Anaerobic digestion (AD) is commonly used for the stabilization of agro-food wastes and recovery of energy as methane. Since AD removes organic matter but not nutrients (N and P), additional processes to remove them are usually applied to meet the stringent effluent criteria. However, in the past years, there was a shift from the removal to the recovery of nutrients as a result of increasing concerns regarding limited natural resources and the importance given to the sustainable treatment technologies. Recovering N and P from anaerobically pretreated agro-food wastes as easily transportable and marketable products has gained increasing importance to meet both regulatory requirements and increase revenue. For this reason, this review paper gives a critical comparison of the available and emerging technologies for N and P recovery from AD residues.
Corrosion of copper pipes may release high amounts of copper into the water, exceeding the maximum concentration of copper for drinking water standards. Typically, the events with the highest release of copper into drinking water are related to the presence of biofilms. This article reviews this phenomenon, focusing on copper ingestion and its health impacts, the physicochemical mechanisms and the microbial involvement on copper release, the techniques used to describe and understand this phenomenon, and the hydrodynamic effects. A conceptual model is proposed and the mathematical models are reviewed.
1 December 2017 in Science of The Total Environment
A novel biofilm model is described which systemically couples bacteria, extracellular polymeric substances (EPS) and solvent phases in biofilm. This enables the study of contributions of rheology of individual phases to deformation of biofilm in response to fluid flow as well as interactions between different phases. The model, which is based on first and second laws of thermodynamics, is derived using an energetic variational approach and phase-field method. Phase-field coupling is used to model structural changes of a biofilm. A newly developed unconditionally energy-stable numerical splitting scheme is implemented for computing the numerical solution of the model efficiently. Model simulations predict biofilm cohesive failure for the flow velocity between and m s −1 which is consistent with experiments. Simulations predict biofilm deformation resulting in the formation of streamers for EPS exhibiting a viscous-dominated mechanical response and the viscosity of EPS being less than . Higher EPS viscosity provides biofilm with greater resistance to deformation and to removal by the flow. Moreover, simulations show that higher EPS elasticity yields the formation of streamers with complex geometries that are more prone to detachment. These model predictions are shown to be in qualitative agreement with experimental observations.
Aims: This study used culture‐dependent and culture‐independent approaches to characterize bacterial communities in copper plumbing corrosion and to assess biofilm formation and copper resistance of heterotrophic bacteria isolated from copper pipes. Methods and Results: Water and copper pipes were collected from a cold‐water household distribution system affected by ‘blue water’ corrosion and presenting biofilm formation. Corrosion‐promoting ageing experiments were performed with conditioned unused copper pipes filled with unfiltered and filtered sampled water as nonsterile and sterile treatments, respectively. During 8 weeks, stagnant water within the pipes was replaced with aerated fresh water every 2 or 3 days. Total copper and pH were determined in sampled water, and copper pipe coupons were cut for microscopic analyses. Biofilms were extracted from field and laboratory pipes, and total DNA was isolated. Bacterial communities’ composition was analysed by terminal restriction fragment length polymorphism (T‐RFLP) and clonal libraries of 16S rRNA genes. Heterotrophic bacterial isolates were obtained from water and biofilm extracts and characterized in terms of biofilm formation capacity and copper minimum inhibitory concentration. The results indicated that copper concentration in stagnant water from nonsterile treatments was much higher than in sterile treatments and corrosion by‐products structure in coupon surfaces was different. Multivariate analysis of T‐RFLP profiles and clone sequencing showed significant dissimilarity between field and laboratory biofilm communities, and a low richness and the dominant presence of Gamma‐ and Betaproteobacteria in both cases. Several bacterial isolates formed biofilm and tolerated high copper concentrations. Conclusions: The study demonstrates microbially influenced corrosion (MIC) in copper plumbing. Gamma‐ and Betaproteobacteria dominated the corroded copper piping bacterial community, whose ability to form biofilms may be important for bacterial corrosion promotion and survival in MIC events. Significance and Impact of the Study: The characterization of micro‐organisms that influence copper plumbing corrosion has significant implications for distribution system management and copper corrosion control.