In this study, diagnosis of a 300-MW combined cycle power plant under faulty conditions was performed using a thermoeconomic method called modified productive structure analysis. The malfunction and dysfunction, unit cost of irreversibility and lost cost flow rate for each component were calculated for the cases of pre-fixed malfunction and the reference conditions. A commercial simulating software, GateCycleTM (version 6.1.2), was used to estimate the thermodynamic properties under faulty conditions. The relative malfunction (RMF) and the relative difference in the lost cost flow rate between real operation and reference conditions (RDLC) were found to be effective indicators for the identification of faulty components. Simulation results revealed that 0.5% degradation in the isentropic efficiency of air compressor, 2% in gas turbine, 2% in steam turbine and 2% degradation in energy loss in heat exchangers can be identified. Multi-fault scenarios that can be detected by the indicators were also considered. Additional lost exergy due to these types of faulty components, that can be detected by RMF or RDLC, is less than 5% of the exergy lost in the components in the normal condition.
30 September 2020 in Journal of the Korean Society of Manufacturing Process Engineers
Conventional water mist systems require high-pressure pumps and complex piping networks to generate fine water droplets, which often results in high installation costs and maintenance difficulties. Recently, a water mist system with ultrasonic waves has been proposed as a viable alternative system to address those limitations. However, there is a lack of experimental data for evaluating the fire suppression performance of water mist systems using ultrasonic waves. Therefore, in this study, a simplified water mist system with an ultrasonic wave was suggested for evaluating the fire suppression performance. Subsequently, a reduced-scale room corner test (RCT) was conducted to investigate suppression performance under various fire sizes and suppression conditions. The experimental cases were classified according to pool size, door condition, and operation of the ultrasonic water mist system. Ultimately, fire suppression performance was quantitatively evaluated using performance indices derived from fire duration and indoor temperature variation. The results demonstrate that the ultrasonic water mist system effectively suppresses fires through combined cooling and oxygen-blocking effects, while significantly reducing indoor temperature compared to oxygen-blocking suppression. The proposed performance indices enable quantitative comparison of suppression effectiveness and confirm the feasibility of ultrasonic water mist systems as an alternative to conventional high-pressure water mist systems.
30 August 2026 in Journal of the Korean Society of Manufacturing Process Engineers