Lina Hamabe

Dr. Lina Hamabe

Veterinary Surgery, Tokyo University of Agriculture and Technology, Tokyo, Japan
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2021 in Materials Today Bio
Verified
Journal Article
Open access
H EH E
H E
Eman A. MadyEman A. Mady
Eman A. Mady
LHLina Hamabe
Lina Hamabe
Amira AbugomaaAmira Abugomaa
Amira Abugomaa
KSKazumi Shimada
Kazumi Shimada
Ryou TanakaRyou Tanaka
Ryou Tanaka
Recently, biomedicine and tissue regeneration have emerged as great advances that impacted the spectrum of healthcare. This left the door open for further improvement of their applications to revitalize the impaired tissues. Hence, restoring their functions. The implementation of therapeutic protocols that merge biomimetic scaffolds, bioactive molecules, and cells plays a pivotal role in this track. Smart/stimuli-responsive hydrogels are remarkable three-dimensional (3D) bioscaffolds intended for tissue engineering and other biomedical purposes. They can simulate the physicochemical, mechanical, and biological characters of the innate tissues. Also, they provide the aqueous conditions for cell growth, support 3D conformation, provide mechanical stability for the cells, and serve as potent delivery matrices for bioactive molecules. Many natural and artificial polymers were broadly utilized to design these intelligent platforms with novel advanced characteristics and tailored functionalities that fit such applications. In the present review, we highlighted the different types of smart/stimuli-responsive hydrogels with emphasis on their synthesis scheme. Besides, the mechanisms of their responsiveness to different stimuli were elaborated. Their potential for tissue engineering applications was discussed. Furthermore, their exploitation in other biomedical applications as targeted drug delivery, smart biosensors, actuators, 3D and 4D printing, and 3D cell culture were outlined. In addition, we threw light on smart self-healing hydrogels and their applications in biomedicine. Eventually, we presented their future perceptions in biomedical and tissue regeneration applications. Conclusively, current progress in the design of smart/stimuli-responsive hydrogels enhances their prospective to function as intelligent, and sophisticated systems in different biomedical applications.

3 August 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
AYAkira Yairo
Akira Yairo
Ahmed S. MandourAhmed S. Mandour
Ahmed S. Mandour
KMKatsuhiro Matsuura
Katsuhiro Matsuura
TYtomohiko yoshida
tomohiko yoshida
DMDanfu Ma
Danfu Ma
Ryou TanakaRyou Tanaka
Ryou Tanaka
Evaluation of diastolic function is a pivotal challenge due to limitations of the conventional echocardiography, especially when the heart rate is rapid as in rats. Currently, by using color M-mode echocardiography (CMME), intraventricular pressure difference (IVPD) and intraventricular pressure gradient (IVPG) in early diastole can be generated and are available as echocardiographic indices. These indices are expected to be useful for the early diagnosis of heart failure (HF), especially diastolic dysfunction. There have not been any studies demonstrating changes in IVPD and IVPG in response to changes in loading conditions in rats. Therefore, the present study aims to evaluate CMME-derived IVPD and IVPG changes in rats under various loading conditions. Twenty rats were included, divided into two groups for two different experiments, and underwent jugular vein catheterization under inhalational anesthetics. Conventional echocardiography, CMME, and 2D speckle tracking echocardiography were measured at the baseline (BL), after intravenous infusion of milrinone (MIL, n = 10), and after the infusion of hydroxyethyl starch (HES, n = 10). Left ventricular IVPD and IVPG were calculated from color M-mode images and categorized into total, basal, mid-to-apical, mid, and apical parts, and the percentage of the corresponding part was calculated. In comparison to the BL, the ejection fraction, mid-to-apical IVPG, mid IVPG, and apical IVPD were significantly increased after MIL administration (p < 0.05); meanwhile, the end-diastolic volume, E-wave velocity, total IVPD, and basal IVPD were significantly increased with the administration of HES (p < 0.05). The increase in mid-to-apical IVPD, mid IVPD, and apical IVPD indicated increased relaxation. A significant increase in basal IVPD reflected volume overloading by HES. CMME-derived IVPD and IVPG are useful tools for the evaluation of various loading conditions in rats. The approach used in this study provides a model for continuous data acquisition in chronic cardiac disease models without drug testing.

