Chenbin Ma

Dr. Chenbin Ma

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2022 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
CMChenbin Ma
Chenbin Ma
PZPeng Zhang
Peng Zhang
FSFan Song
Fan Song
YSYangyang Sun
Yangyang Sun
GFGuangda Fan
Guangda Fan
GZGuanglei Zhang
Guanglei Zhang
Ambulatory blood pressure (BP) monitoring plays a critical role in the early prevention and diagnosis of cardiovascular diseases. However, cuff-based inflatable devices cannot be used for continuous BP monitoring, while pulse transit time or multi-parameter-based methods require more bioelectrodes to acquire electrocardiogram signals. Thus, estimating the BP waveforms only based on photoplethysmography (PPG) signals for continuous BP monitoring has essential clinical values. Nevertheless, extracting useful features from raw PPG signals for fine-grained BP waveform estimation is challenging due to the physiological variation and noise interference. For single PPG analysis utilizing deep learning methods, the previous works depend mainly on stacked convolution operation, which ignores the underlying complementary time-dependent information. Thus, this work presents a novel Transformer-based method with knowledge distillation (KD-Informer) for BP waveform estimation. Meanwhile, we integrate the prior information of PPG patterns, selected by a novel backward elimination algorithm, into the knowledge transfer branch of the KD-Informer. With these strategies, the model can effectively capture the discriminative features through a lightweight architecture during the learning process. Then, we further adopt an effective transfer learning technique to demonstrate the excellent generalization capability of the proposed model using two independent multicenter datasets. Specifically, we first fine-tuned the KD-Informer with a large and high-quality dataset (Mindray dataset) and then transferred the pre-trained model to the target domain (MIMIC dataset). The experimental test results on the MIMIC dataset showed that the KD-Informer exhibited an estimation error of 0.02 ± 5.93 mmHg for systolic BP (SBP) and 0.01 ± 3.87 mmHg for diastolic BP (DBP), which complied with the association for the advancement of medical instrumentation (AAMI) standard. These results demonstrate that the KD-Informer has high reliability and elegant robustness to measure continuous BP waveforms.

8 August 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
XZXiangyu Zhao
Xiangyu Zhao
PZPeng Zhang
Peng Zhang
FSFan Song
Fan Song
CMChenbin Ma
Chenbin Ma
GFGuangda Fan
Guangda Fan
GZGuanglei Zhang
Guanglei Zhang
The accurate segmentation of multiple types of lesions from adjacent tissues in medical images is significant in clinical practice. Convolutional neural networks (CNNs) based on the coarse-to-fine strategy have been widely used in this field. However, multi-lesion segmentation remains to be challenging due to the uncertainty in size, contrast, and high interclass similarity of tissues. In addition, the commonly adopted cascaded strategy is rather demanding in terms of hardware, which limits the potential of clinical deployment. To address the problems above, we propose a novel Prior Attention Network (PANet) that follows the coarse-to-fine strategy to perform multi-lesion segmentation in medical images. The proposed network achieves the two steps of segmentation in a single network by inserting a lesion-related spatial attention mechanism in the network. Further, we also propose the intermediate supervision strategy for generating lesion-related attention to acquire the regions of interest (ROIs), which accelerates the convergence and obviously improves the segmentation performance. We have investigated the proposed segmentation framework in two applications: 2D segmentation of multiple lung infections in lung CT slices and 3D segmentation of multiple lesions in brain MRIs. Experimental results show that in both 2D and 3D segmentation tasks our proposed network achieves better performance with less computational cost compared with cascaded networks. The proposed network can be regarded as a universal solution to multi-lesion segmentation in both 2D and 3D tasks. The source code is available at https: //github.com/hsiangyuzhao/PANet.

18 July 2024 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
YHYufang He
Yufang He
ZLZeyu Liu
Zeyu Liu
MQMingxin Qi
Mingxin Qi
SDShengwei Ding
Shengwei Ding
PZPeng Zhang
Peng Zhang
GZGuanglei Zhang
Guanglei Zhang
Histopathological examinations heavily rely on hematoxylin and eosin (HE) and immunohistochemistry (IHC) staining. IHC staining can offer more accurate diagnostic details but it brings significant financial and time costs. Furthermore, either re-staining HE-stained slides or using adjacent slides for IHC may compromise the accuracy of pathological diagnosis due to information loss. To address these challenges, we develop PST-Diff, a method for generating virtual IHC images from HE images based on diffusion models, which allows pathologists to simultaneously view multiple staining results from the same tissue slide. To maintain the pathological consistency of the stain transfer, we propose the asymmetric attention mechanism (AAM) and latent transfer (LT) module in PST-Diff. Specifically, the AAM can retain more local pathological information of the source domain images through the design of asymmetric attention mechanisms, while ensuring the model’s flexibility in generating virtual stained images that highly confirm to the target domain. Subsequently, the LT module transfers the implicit representations across different domains, effectively alleviating the bias introduced by direct connection and further enhancing the pathological consistency of PST-Diff. Furthermore, to maintain the structural consistency of the stain transfer, the conditional frequency guidance (CFG) module is proposed to precisely control image generation and preserve structural details according to the frequency recovery process. To conclude, the pathological and structural consistency constraints provide PST-Diff with effectiveness and superior generalization in generating stable and functionally pathological IHC images with the best evaluation score. In general, PST-Diff offers prospective application in clinical virtual staining and pathological image analysis.

