SHI X. J.

Mr. SHI X. J.

Naval Aviation University, Yantai, Shandong, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YQYufeng Qin
Yufeng Qin
SJSHI X. J.
SHI X. J.
As a critical component in industrial systems, timely and accurate fault diagnosis of rolling bearings is closely related to reliability and safety. Since the equipment usually operates in normal conditions with few fault samples, unbalanced data distribution problems lead to poor fault diagnosis ability. To address the above problems, a two-channel convolutional neural network (TC-CNN) model is proposed. Firstly, the frequency spectrum of the vibration signal is extracted using the Fast Fourier Transform (FFT), and the frequency spectrum is used as the input to the one-dimensional convolutional neural network (1D-CNN). Secondly, the time-frequency image of the vibration signal is extracted using generalized S-transform (GST), and the time-frequency image is used as the input to the two-dimensional convolutional neural network (2D-CNN). Then, feature extraction in the convolution and pooling layers is performed in the above two CNN channels, respectively. The feature vectors obtained from the two CNN models are stitched together in the fusion layer, and the fault classes are identified using an SVM classifier. Finally, using the rolling bearing experimental dataset of Case Western Reserve University (CWRU), the fault diagnosis effect of the proposed TC-CNN model under various data imbalance conditions is verified. In comparison with other related works, the experimental results demonstrate the better fault diagnosis results and robustness of the method.

21 June 2022 in IEEE Access
Verified
Journal Article
Open access
SJSHI X. J.
SHI X. J.
YQYufeng Qin
Yufeng Qin
LZLi Zhao.
Li Zhao.
The optimal test point placement problem in existing research results is mainly limited to the qualitative study of whether faults can be diagnosed without considering the difficulty of diagnosing faults. We proposed an optimal test point placement approach based on fault diagnosability quantitative evaluation to solve the above problem. First, the fault diagnosability is quantitatively evaluated based on the maximum mean discrepancy (MMD). Then, the problem of optimal test point placement is considered a multi objective optimization problem. The optimal test point set is solved using the multi objective sparrow search algorithm (MOSSA) based on the fault diagnosability quantitative evaluation results, considering limitations on the test point number, reliability, and cost. Finally, the proposed approach is used to optimize the placement of test points in the switching power supply system. The simulation results show that only three test points need to be placed to make the system meet the fault diagnosability requirements. Two test point placement schemes are obtained, which can be selected according to different practical requirements. The experimental results illustrate that the proposed approach can optimize the system test point placement while ensuring good fault diagnosability.

28 April 2022 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
YQYufeng Qin
Yufeng Qin
SJSHI X. J.
SHI X. J.
YLYufeng Long
Yufeng Long
JLJia-Peng Lv
Jia-Peng Lv
This paper deals with the robust fault detection problem in the finite frequency domain for a class of Lipschitz nonlinear systems with uncertain parameters. The design conditions of fault detection observers are proposed. These conditions make the error estimation system stable, and the residual has disturbance attenuation performance for external disturbances and uncertain parameters. In addition, considering that fault occurs in the finite frequency domain, the residual also has fault sensitivity performance. To ease of solution, the observer design conditions are further transformed into linear matrix inequalities. On this basis, a dynamic threshold design method based on analysis is presented. Finally, simulation results demonstrate the superiority of the proposed method.

1 August 2014
Verified
Conference Paper
Closed access
YXYongxing Xie
Yongxing Xie
TLTao Lin
Tao Lin
YLYang Li
Yang Li
SJSHI X. J.
SHI X. J.
Intermittent chaos will take place if the weak signal whose frequency is slightly different from that of the driving force of the Duffing oscillator. An array of oscillators is always used to detect signal of unknown frequency. By changing the common ratio and adding an addition test oscillator, the number of the oscillators is reduced from 79 to 40. A shifting cross zero point chain method is presented to measure the cycle time of the intermittent chaos, and the simulation to show its viability is performed.

29 October 2021 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
YLYufeng Long
Yufeng Long
SJSHI X. J.
SHI X. J.
QCQiangqiang Chen
Qiangqiang Chen
ZXZhicai Xiao
Zhicai Xiao
YQYufeng Qin
Yufeng Qin
JLJia-Peng Lv
Jia-Peng Lv
Early fault diagnosis of bearings is the basis of condition-based maintenance. To overcome the difficulty of early fault diagnosis for the mechanical system, a new conception named quantile multiscale permutation entropy (QMPE) is defined, and a new feature extraction method based on QMPE is proposed. On the basis of the multiscale entropy, the multiscale permutation entropy for the gathered vibration signal of equipment is obtained, and the sample quantile is calculated, which is employed to analyze the weak change of the variation signal. The proposed method is verified with the full lifetime datasets of a certain bearing, which proves that signal features extracted by the QMPE method can not only truly express the bearing detailed condition changing from normal to fault but also duly detect the early fault of the bearing. Comparing with other methods for early fault diagnosis, the proposed method can advance the finding time of the early fault obviously.

22 May 2021
Verified
Conference Paper
Closed access
YQYufeng Qin
Yufeng Qin
SJSHI X. J.
SHI X. J.
YLYufeng Long
Yufeng Long
JLJiapeng Lv
Jiapeng Lv
ZZZhilong Zhang
Zhilong Zhang
LZLi Zhao
Li Zhao
In the present study of fault diagnosability of nonlinear systems, the fault diagnosability of sensor fault is not considered. The paper considered the sensor fault and the fault diagnosability evaluation method for a class of affine nonlinear systems is proposed by using the theory of differential geometry. The diagnosability of faults is regarded as an inherent property of the system and does not change with the change of diagnostic methods. Based on the controllability and observability decomposition theorems, the controllability distribution and observability distribution of faults are defined, and then the detectability and isolability criteria between process faults and sensor faults are given based on the containment relationship between each distribution. The analysis results show that the proposed method is suitable for the system which exists sensor faults.