Sorin Enache

Prof. Sorin Enache

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2024 in Energies
Verified
Journal Article
Open access
PDF file
AAAncuța Mihaela ACIU
Ancuța Mihaela ACIU
Sorin EnacheSorin Enache
Sorin Enache
Maria Cristina NițuMaria Cristina Nițu
Maria Cristina Nițu
Since power transformers are the most important pieces of equipment in electricity transmission and distribution systems, special attention must be paid to their maintenance in order to keep them in good condition for a long time. This paper reviews the main steps in the process of diagnosing the health of power transformer insulation, which involves the science of analysing the gases dissolved in power transformer oil for effective identification of faults. An accurate diagnosis of incipient faults is favourable to sustainable development and necessary to maintain a reliable supply of electricity. The methods presented for fault diagnosis in mineral-oil-immersed power transformers are divided into analytical and graphical methods and have been found to be simple, economical and effective. After describing the methods, both their strengths and weaknesses were identified, and over the years, the methods were complemented to provide highly accurate information, validated by field inspections. This paper focuses on practical information and applications to manage maintenance based on accurate and up-to-date data. The contents of this paper will be of particular use to engineers who manufacture, monitor and/or use high-power transformers in the energy sector, as well as to undergraduate, master’s and PhD students interested in such applications.

29 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
CSCristian Eugeniu Salceanu
Cristian Eugeniu Salceanu
Marcel NicolaMarcel Nicola
Marcel Nicola
Claudiu-Ionel NICOLAClaudiu-Ionel NICOLA
Claudiu-Ionel NICOLA
DODaniel Ocoleanu
Daniel Ocoleanu
CDCătălin Dobrea
Cătălin Dobrea
Sorin EnacheSorin Enache
Sorin Enache
High-voltage fuses are found in most electrical installations, where they are used for overcurrent protection and are the pieces of equipment providing the highest degree of protection for the lowest initial cost. This article focuses on the behavior of high-voltage fuses containing a fuse element entirely made of aluminum. We made high-power linear electrical circuits for experiments on these fuses under the most severe operating conditions. The article presents the construction details of the fuse element and its features, as well as various arc extinguishing media. The heating behavior and time–current characteristics were studied in comparison with fuses made of copper. We obtained the maximum instantaneous value of the current reached during interruption for a 24 kV, 50 kA, 50 A fuse, as well as the value of the minimum breaking current.

11 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
Sorin EnacheSorin Enache
Sorin Enache
IVIon Vlad
Ion Vlad
MEMonica Adela Enache
Monica Adela Enache
Modern electrical traction uses asynchronous motors for driving railway vehicles because these motors have a lot of advantages in comparison with the classical, direct current motors. Reducing active and reactive electrical energy consumption is a concern in the case of these motors, meaning a decrease in exploitation costs. The research carried out shows, by results and simulations, the effects of the geometry optimization for the stator and rotor lamination and emphasizes how much the total and exploitation costs. Cross geometry optimization means preserving constant electromagnetic stresses, using the same gauge dimensions, preserving the constant ampere-turn for a pole pair, having a maximum torque exceeding the imposed limit, and increasing the air-gap magnetic induction. The results obtained indicatea decrease in the total cost, by 42,600 € (12.31%), for a asynchronous tractionmotor in comparison with the existing variant.

1 March 2019
Verified
Conference Paper
Closed access
MEMonica-Adela Enache
Monica-Adela Enache
ACAurel Campeanu
Aurel Campeanu
Sorin EnacheSorin Enache
Sorin Enache
IVIon Vlad
Ion Vlad
The research we carried out is justified by the fact that the present technical and economic context needs an interference between the asynchronous motor design, afferent to the steady-state conditions and its dynamic behaviour. Carrying out some performant electrical drives, with asynchronous motors, in steady-state conditions and in dynamic state, requires a preliminary knowing of the motor response. The analysis has been carried out with a high-power asynchronous motor, which drives the bucket-holder wheel of a surface mining excavator. The high inertia moment causes a long starting, with voltage drops and losses in the supply wire. The duration of the no-load starting, tp=1.36s (in load tp=4.2s) and the afferent current shock, Ip=3.12*In have been exactly established by the research. The simulations carried out provide useful quantitative and qualitative information, in order to establish the optimum constructive solution for steady-state conditions and dynamic state. The paper might be a theoretical and practical support, based on using advanced numerical methods and the afferent software.

29 August 2024 in Energies
Verified
Journal Article
Open access
PDF file
Sorin EnacheSorin Enache
Sorin Enache
MEMonica-Adela Enache
Monica-Adela Enache
IVIon Vlad
Ion Vlad
In modern electric traction, direct current traction motors have been replaced with asynchronous motors with a short-circuited rotor. The justification is that asynchronous motors are more reliable, cheaper, and have smaller weights and dimensions, so they are more sustainable. In order to start and adjust the speed required in traction, these motors are powered from the contact line using a transformer and a static voltage and frequency converter. As a result, you can use green electricity produced with wind power plants or solar energy converted with photovoltaic panels, increasing sustainability because the consumption of traditional fuels is reduced. This paper presents various simulations emphasizing the negative effects of the distorting regime, with concrete results. The quality of the simulations carried out is increased by using a mathematical model, which uses the variable parameters of the motor dependent on the modulation of the current and the magnetic saturation. In modern 1500 kW electric locomotives, the traction motors are powered by static converters, which means an increase in losses when operating at nominal load on the motors by 38.7 kW and 217.8 kVAR compared to the sinusoidal three-phase power supply. Thus, the research carried out provides qualitatively and quantitatively correct simulations of the non-sinusoidal regime related to the asynchronous traction motor in order to increase the sustainability of this traction system.

23 May 2024 in Energies
Verified
Journal Article
Open access
PDF file
CSCristian Eugeniu Salceanu
Cristian Eugeniu Salceanu
Sorin EnacheSorin Enache
Sorin Enache
CDCătălin Dobrea
Cătălin Dobrea
DIDaniela Iovan
Daniela Iovan
DODaniel Ocoleanu
Daniel Ocoleanu
MIMihai Ionescu
Mihai Ionescu
If an R.M.U. (Ring Main Unit) cubicle is installed, operated and maintained in accordance with current standards and the manufacturer’s instructions, the likelihood of internal arcing is reduced, but should not be completely ignored. This article outlines the experimental situations in which arcing can occur and the catastrophic effects seen if R.M.U. is not properly designed for this type of damage. This type of failure can be caused by a fault, abnormal operating conditions or a malfunction and represents a danger during its installation and to persons present. The situations in which this type of failure can occur are presented and experimentally analysed: bi-phase internal arcing in the connections compartment, three-phase internal arcing in the switching compartment, internal arcing in the fuse compartment and single-phase arcing between a phase and the switchgear enclosure.