Heyde syndrome is the co-occurrence of aortic stenosis, acquired von Willebrand syndrome, and gastrointestinal bleeding. Aortic valve replacement has been demonstrated to resolve all three associated disorders. A systematic review and meta-analysis were performed to obtain best estimates of the effect of aortic valve replacement on acquired von Willebrand syndrome and gastrointestinal bleeding. A literature search was performed to identify articles on Heyde syndrome and aortic valve replacement up to 25 October 2022. Primary outcomes were the proportion of patients with recovery of acquired von Willebrand syndrome within 24 h (T1), 24–72 h (T2), 3–21 days (T3), and 4 weeks to 2 years (T4) after aortic valve replacement and the proportion of patients with cessation of gastrointestinal bleeding. Pooled proportions and risk ratios were calculated using random-effects models. Thirty-three studies (32 observational studies and one randomized controlled trial) on acquired von Willebrand syndrome (n = 1054), and 11 observational studies on gastrointestinal bleeding (n = 300) were identified. One study reported on both associated disorders (n = 6). The pooled proportion of Heyde patients with acquired von Willebrand syndrome recovery was 86% (95% CI, 79%–91%) at T1, 90% (74%–96%) at T2, 92% (84%–96%) at T3, and 87% (67%–96%) at T4. The pooled proportion of Heyde patients with gastrointestinal bleeding cessation was 73% (62%–81%). Residual aortic valve disease was associated with lower recovery rates of acquired von Willebrand syndrome (RR 0.20; 0.05–0.72; P = 0.014) and gastrointestinal bleeding (RR 0.57; 0.40–0.81; P = 0.002). Aortic valve replacement is associated with rapid recovery of the bleeding diathesis in Heyde syndrome and gastrointestinal bleeding cessation. Residual valve disease compromises clinical benefits. Heyde syndrome is effectively treated by aortic valve replacement.
5 July 2022 in Circulation: Cardiovascular Interventions
Background: Heyde syndrome is the co-occurrence of aortic stenosis and gastrointestinal bleeding secondary to angiodysplasias. Surgical aortic valve replacement effectively reduces bleeding, but the effects of transcatheter aortic valve implantation (TAVI) are largely unknown. This study aimed to describe the reduction of gastrointestinal bleeding in patients with Heyde syndrome after TAVI and to identify the factors associated with rebleeding. Methods: We enrolled patients with Heyde syndrome from a prospective TAVI registry. Gastrointestinal bleeding episodes were assessed by the Bleeding Academic Research Consortium classification, and cumulative incidence functions were used to calculate cessation rates. Factors potentially associated with rebleeding were analyzed using logistic regression. Differences between Heyde and non-Heyde patients were assessed through a case-cohort study. Results: Between December 2008 and June 2020, 1111 patients underwent TAVI. There were 70 patients with Heyde syndrome (6.3%). In the first year following TAVI, gastrointestinal bleeding ceased in 46 of 70 patients (62% [95% CI, 50%–74%]). Bleeding episodes decreased from 3.2 (95% CI, 2.5–4.2) to 1.6 ([95% CI, 1.2–2.2] P =0.001) and hemoglobin levels increased from 10.3 (95% CI, 10.0–10.8) to 11.3 (95% CI, 10.8–11.6) g/dL ( P =0.007). Between 1 and 5 years after TAVI (35 [interquartile range, 21–51] months), 53 of 62 patients (83% [95% CI, 72%–92%]) no longer experienced gastrointestinal bleeding. Paravalvular leakage (≥mild) was associated with rebleeding risk (odds ratio, 3.65 [95% CI, 1.36–9.80]; P =0.010). Periprocedural bleeding was more common in Heyde than in control patients (adjusted odds ratio, 2.55 [95% CI, 1.37–4.73]; P =0.003). Conclusions: Patients with Heyde syndrome are at increased risk for periprocedural bleeding. Post-TAVI, gastrointestinal bleeding disappears in the majority of patients. Paravalvular leakage may curtail these clinical benefits.
20 April 2024 in European Heart Journal - Imaging Methods and Practice
Transcatheter aortic valve replacement (TAVR) is the standard of care in aortic stenosis with results comparable to surgical aortic valve replacement. However, paravalvular regurgitation (PVR) is more common after TAVR. With the alteration of devices and implantation techniques, the incidence of moderate or more PVR has declined. Mild PVR is still common in around 30% of TAVR patients in low-risk trials. Progression of AS causes myocardial hypertrophy and varying degrees of diastolic dysfunction which may cause heart failure even in combination with small volumes of PVR. Any degree of PVR is associated with an increased risk of overall and cardiovascular mortality. Predictors of PVR are annular eccentricity, severe calcification of the aortic valve, bicuspid aortic valves, and type of prosthesis where balloon-expandable devices are associated with less PVR. PVR is diagnosed using echocardiography, aortic angiogram with or without videodensitometry, haemodynamic parameters, or cardiac magnetic resonance. PVR can be treated using post-dilation, interventional treatment using a vascular plug, or implantation of a second device. Successful post-dilation depends on balloon size which should at least be equal to or >95% of the mean annulus diameter. Implantation of a second device to reduce PVR is successful in ∼90% of cases, either through lengthening of the sealing skirt in case of inadequate position or through further expansion of the index device. Implantation of a vascular plug can successfully reduce PVR and reduce mortality.
1 November 2020 in JACC: Cardiovascular Interventions
Background: The Myval balloon-expandable (BE) valve has shown encouraging early clinical data in terms of safety and efficacy. Comparative data with other well-established contemporary valves are nonetheless still scarce. This study aims to compare the performance of the Myval BE valve with the Evolut self-expanding (SE) valve. Methods: In this retrospective single-center study, 223 patients with symptomatic severe aortic stenosis (AS) were included and treated with the Myval BE valve (n = 120) or with the Evolut SE valve (n = 103). Then, 91 pairs were compared after matching. Clinical outcomes were evaluated at 30 days and 1 year. Echocardiographic follow-up was performed at 30 days. Results: Procedural complications were rare in both groups. At the 30-day follow-up, no significant difference in cardiac death (Myval: 1% vs. Evolut: 2%, p = 0.56), stroke (2% vs. 4%, p = 0.41) and myocardial infarction (1% vs. 3%, p = 0.31) was observed. A permanent pacemaker implantation (PPI) was significantly less needed in the Myval group (4% vs. 15%, p = 0.01). At 1 year, cardiac death (2% vs. 4%, p = 0.41) and the stroke rate (7% vs. 5%, p = 0.76) were similar. Moderate–severe paravalvular leakage (PVL) was also comparable in both groups (1% vs. 4%, p = 0.17). Conclusion: Safety and efficacy outcomes were comparable between the two valves, except for a higher PPI rate for the Evolut SE valve. Up to 1-year follow-up, clinical outcomes showed acceptable rates of stroke and cardiac death with both valves. Valve hemodynamics were excellent with a low rate of moderate–severe PVL in both groups.