Mathieu Delorme

Dr. Mathieu Delorme

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Critical Care Medicine
Verified
Journal Article
Closed access
PDF file
MDMathieu Delorme
Mathieu Delorme
PBPierre-Alexandre Bouchard
Pierre-Alexandre Bouchard
MSMathieu Simon
Mathieu Simon
SSSerge Simard
Serge Simard
FLFrançois Lellouche
François Lellouche
Objectives: High-flow nasal cannula is increasingly used in the management of respiratory failure. However, little is known about its impact on respiratory effort, which could explain part of the benefits in terms of comfort and efficiency. This study was designed to assess the effects of high-flow nasal cannula on indexes of respiratory effort (i.e., esophageal pressure variations, esophageal pressure-time product/min, and work of breathing/min) in adults. Design: A randomized controlled crossover study was conducted in 12 patients with moderate respiratory distress (i.e., after partial recovery from an acute episode, allowing physiologic measurements). Setting: Institut Universitaire de Cardiologie et de Pneumologie de Québec, QC, Canada. Subjects: Twelve adult patients with respiratory distress symptoms were enrolled in this study. Interventions: Four experimental conditions were evaluated: baseline with conventional oxygen therapy and high-flow nasal cannula at 20, 40, and 60 L/min. The primary outcomes were the indexes of respiratory effort (i.e., esophageal pressure variations, esophageal pressure-time product/min, and work of breathing/min). Secondary outcomes included tidal volume, respiratory rate, minute volume, dynamic lung compliance, inspiratory resistance, and blood gases. Measurements and Main Results: Esophageal pressure variations decreased from 9.8 (5.8–14.6) cm H2O at baseline to 4.9 (2.1–9.1) cm H2O at 60 L/min (p = 0.035). Esophageal pressure-time product/min decreased from 165 (126–179) to 72 (54–137) cm H2O • s/min, respectively (p = 0.033). Work of breathing/min decreased from 4.3 (3.5–6.3) to 2.1 (1.5–5.0) J/min, respectively (p = 0.031). Respiratory pattern variables and capillary blood gases were not significantly modified between experimental conditions. Dynamic lung compliance increased from 38 (24–64) mL/cm H2O at baseline to 59 (43–175) mL/cm H2O at 60 L/min (p = 0.007), and inspiratory resistance decreased from 9.6 (5.5–13.4) to 5.0 (1.0–9.1) cm H2O/L/s, respectively (p = 0.07). Conclusions: High-flow nasal cannula, when set at 60 L/min, significantly reduces the indexes of respiratory effort in adult patients recovering from acute respiratory failure. This effect is associated with an improvement in respiratory mechanics.

13 October 2021 in Respiratory Medicine
Verified
Journal Article
Closed access
BBBenoit Bouteleux
Benoit Bouteleux
PHPauline Henrot
Pauline Henrot
RERachel Ernst
Rachel Ernst
LGLéo Grassion
Léo Grassion
CRChantal Raherison-Semjen
Chantal Raherison-Semjen
MDMathieu Delorme
Mathieu Delorme

1 September 2015 in Best Practice & Research Clinical Anaesthesiology
Verified
Journal Article
Closed access
FLFrançois Lellouche
François Lellouche
MDMathieu Delorme
Mathieu Delorme
JBJean Bussières
Jean Bussières
AOAlexandre Ouattara
Alexandre Ouattara

