urban underground spaces and weak disaster prevention of traditional municipal pipelines. The urban utility tunnels normally contain electricity pipelines, natural gas pipelines, heat pipelines, sewer pipelines, etc. If a natural gas pipeline leaks, a fire and explosion might occur and lead to serious consequences. In this study, the characteristics of gas explosion in a natural gas compartment of urban utility tunnel are investigated based on FLACS (Flame Acceleration Simulator) simulations. The results revealed that the flame profile undergoes two unstable flame stages. When the ignition position is set at the middle area (100.25, 1.2, 1.4 m) of the 200 m-long natural gas compartment, the maximum overpressure of the gas explosion in the 200 m-long natural gas compartment is 25.17 bar, which is the largest maximum overpressure under all gas explosion simulation setups. It is also found that the length of the natural gas compartment and different ignition positions have slight effects on the maximum overpressure. This study could provide technical support for structural strength design and division of the fireproofing area of the natural gas compartment in the utility tunnel, which is of great significance to improve urban safety during sustainable development.
30 August 2024 in Reliability Engineering & System Safety
In crude oil storage tank fires, large amounts of firefighting water are used, which may trigger boilover. Variations in oil level affect ullage height, while firefighting water injection alters the water layer thickness, with both processes influencing boilover behavior. This study conducts boilover experiments with 3 types of crude oil to investigate the effects of ullage height and water layer thickness. The results show that the water-cooling effect delays boilover onset time, suppresses intensity, and reduces the mass burning rate, with Jidong crude showing the highest reduction (19.2%). However, the water-cooling effect has a limit, and its influence weakens when the water layer thickness exceeds 6 cm. Ullage height affects flame behavior. A moderate increase enhances combustion and shortens boilover onset time, while further increases cause self-extinction. The oil–water interface temperature varies nonlinearly between approximately 100 and 120 °C with changing ullage height. The variation trends of hot wave propagation rate with water layer thickness and ullage height are consistent with those of the burning rate, and correlation equations between them are established. Additionally, the study shows that light crude oil exhibits a later boilover onset with a longer duration and experiences 2~3 distinct boilover events, whereas high-viscosity Jidong crude oil undergoes a single short and intense boilover.
The operational risks of equipment in coalbed methane (CBM) gathering stations exhibit dynamic characteristics. To address this, a dynamic risk assessment method based on Dynamic Bayesian Networks (DBNs) is proposed for CBM station equipment. Additionally, a comprehensive safety management evaluation model is established for gathering station equipment. This approach enables accurate risk assessment and effective implementation of safety management in CBM gathering stations. This method primarily consists of three core components: risk factor identification, dynamic risk analysis, and comprehensive safety management evaluation. First, the Bow-tie model is applied to comprehensively identify risk factors associated with station equipment. Next, a DBN is constructed based on the identified risks, and Markov theory is employed to determine the state transition matrix. Finally, a Comprehensive Safety Management (CSM) evaluation model for gathering station equipment is established. The feasibility of the proposed method is validated through case study applications. The results indicate that during the operation of equipment at CBM gathering stations, priority should be given to strengthening maintenance for medium-hole and enhancing prevention and emergency measures for jet fires. Temperature-controlled spiral-wound heat exchangers, skid-mounted circulating pumps, and pipelines have been identified as critical factors affecting accident occurrence at CBM gathering stations. Enhanced daily inspection and maintenance of this equipment should be implemented. Furthermore, compared to other safety evaluation indicators, the Emergency Preparedness and Response indicator has the most significant impact on the operational safety of CBM gathering station equipment. It requires high-priority attention, thorough implementation of relevant measures, and continuous improvement through targeted actions.
1 June 2025 in Combustion, Explosion, and Shock Waves
Based on the large-eddy-simulation (LES) turbulence model, the shock wave propagation process in the roadway with branch structure was studied, focusing on the changes of overpressure under different explosion intensities and a different number of branches. Four conditions of gas accumulation length of 5, 10, 15, and 20 m are used in four models to reveal the influence of the branch structure. The results show that the shock attenuation coefficient of the main roadway no longer changes linearly with the gas accumulation length when there are branch structures in the roadway. When the gas accumulation length is constant, the increase of the number of branches can effectively reduce the rise rate of the impact overpressure value within a certain propagation distance. The overpressure in the branch roadway away from the explosion site is less affected. Due to the influence of multi-branch structure of adjacent roadway, its fluctuation is more chaotic than that of main roadway.