Feng Ren

Dr. Feng Ren

Suzhou Institute of Nano-tech and Nano-bionics, Suzhou, Anhui, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2024 in Biomaterials
Verified
Journal Article
Closed access
HLHanghang Liu
Hanghang Liu
MHMenglong Hua
Menglong Hua
YHYaobao Han
Yaobao Han
LYLi Yang
Li Yang
ZHZhongshi Huang
Zhongshi Huang
ZLZhen Li
Zhen Li

16 June 2024 in Chemosensors
Verified
Journal Article
Open access
PDF file
MLMeng Li
Meng Li
TLTuanwei Li
Tuanwei Li
FWFeng Wu
Feng Wu
FRFeng Ren
Feng Ren
SXSumei Xue
Sumei Xue
Chunyan LiChunyan Li
Chunyan Li
Tumors represent a significant threat to human health, underscoring the critical need for effective treatment strategies. However, conventional drug therapies are hampered by imprecise delivery, potentially leading to inadequate efficacy and severe side effects. The strategic development of nanomedicines is believed to harbor enormous potential for enhancing drug safety and efficacy, especially for precise, tumor-targeted therapies. Nevertheless, the fate of these nanomedicines within the human body is intricately governed by various physiological barriers and complex environments, posing challenges to predicting their behaviors. Near-infrared II (NIR-II, 1000–1700 nm) fluorescence imaging technology serves as a non-invasive, real-time monitoring method that can be applied for the precise evaluation of nanomedicine delivery in cancer therapy due to its numerous advantages, including high tissue penetration depth, high spatiotemporal resolution, and high signal-to-noise ratio. In this review, we comprehensively summarize the pivotal role of NIR-II fluorescence imaging in guiding the intratumoral precise delivery of nanomedicines and shed light on its current applications, challenges, and promising prospects in this field.

4 August 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
FRFeng Ren
Feng Ren
TLTuanwei Li
Tuanwei Li
TYTingfeng Yao
Tingfeng Yao
GCGuangcun Chen
Guangcun Chen
Chunyan LiChunyan Li
Chunyan Li
Qiangbin WangQiangbin Wang
Qiangbin Wang
The pathological process involves a range of intrinsic biochemical markers. The detection of multiple biological parameters is imperative for providing precise diagnostic information on diseases. In vivo multichannel fluorescence biosensing facilitates the acquisition of biochemical information at different levels, such as tissue, cellular, and molecular, with rapid feedback, high sensitivity, and high spatiotemporal resolution. Notably, fluorescence imaging in the near-infrared-II (NIR-II) window (950–1700 nm) promises deeper optical penetration depth and diminished interferential autofluorescence compared with imaging in the visible (400–700 nm) and near-infrared-I (NIR-I, 700–950 nm) regions, making it a promising option for in vivo multichannel biosensing toward clinical practice. Furthermore, the use of advanced NIR-II fluorophores supports the development of biosensing with spectra-domain, lifetime-domain, and fluorescence-lifetime modes. This review summarizes the versatile designs and functions of NIR-II fluorophores for in vivo multichannel biosensing in various scenarios, including biological process monitoring, cellular tracking, and pathological analysis. Additionally, the review briefly discusses desirable traits required for the clinical translation of NIR-II fluorophores such as safety, long-wavelength emission, and clear components.

24 March 2026 in Biomaterials
Verified
Journal Article
Closed access
XZXuedong Zhang
Xuedong Zhang
ZHZhongshi Huang
Zhongshi Huang
YHYaobao Han
Yaobao Han
MHMenglong Hua
Menglong Hua
JTJiamin Tan
Jiamin Tan
ZLZhen Li
Zhen Li