Jian Jiang

Jian Jiang


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2023 in Stem Cell Reviews and Reports
Verified
Journal Article
Closed access
PDF file
NJNizhou Jiang
Nizhou Jiang
XTXiliang Tian
Xiliang Tian
QWQuanxiang Wang
Quanxiang Wang
JHJiayu Hao
Jiayu Hao
JJJian Jiang
Jian Jiang
HWHong Wang
Hong Wang

25 September 2023 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
JHJiayu Hao
Jiayu Hao
XTXianSheng Tang
XianSheng Tang
NJNizhou Jiang
Nizhou Jiang
HWHong Wang
Hong Wang
JJJian Jiang
Jian Jiang
Objective: Using finite element analysis to identify the optimal internal fixation method for oblique lateral lumbar interbody fusion (OLIF), providing guidance for clinical practice.Methods: A finite element model of the L4 – L5 segment was created. Five types of internal fixations were simulated in the generated L4-L5 finite element (FE) model. Then, six loading scenarios, i.e., flexion, extension, left-leaning, right-leaning, rotate left, and rotate right, were simulated in the FE models with different types of fixations. The biomechanical stability of the spinal segment after different fixations was investigated.Results: Regarding the range of motion (ROM) of the fused segment, OLIF + Bilateral Pedicle Screws (BPS) has a maximum ROM of 1.82° during backward bending and the smallest ROM in all directions of motion compared with other models. In terms of the von Mises stress distribution on the cage, the average stress on every motion direction of OLIF + BPS is about 17.08MPa, and of OLIF + Unilateral Vertebral Screw - Pedicle Screw (UVS-PS) is about 19.29 MPa. As for the von Mises stress distribution on the internal fixation, OLIF + BPS has the maximum internal fixator stress in left rotation (31.85 MPa) and OLIF + Unilateral Pedicle Screw (UPS) has the maximum internal fixator stress in posterior extension (76.59 MPa). The data of these two models were smaller than those of other models.Conclusion: OLIF + BPS provides the greatest biomechanical stability, OLIF + UPS has adequate biomechanical stability, OLIF + UVS-PS is inferior to OLIF + UPS synthetically, and OLIF + Double row vertical screw (DRVS) and Individual OLIF (IO) do not present significant obvious advantages.

2 December 2025 in Chemical Communications
Verified
Journal Article
Closed access
PDF file
LHLei Hao
Lei Hao
XHXiaoli Huo
Xiaoli Huo
YZYi Zhang
Yi Zhang
HSHaoyang Song
Haoyang Song
YXYing Xie
Ying Xie
Haidong LiHaidong Li
Haidong Li
In this study, we report a mitochondria-anchored, aggregation-induced emission photosensitizer named Kl-CHO, which could induce pyroptosis for enhanced photodynamic immunotherapy.

17 February 2026 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
YLYongtao Lyu
Yongtao Lyu
VSVolha Siniauskaya
Volha Siniauskaya
JJJian Jiang
Jian Jiang
HWHao Wang
Hao Wang
LMLingqi Meng
Lingqi Meng
MKMohammed Rafiq Abdul Kadir
Mohammed Rafiq Abdul Kadir
Introduction: Current intestinal stents used to restore patency face limitations due to the rigidity of metal structures and the premature degradation of biopolymer alternatives. Therefore, there is a critical need to develop stents that are flexible, radially strong, and able to adapt to the dynamic conditions within the body. Methods: This study introduces a novel tubular mechanical metamaterial featuring a sign-switchable Poisson’s ratio and tunable mechanical properties, achieved by integrating hexagonal unit cells with positive Poisson’s ratio and re-entrant unit cells with negative Poisson’s ratio. Experimental uniaxial compression tests and finite element analyses were performed to validate the proposed design and assess its mechanical performance. Results: The structure exhibits a negative Poisson’s ratio under tensile loading across all configurations, whereas under compression, the Poisson’s ratio was transited from negative to positive due to self-contact between triangular struts, enabling the distinctive sign-switching behavior. Experimental uniaxial compression tests and finite element analyses were performed to validate the proposed design and assess its mechanical performance. Results reveal that the geometric gap between the horizontal struts in the concave unit cells serves as a crucial tuning parameter: increasing this gap delays the onset of sign‐switching during compression while exerting minimal influence on the tensile response. The stiffness, yield strength, and energy absorption capacity are shown to be highly adjustable through this geometric control. Discussion: Overall, the metamaterial demonstrates superior energy absorption and tunable stiffness, making it a promising candidate for applications in intestinal stents.

