The development of biomaterials such as synthetic scaffolds for peripheral nerve regeneration requires a precise knowledge of the mechanical properties of the nerve in physiological-like conditions. Mechanical properties (Young's modulus, maximum stress and strain at break) for peripheral nerves are scarce and large discrepancies are observed in between reports. This is due in part to the absence of a robust testing device for nerves. To overcome this limitation, a custom-made tensile device (CMTD) has been built. To evaluate its reproducibility and accuracy, the imposed speed and distance over measured speed and distance was performed, followed by a validation using poly(dimethylsiloxane) (PDMS), a commercial polymer with established mechanical properties. Finally, the mechanical characterization of rodents (mice and rats) sciatic nerves using the CMTD was performed. Mouse and rat sciatic nerves Young's modulus were 4.57 ± 2.04 and 19.2 ± 0.86 MPa respectively. Maximum stress was 1.26 ± 0.56 MPa for mice and 3.81 ± 1.84 MPa for rats. Strain at break was 53 ± 17% for mice and 32 ± 12% for rats. The number of axons per sciatic nerve was found to be twice higher for rats. Statistical analysis of the measured mechanical properties revealed no sex-related trends, for both mice and rats (except for mouse maximum stress with p=0.03). Histological evaluation of rat sciatic nerve corroborated these findings. By developing a robust CMTD to establish the key mechanical properties (Young's modulus, maximum stress and strain at break) values for rodents sciatic nerves, our work represent an essential step toward the development of better synthetic scaffolds for peripheral nerve regeneration.
Peripheral nerve injuries (PNIs) are detrimental to the quality of life of affected individuals. Patients are often left with life-long ailments that affect them physically and psychologically. Autologous nerve transplant is still the gold standard treatment for PNIs despite limited donor site and partial recovery of nerve functions. Nerve guidance conduits are used as a nerve graft substitute and are efficient for the repair of small nerve gaps but require further improvement for repairs exceeding 30 mm. Freeze-casting is an interesting fabrication method for the conception of scaffolds meant for nerve tissue engineering since the microstructure obtained comprises highly aligned micro-channels. The present work focuses on the fabrication and characterization of large scaffolds (35 mm length, 5 mm diameter) made of collagen/chitosan blends by freeze-casting via thermoelectric effect instead of traditional freezing solvents. As a freeze-casting microstructure reference, scaffolds made from pure collagen were used for comparison. Scaffolds were covalently crosslinked for better performance under load and laminins were further added to enhance cell interactions. Microstructural features of lamellar pores display an average aspect ratio of 0.67 ± 0.2 for all compositions. Longitudinally aligned micro-channels are reported as well as enhanced mechanical properties in traction under physiological-like conditions (37 °C, pH = 7.4) resulting from crosslinking treatment. Cell viability assays using a rat Schwann cell line derived from sciatic nerve (S16) indicate that scaffold cytocompatibility is similar between scaffolds made from collagen only and scaffolds made from collagen/chitosan blend with high collagen content. These results confirm that freeze-casting via thermoelectric effect is a reliable manufacturing strategy for the fabrication of biopolymer scaffolds for future peripheral nerve repair applications.