Pernille Lund Kasper

Pernille Lund Kasper


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2018 in Sensors
Verified
Journal Article
Open access
PDF file
MHMichael Jørgen Hansen
Michael Jørgen Hansen
PKPernille Lund Kasper
Pernille Lund Kasper
AAAnders Peter Adamsen
Anders Peter Adamsen
AFAnders Feilberg
Anders Feilberg
Analytical measurements of odorants in combination with odor threshold values is an alternative to sensory measurements that can be used to evaluate abatement technologies for pig production facilities. The purpose of the present study was to estimate odor threshold values for key odorants found in pig house air. A new method was applied where an olfactometer was used to dilute the sample air and the concentrations of odorants presented to the panelists at the dilutions steps were measured by proton-transfer-reaction mass spectrometry (PTR-MS). The results demonstrate that the odor threshold values of acetic acid, butanoic acid, and 4-methylphenol are considerably lower than reported previously, whereas the values of hydrogen sulfide, methanethiol and dimethylsulfide were comparable. Consequently, acetic acid, butanoic acid, and 4-methyl-phenol will have a larger influence on odor from pig production facilities than previously assumed. The results highlight the necessity for directly measuring exposure concentrations when determining odor threshold values.

1 March 2018 in Journal of Environmental Quality
Verified
Journal Article
Open access
PDF file
PKPernille Lund Kasper
Pernille Lund Kasper
AOArne Oxbøl
Arne Oxbøl
MHMichael Jørgen Hansen
Michael Jørgen Hansen
AFAnders Feilberg
Anders Feilberg
Alteration of the chemical composition of odor samples during storage in polymer sample bags can significantly impair the accuracy of subsequent odor evaluations. To overcome or minimize this effect, the mechanisms determining compound loss must be more thoroughly understood. The present study examines the storage stability of a selection of key odorants from livestock production in polymer sample bags of Nalophan, Tedlar, and polytetrafluoroethylene (PTFE). The compounds included are acetic acid, butanoic acid, propanoic acid, 3‐methylbutanoic acid, hydrogen sulfide, methanethiol, dimethyl sulfide, trimethylamine, and 4‐methylphenol. The fate of the unrecovered compound fractions is clarified by means of thermal desorption and concentric double bags, allowing estimation of the magnitude of losses due to adsorption and diffusion, respectively. The degree of recovery was found to be PTFE > Tedlar > Nalophan, and smaller ratios of bag surface area to sample volume improved the recovery significantly. Furthermore, PTFE bags were found far superior for maintaining the original sample humidity and for storing 4‐methylphenol. Analysis of sample humidity, partitioning coefficients, and thermal desorption suggested that the loss in PTFE bags was mainly controlled by adsorption, whereas for Nalophan and Tedlar, compound loss is a combined effect of adsorption and diffusion. It is suggested to heat the bags when evacuating the sample for analysis, as this was found to improve the recovery significantly. For a 5‐L PTFE bag, all odorants could be found at concentration levels between 71.6 and 98.8% even after 48 h of storage when heated to 57°C prior to analysis.Core Ideas: Loss mechanisms of livestock odorants in sampling bags were investigated by PTR‐MS Three approved types of sampling bags were studied: Nalophan, Tedlar, and PTFE Double bags and sequential heating are used to assess diffusion and surface sorption The best storage is obtained with PTFE bags combined with gentle heating Loss rates in sampling bags are strongly influenced by compound volatility

11 August 2017 in Sensors
Verified
Journal Article
Open access
PDF file
PKPernille Lund Kasper
Pernille Lund Kasper
DMDietmar Mannebeck
Dietmar Mannebeck
AOArne Oxbøl
Arne Oxbøl
JNJens Vinge Nygaard
Jens Vinge Nygaard
MHMichael Jørgen Hansen
Michael Jørgen Hansen
AFAnders Feilberg
Anders Feilberg
The present study provides an elaborate assessment of the performance of olfactometers in terms of odorant recovery for a selection of odorants emitted from livestock houses. The study includes three different olfactometer dilution systems, which have been in use at accredited odor laboratories. They consist of: (i) a custom-built olfactometer made of glass tubes, (ii) a TO8 olfactometer, and (iii) an Olfacton dilution system based on a mass flow controller. The odorants include hydrogen sulfide, methanethiol, dimethyl sulfide, acetic acid, butanoic acid, propanoic acid, 3-methylbutanoic acid, 4-methylphenol, and trimethylamine. Furthermore, n-butanol, as the reference gas in the European standard for olfactometry, EN13725, was included. All measurements were performed in real time with proton-transfer-reaction mass spectrometry (PTR-MS). The results show that only dimethyl sulfide was almost completely recovered in all cases, while for the remaining compounds, the performance was found to vary significantly (from 0 to 100%) depending on the chemical properties of the compounds, the concentration levels, the pulse duration, and the olfactometer material. To elucidate the latter, the recovery in different locations of the TO8 olfactometer and in tubes of different materials, that is, poly-tetrafluoroethylene (PTFE), perfluoroalkoxy (PFA), stainless steel and SilcoTek-coated steel, were tested. Significant saturation effects were observed when odorants were in contact with stainless steel.

8 January 2019 in Journal of Chemical Technology & Biotechnology
Verified
Journal Article
Closed access
PDF file
PKPernille Lund Kasper
Pernille Lund Kasper
AFAnders Feilberg
Anders Feilberg

26 July 2026 in Biosystems Engineering
Verified
Journal Article
Closed access
PKPernille Lund Kasper
Pernille Lund Kasper
PLPawel Michal Lycus
Pawel Michal Lycus
MHMichael Holm
Michael Holm