4 January 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
TZTianyi Zhang
Tianyi Zhang
YFYunlu Feng
Yunlu Feng
YZYu Zhao
Yu Zhao
GFGuangda Fan
Guangda Fan
AYAiming Yang
Aiming Yang
GZGuanglei Zhang
Guanglei Zhang
Pancreatic cancer is one of the most malignant cancers with high mortality. The rapid on-site evaluation (ROSE) technique can significantly accelerate the diagnostic workflow of pancreatic cancer by immediately analyzing the fast-stained cytopathological images with on-site pathologists. However, the broader expansion of ROSE diagnosis has been hindered by the shortage of experienced pathologists. Deep learning has great potential for the automatic classification of ROSE images in diagnosis. But it is challenging to model the complicated local and global image features. The traditional convolutional neural network (CNN) structure can effectively extract spatial features, while it tends to ignore global features when the prominent local features are misleading. In contrast, the Transformer structure has excellent advantages in capturing global features and long-range relations, while it has limited ability in utilizing local features. We propose a multi-stage hybrid Transformer (MSHT) to combine the strengths of both, where a CNN backbone robustly extracts multi-stage local features at different scales as the attention guidance, and a Transformer encodes them for sophisticated global modeling. Going beyond the strength of each single method, the MSHT can simultaneously enhance the Transformer global modeling ability with the local guidance from CNN features. To evaluate the method in this unexplored field, a dataset of 4240 ROSE images is collected where MSHT achieves 95.68% in classification accuracy with more accurate attention regions. The distinctively superior results compared to the state-of-the-art models make MSHT extremely promising for cytopathological image analysis. The codes and records are available at: https://github.com/sagizty/ Multi-Stage-Hybrid-Transformer.

12 August 2021 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
HXHaoran Xu
Haoran Xu
WYWei Yan
Wei Yan
KLKe Lan
Ke Lan
CMChenbin Ma
Chenbin Ma
DWDi Wu
Di Wu
ZZZhengbo Zhang
Zhengbo Zhang
Background: With the development and promotion of wearable devices and their mobile health (mHealth) apps, physiological signals have become a research hotspot. However, noise is complex in signals obtained from daily lives, making it difficult to analyze the signals automatically and resulting in a high false alarm rate. At present, screening out the high-quality segments of the signals from huge-volume data with few labels remains a problem. Signal quality assessment (SQA) is essential and is able to advance the valuable information mining of signals. Objective: The aims of this study were to design an SQA algorithm based on the unsupervised isolation forest model to classify the signal quality into 3 grades: good, acceptable, and unacceptable; validate the algorithm on labeled data sets; and apply the algorithm on real-world data to evaluate its efficacy. Methods: Data used in this study were collected by a wearable device (SensEcho) from healthy individuals and patients. The observation windows for electrocardiogram (ECG) and respiratory signals were 10 and 30 seconds, respectively. In the experimental procedure, the unlabeled training set was used to train the models. The validation and test sets were labeled according to preset criteria and used to evaluate the classification performance quantitatively. The validation set consisted of 3460 and 2086 windows of ECG and respiratory signals, respectively, whereas the test set was made up of 4686 and 3341 windows of signals, respectively. The algorithm was also compared with self-organizing maps (SOMs) and 4 classic supervised models (logistic regression, random forest, support vector machine, and extreme gradient boosting). One case validation was illustrated to show the application effect. The algorithm was then applied to 1144 cases of ECG signals collected from patients and the detected arrhythmia false alarms were calculated. Results: The quantitative results showed that the ECG SQA model achieved 94.97% and 95.58% accuracy on the validation and test sets, respectively, whereas the respiratory SQA model achieved 81.06% and 86.20% accuracy on the validation and test sets, respectively. The algorithm was superior to SOM and achieved moderate performance when compared with the supervised models. The example case showed that the algorithm was able to correctly classify the signal quality even when there were complex pathological changes in the signals. The algorithm application results indicated that some specific types of arrhythmia false alarms such as tachycardia, atrial premature beat, and ventricular premature beat could be significantly reduced with the help of the algorithm. Conclusions: This study verified the feasibility of applying the anomaly detection unsupervised model to SQA. The application scenarios include reducing the false alarm rate of the device and selecting signal segments that can be used for further research.

27 June 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
FSFan Song
Fan Song
JTJiaxin Tian
Jiaxin Tian
PZPeng Zhang
Peng Zhang
CMChenbin Ma
Chenbin Ma
YSYangyang Sun
Yangyang Sun
GZGuanglei Zhang
Guanglei Zhang
Radiomics refers to the high-throughput extraction of quantitative features from medical images, and is widely used to construct machine learning models for the prediction of clinical outcomes, while feature engineering is the most important work in radiomics. However, current feature engineering methods fail to fully and effectively utilize the heterogeneity of features when dealing with different kinds of radiomics features. In this work, latent representation learning is first presented as a novel feature engineering approach to reconstruct a set of latent space features from original shape, intensity and texture features. This proposed method projects features into a subspace called latent space, in which the latent space features are obtained by minimizing a unique hybrid loss function including a clustering-like loss and a reconstruction loss. The former one ensures the separability among each class while the latter one narrows the gap between the original features and latent space features. Experiments were performed on a multi-center non-small cell lung cancer (NSCLC) subtype classification dataset from 8 international open databases. Results showed that compared with four traditional feature engineering methods (baseline, PCA, Lasso and L2,1-norm minimization), latent representation learning could significantly improve the classification performance of various machine learning classifiers on the independent test set (all p <0.001). Further on two additional test sets, latent representation learning also showed a significant improvement in generalization performance. Our research shows that latent representation learning is a more effective feature engineering method, which has the potential to be used as a general technology in a wide range of radiomics researches.