10 August 2021 in Animals
Verified
Journal Article
Open access
PDF file
LHLina Hamabe
Lina Hamabe
Ahmed S. MandourAhmed S. Mandour
Ahmed S. Mandour
KSKazumi Shimada
Kazumi Shimada
AUAkiko Uemura
Akiko Uemura
ZYZeki Yilmaz
Zeki Yilmaz
Ryou TanakaRyou Tanaka
Ryou Tanaka
Two-dimensional speckle-tracking echocardiography (2D–STE) is an advanced echocardiographic technique based on deformation imaging that allows comprehensive evaluation of the myocardial function. Clinical application of 2D–STE holds great potential for its ability to provide valuable information on both global and regional myocardial function and to quantify cardiac rotation and synchronicity, which are not readily possible with the conventional echocardiography. It has gained growing importance over the past decade, especially in human medicine, and its application includes assessment of myocardial function, detection of subclinical myocardial dysfunction and serving as a prognostic indicator. This review illustrates the fundamental concepts of deformation analysis and gives an overview of the current understanding and its clinical application of this technique in veterinary medicine, with a focus on early detection of left ventricular (LV) dysfunction in dogs.

28 December 2021 in Animals
Verified
Journal Article
Open access
PDF file
KSKenta Sasaki
Kenta Sasaki
DMDanfu Ma
Danfu Ma
Ahmed S. MandourAhmed S. Mandour
Ahmed S. Mandour
YOYusuke Ozai
Yusuke Ozai
TYtomohiko yoshida
tomohiko yoshida
Ryou TanakaRyou Tanaka
Ryou Tanaka
Mitral valve regurgitation is a common canine heart disease. Transcatheter Edge-to-Edge Repair (TEER) is a transcatheter, edge-to-edge mitral repair device that uses a hybrid approach. No detailed information has been published on the hemodynamic effect of TEER on cardiac function. The aim of this report is to provide a longitudinal observation of the cardiac functional changes observed after TEER implantation in normal dogs using traditional, two-dimensional speckle tracking, and color M-mode echocardiographic methods. In the current report, TEER was implanted into two healthy dogs under general anesthesia. An echocardiographic examination was performed at baseline and weekly postoperative follow-ups were conducted until the fourth week. Successful TEER implantation was achieved with a short operation time (98 and 63 min) in the two dogs. Functional mitral valve regurgitation, elevated E/e’ ratio, elevated radial strain, and stable intraventricular pressure gradients (IVPG) were observed after the operation in the dogs. Mild non progressive mitral valve stenosis was observed in both dogs. TEER is a minimally invasive method for mitral valve surgery that necessitates more clinical trials. With longitudinal observation of heart function using novel approaches, better outcomes will be expected.

1 June 2011 in Journal of Feline Medicine and Surgery
Verified
Journal Article
Closed access
SNShu Nakao
Shu Nakao
Ryou TanakaRyou Tanaka
Ryou Tanaka
LHLina Hamabe
Lina Hamabe
SSShuji Suzuki
Shuji Suzuki
HHHuai-Che Hsu
Huai-Che Hsu
NMNoboru Machida
Noboru Machida
An 11-month-old, 3 kg, female domestic shorthair cat was referred to evaluate cardiac structure and function. Echocardiography revealed the membrane dividing the left atrium into two chambers, a large defect in the lower part of the atrial septum, and turbulent blood flow from the distal left atrium into the right atrium. These findings suggested cor triatriatum sinister (CTS) with incomplete atrioventricular septal defect (AVSD). The cat was treated with medications for management of congestive heart failure. In the end, she died from right-sided heart failure 17 months after the initial presentation. At necropsy, a fibromuscular membrane with a round orifice in the left atrium and an ostium primum defect were confirmed, and the definitive diagnosis of CTS with incomplete AVSD was made. To our knowledge, this study presents the first case report of CTS with incomplete AVSD in a cat.

3 April 2025 in Animals
Verified
Journal Article
Open access
PDF file
XZXinyue Zhao
Xinyue Zhao
Ryou TanakaRyou Tanaka
Ryou Tanaka
Ryou TanakaRyou Tanaka
Ryou Tanaka
KSKazumi Shimada
Kazumi Shimada
LHLina Hamabe
Lina Hamabe
Remote vital sensing in veterinary medicine is a relatively new area of practice, which involves the acquisition of data without invasion of the body cavities of live animals. This paper aims to review several technologies in remote vital sensing: infrared thermography, remote photoplethysmography (rPPG), radar, wearable sensors, and computer vision and machine learning. In each of these technologies, we outline its concepts, uses, strengths, and limitations in multiple animal species, and its potential to reshape health surveillance, welfare evaluation, and clinical medicine in animals. The review also provides information about the problems associated with applying these technologies, including species differences, external conditions, and the question of the reliability and classification of these technologies. Additional topics discussed in this review include future developments such as the use of artificial intelligence, combining different sensing methods, and creating monitoring solutions tailored to specific animal species. This contribution gives a clear understanding of the status and future possibilities of remote vital sensing in veterinary applications and stresses the importance of that technology for the development of the veterinary field in terms of animal health and science.