María-Gloria Baena-Nieto

Dr. María-Gloria Baena-Nieto


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2010 in Sensors
Verified
Journal Article
Open access
PDF file
ITIsabel Torres
Isabel Torres
MBMaría-Gloria Baena-Nieto
María-Gloria Baena-Nieto
MCManuel Cayon
Manuel Cayon
JOJose Ortego-Rojo
Jose Ortego-Rojo
MDManuel Aguilar Diosdado
Manuel Aguilar Diosdado
Glucose control is the cornerstone of Diabetes Mellitus (DM) treatment. Although self-regulation using capillary glycemia (SRCG) still remains the best procedure in clinical practice, continuous glucose monitoring systems (CGM) offer the possibility of continuous and dynamic assessment of interstitial glucose concentration. CGM systems have the potential to improve glycemic control while decreasing the incidence of hypoglycemia but the efficiency, compared with SRCG, is still debated. CGM systems have the greatest potential value in patients with hypoglycemic unawareness and in controlling daily fluctuations in blood glucose. The implementation of continuous monitoring in the standard clinical setting has not yet been established but a new generation of open and close loop subcutaneous insulin infusion devices are emerging making insulin treatment and glycemic control more reliable.Glucose control is the cornerstone of Diabetes Mellitus (DM) treatment. Although self-regulation using capillary glycemia (SRCG) still remains the best procedure in clinical practice, continuous glucose monitoring systems (CGM) offer the possibility of continuous and dynamic assessment of interstitial glucose concentration. CGM systems have the potential to improve glycemic control while decreasing the incidence of hypoglycemia but the efficiency, compared with SRCG, is still debated. CGM systems have the greatest potential value in patients with hypoglycemic unawareness and in controlling daily fluctuations in blood glucose. The implementation of continuous monitoring in the standard clinical setting has not yet been established but a new generation of open and close loop subcutaneous insulin infusion devices are emerging making insulin treatment and glycemic control more reliable.

9 December 2019 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MMMaría Molina-Vega
María Molina-Vega
CRCarlos Antonio Rodríguez-Pérez
Carlos Antonio Rodríguez-Pérez
AÁAna Isabel Álvarez-Mancha
Ana Isabel Álvarez-Mancha
MBMaría-Gloria Baena-Nieto
María-Gloria Baena-Nieto
MFMaría Riestra Fernández
María Riestra Fernández
JFJose C. Fernandez-Garcia
Jose C. Fernandez-Garcia
Introduction: Thyroid nodules are a common finding. A high-resolution thyroid nodule clinic (HR-TNC) condenses all tests required for the evaluation of thyroid nodules into a single appointment. We aimed to evaluate the clinical outcomes at HR-TNCs. Design and Methods: A retrospective cross-sectional multicenter study including data from four HR-TNCs in Spain. We evaluated fine-needle aspiration (FNA) indications and the association between clinical and ultrasound characteristics with cytological and histopathological outcomes. Results: A total of 2809 thyroid nodules were included; FNA was performed in 82.1%. Thyroid nodules that underwent FNA were more likely larger, isoechoic, with microcalcifications, and in younger subjects. The rate of nondiagnostic FNA was 4.3%. A solid component, irregular margins or microcalcifications, significantly increased the odds of Bethesda IV-V-VI (vs. Bethesda II). Irregular margins and a solid component were independently associated with increased odds of malignancy. Thyroid nodules <20 mm and ≥20–<40 mm had a 6.5-fold and 3.3-fold increased risk for malignancy respectively in comparison with those ≥40 mm. Conclusion: In this large multicenter study, we found that the presence of a solid component and irregular margins are factors independently related to malignancy in thyroid nodules. Since nodule size ≥40 mm was associated with the lowest odds of malignancy, this cut-off should not be a factor leading to indicate thyroid surgery. HR-TNCs were associated with a low rate of nondiagnostic FNA.

4 December 2025 in Endocrinología, Diabetes y Nutrición (English Ed.)
Verified
Journal Article
Closed access
LALuis Muñoz Arenas
Luis Muñoz Arenas
MCMercedes Senent Capote
Mercedes Senent Capote
JPJavier Olmedo Pérez-Montaut
Javier Olmedo Pérez-Montaut
AMAntonio Ballesteros Martín-Portugués
Antonio Ballesteros Martín-Portugués
ESEsteban Sánchez-Toscano
Esteban Sánchez-Toscano
MBMaría-Gloria Baena-Nieto
María-Gloria Baena-Nieto