14 April 2020 in Respiratory Care
Verified
Journal Article
Closed access
PDF file
MDMathieu Delorme
Mathieu Delorme
PBPierre-Alexandre Bouchard
Pierre-Alexandre Bouchard
MSMathieu Simon
Mathieu Simon
SSSerge Simard
Serge Simard
FLFrançois Lellouche
François Lellouche
BACKGROUND: High-flow nasal cannula (HFNC) is increasingly used in the management of acute and chronic respiratory failure. Little is known about the optimal settings for HFNC. This study was designed to assess the dose effect of HFNC on respiratory effort indexes and respiratory patterns in spontaneously breathing adults. METHODS: A randomized controlled crossover study was conducted in 10 healthy subjects. Five experimental conditions were evaluated: baseline with no therapy; 5 L/min with conventional nasal prongs; and HFNC at 20, 40, and 60 L/min. The primary outcomes were the indexes of respiratory effort (ie, esophageal pressure swing [ΔP es ], esophageal pressure-time product, and work of breathing). Secondary outcomes included breathing pattern parameters and blood gases. Dead-space ventilation and washout were calculated based on minute ventilation, breathing frequency, and Radford equations. RESULTS: ΔP es increased from median (interquartile range [IQR] 3.2 (2.2–3.6) cm H 2 O at baseline to median (IQR) 5.7 (4.6–6.8) cm H 2 O at 60 L/min ( P < .001). Neither esophageal pressure-time product nor work of breathing were modified during the tested conditions. The minute volume was significantly reduced at 40 and 60 L/min compared with baseline (P = .04), mostly driven by an important and dose-dependent reduction in breathing frequency, from median (IQR) 16 (15–18) breaths/min at baseline, to median (IQR) 8 (7–10) breaths/min at 60 L/min ( P < .001). Capillary P CO 2 was stable in all the tested conditions. The calculated dead-space ventilation was reduced by half with HFNC. CONCLUSIONS: HFNC did not significantly modify work of breathing in healthy subjects. However, a significant reduction in the minute volume was achieved, capillary P CO 2 remaining constant, which suggests a reduction in dead-space ventilation with flows > 20 L/min. (ClinicalTrials.gov registration NCT02495675).

1 September 2022 in Thorax
Verified
Journal Article
Open access
PDF file
MDMathieu Delorme
Mathieu Delorme
CRChristian Reveillere
Christian Reveillere
CDChristian Devaux
Christian Devaux
SSSandrine Segovia-Kueny
Sandrine Segovia-Kueny
FLFrédéric Lofaso
Frédéric Lofaso
GBGhilas Boussaid
Ghilas Boussaid
This cross-sectional study evaluated health-related quality of life (HRQoL) in patients with slowly progressive neuromuscular disorders dependent on mechanical ventilation (MV; ≥16 hours/day). 119 participants, with 9 years (25th–75th percentiles: 4–15 years) of MV dependence, were included. MV was applied via a tracheostomy in 80 participants (67.2%) and non-invasive interfaces in 39 participants (32.8%), including 28 participants (71.8%) with daytime mouthpiece ventilation. HRQoL was rated good or excellent by 81 participants (68.1%), independently from age, diagnosis or respiratory autonomy. On multivariate analysis, time since MV initiation, independence from family member(s), residence in a rural area, ability to go outdoors with MV and tracheostomy were associated with better HRQoL.

11 October 2022 in Respiratory Care
Verified
Journal Article
Closed access
PDF file
MDMathieu Delorme
Mathieu Delorme
KLKarl Leroux
Karl Leroux
ALAntoine Leotard
Antoine Leotard
GBGhilas Boussaid
Ghilas Boussaid
HPHelene Prigent
Helene Prigent
FLFrederic Lofaso
Frederic Lofaso
BACKGROUND: Noninvasive ventilation (NIV) is the reference standard treatment for most situations of chronic respiratory failure. NIV settings must be titrated to both preserve upper-airway patency and control hypoventilation. Automatic adjustment of pressure support (PS) and expiratory positive airway pressure (EPAP) may facilitate the initiation and follow-up of domiciliary NIV. However, whether the automatic-adjustment algorithms embedded into current devices accurately detect, respond to, and score common sleep-related respiratory events remains unclear. METHODS: A bench was set up to simulate central hypopnea (CH), central apnea (CA), obstructive hypopnea (OH), and obstructive apnea (OA). Four home ventilators were evaluated, with their dedicated modes for automatic PS and EPAP adjustment. RESULTS: All 4 devices increased PS during CH, CA, and OH. However, PS adjustment varied widely in magnitude, with tidal volumes within 100 ± 20% of the target being provided by only 3 devices for CH, one for CA, and one for OH. Two devices increased EPAP for OH and 3 for OA, including one that also increased EPAP for CA. Only 2 devices scored residual hypopnea after simulated CA, and only one scored a residual event after OH. One device scored no event. CONCLUSIONS: Current NIV devices differed markedly in their responses to, and reporting of, standardized sleep-related respiratory events. Further improvements in embedded NIV algorithms are needed to allow more widespread out-of-laboratory initiation and follow-up of NIV.