Lei Hua

Prof. Dr. Lei Hua

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2016 in ACS Nano
Verified
Journal Article
Closed access
YLYanhong Lu
Yanhong Lu
YYYang Yang
Yang Yang
TZTengfei Zhang
Tengfei Zhang
ZGZhen Ge
Zhen Ge
HCHuicong Chang
Huicong Chang
YCYongsheng Chen
Yongsheng Chen

9 September 2016 in Analytical Chemistry
Verified
Journal Article
Closed access
YWYan Wang
Yan Wang
JJJichun Jiang
Jichun Jiang
LHLei Hua
Lei Hua
KHKeyong Hou
Keyong Hou
YXYuanyuan Xie
Yuanyuan Xie
HLHaiyang Li
Haiyang Li

3 December 2012 in Analytical Chemistry
Verified
Journal Article
Closed access
SCShasha Cheng
Shasha Cheng
JDJian Dou
Jian Dou
WWWeiguo Wang
Weiguo Wang
CCChuang Chen
Chuang Chen
LHLei Hua
Lei Hua
HLHaiyang Li
Haiyang Li

2 June 2011 in Analytical Chemistry
Verified
Journal Article
Closed access
LHLei Hua
Lei Hua
QWQinghao Wu
Qinghao Wu
KHKeyong Hou
Keyong Hou
HCHuapeng Cui
Huapeng Cui
PCPing Chen
Ping Chen
HLHaiyang Li
Haiyang Li

16 October 2014 in Scientific Reports
Verified
Journal Article
Open access
LPLiying Peng
Liying Peng
LHLei Hua
Lei Hua
WWWeiguo Wang
Weiguo Wang
QZQinghua Zhou
Qinghua Zhou
HLHaiyang Li
Haiyang Li
New techniques for the field detection of inorganic improvised explosive devices (IEDs) are urgently developed. Although ion mobility spectrometry (IMS) has been proved to be the most effective method for screening organic explosives, it still faces a major challenge to detect inorganic explosives owing to their low volatilities. Herein, we proposed a strategy for detecting trace inorganic explosives by thermal desorption ion mobility spectrometry (TD-IMS) with sample-to-sample analysis time less than 5[emsp14]s based on in-situ acidification on the sampling swabs. The responses for typical oxidizers in inorganic explosives, such as KNO3, KClO3 and KClO4 were at least enhanced by a factor of 3000 and their limits of detection were found to be subnanogram. The common organic explosives and their mixtures with inorganic oxidizers were detected, indicating that the acidification process did not affect the detection of organic explosives. Moreover, the typical inorganic explosives such as black powders, firecrackers and match head could be sensitively detected as well. These results demonstrated that this method could be easily employed in the current deployed IMS for on-site sensitive detection of either inorganic explosives or organic ones.

26 April 2016 in Analytical Chemistry
Verified
Journal Article
Closed access
JJJichun Jiang
Jichun Jiang
YWYan Wang
Yan Wang
KHKeyong Hou
Keyong Hou
LHLei Hua
Lei Hua
PCPing Chen
Ping Chen
HLHaiyang Li
Haiyang Li