Acute reversible left ventricular wall motion abnormalities mimicking myocardial stunning have been reported with noncardiac disease and their coronary angiograms did not demonstrate organic stenosis or vasospasm in the epicardial coronary arteries. Thus, this mechanism has not yet been fully clarified. Two patients are reported as demonstrating acute reversible wall motion abnormalities after noncardiac disease. The electrocardiographic and echocardiographic findings mimicked myocardial stunning and confirmed the previous reports. The coronary angiograms did not show any corresponding coronary stenosis or vasospasm, but did show a reduced coronary flow reserve. Cardiac metaiodobenzylguanidine scintigraphy demonstrated regional defects involving the apex, a decreased heart/mediastinum ratio and an enhanced washout rate, which partially returned to normal after 3 months. Microvascular dysfunction and sympathetic nervous abnormalities might be responsible for the reversible contractile impairment.
1 June 2010 in American Journal of Cardiovascular Drugs
Background The elevated D-dimer value is one of the clues used to diagnose acute aortic dissection (AAD), but the rapid D-dimer assay is not used at all emergency hospitals. The fibrinogen/fibrin degradation products (FDP) value is also an indicator of enhanced fibrinolysis and may therefore be a useful marker in patients with AAD. In addition, the association between FDP values and partial thrombosis of the false lumen is not elucidated. Patients The present study enrolled 50 patients (66.5±11.2 years of age; median, 66.5 years of age, male subjects comprised 60.0% of the series) with AAD who were admitted to the hospital between July 2005 and December 2007 and 57 patients with acute myocardial infarction (AMI; 70.8±10.4 years of age; median, 71.0 years of age, male subjects comprised 71.9% of the current series) served as a control group. Results The FDP values (μg/mL) in patients with AAD were significantly higher than those of AMI patients (40.2±78.6; median, 14.7 vs. 5.2±9.8; median, 1.7, p<0.001). A receiver operating characteristic curves analysis showed that an elevated FDP level (2.05 μg/mL) was predictive of a diagnosis of AAD with a sensitivity and specificity of 98% and 54%, respectively. The FDP levels of patients (n=14) who had partial thrombosis of the false lumen were significantly higher than in discharged patients without a surgical repair (n=21) who had a patent or complete thrombosis of the false lumen (35.8±43.2; median, 18.8 vs. 14.0±21.3; median, 5.5, p=0.01). Conclusion The measurement of FDP may therefore be useful for the initial assessment of patients with suspected AAD and in the prediction of thrombotic status of the false lumen.
1 November 2011 in Cardiovascular Revascularization Medicine