5 January 2026 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
HWHao Wang
Hao Wang
YLYongtao Lyu
Yongtao Lyu
JJJian Jiang
Jian Jiang
FZFeihu Zhao
Feihu Zhao
SBSergei Bosiakov
Sergei Bosiakov
HZHanxing Zhu
Hanxing Zhu
Introduction: Bone scaffolds are widely used for repairing bone defects. As a biomimetic structure for bone scaffolds, the triply periodic minimal surface (TPMS) structure is an ideal choice. To evaluate/characterize the mechanical properties of TPMS structures, multiple methods (e.g., via experiment or theoretical analysis) can be used. Each method has its advantages and disadvantages. Using approximate analytical approach, the mechanical properties of structures can be predicted quickly and efficiently. Therefore, it is necessary to determine the applicable range to ensure that the calculated mechanical properties of TPMS structures with varying porosity and strut orientation are acceptable. Methods: In this paper, approximate analytical prediction of elastic properties of TPMS structures (i.e., Diamond) with varying porosities and strut orientations was investigated, and finite element (FE) method and theory of elasticity were compared with the approximate analytical approach. The ranges for porosity were from 70% to 90%. The ranges for orientation were defined by rotating the scaffold from 0° to 90° along the [100] and [110] directions, and from -30° to 90° along the [111] direction. Due to the cubic symmetry of Diamond structure, these angular ranges ensure that the structure is non-repeating and is comprehensively analyzed in all three directions. Additionally, experimental tests were performed to validate the feasibility of the non-experimental methods. Results: It was shown from the experimental validation that the results from non-experimental methods were acceptable at certain porosities and orientations. The FE method, which is commonly used and a reliable approach, was utilized to represent the non-experimental methods and was compared with the experimental results. Therefore, the approximate analytical solutions and the results from elasticity theory were indirectly compared with experimental results. When the porosity of the structure was 85%, the approximate analytical solution showed differences of 17.65% relative to the FE result and 39.13% relative to the elasticity theory result. Therefore, the approximate analytical solution was considered acceptable at a higher porosity. The acceptable ranges of the porosity for applying the approximate analytical approach were higher than 85% in the [001] and [110] directions, and higher than 90% in the [111] direction. At the same structural porosity, in the (100) plane, the predicted results were acceptable when the structural orientation was close to 0° or 90°. In the (110) plane, the predicted results were acceptable when the structural orientation was close to 0°. In the (111) plane, whether the predicted results can be accepted or not was basically independent of the structural orientation but was dependent on the porosity of the structure. The planes of (100), (110) and (111) are defined as the planes perpendicular to the directions of [100], [110] and [111], respectively. Discussion: Data in the present study provide valuable guidance on applying the approximate analytical approach to efficiently predict the mechanical properties of TPMS structures prior to performing formal calculations and experiments.

21 October 2024 in Frontiers in Nutrition
Verified
Journal Article
Open access
PDF file
NJNizhou Jiang
Nizhou Jiang
QWQuanxiang Wang
Quanxiang Wang
JJJian Jiang
Jian Jiang
LLLei Li
Lei Li
Background: Intervertebral disk degeneration (IVDD) is a complex degenerative skeletal condition, potentially influenced by micronutrients and serum metabolites in its etiology. However, the exact causal relationship between these factors and IVDD remains ambiguous.Methods: The research employed a Two-Sample Mendelian Randomization (2SMR) analysis to thoroughly evaluate the causal relationship between 15 micronutrients (consisting of 7 minerals and 8 vitamins) as exposure variables, 1,091 blood metabolites, and 309 metabolite ratios as intermediary factors, and IVDD as the outcome. Additionally, reverse MR analysis and mediation analysis were carried out to validate the reliability of the results and explore the underlying mechanism by which micronutrients influence the risk of IVDD by regulating metabolites.Results: Among the micronutrients examined, vitamin B12 exhibited a noteworthy negative correlation with the incidence of IVDD (OR: 0.752, 95% [CI]: 0.573–0.987, p = 0.040), indicating a potential reduction in IVDD risk with increased vitamin B12 consumption. Of the 1,091 blood metabolites and 309 metabolite ratios analyzed, 52 metabolites displayed significant associations with IVDD, primarily linked to amino acid, fatty acid, nucleotide, and sphingolipid metabolic pathways. Mediation analysis identified 4-acetaminophen sulfate as a potential mediator in the protective effect of vitamin B12 against IVDD.Conclusion: This study has shown that vitamin B12 may reduce the risk of IVDD and has identified 52 serum metabolites that are associated with IVDD. Furthermore, it proposes that 4-acetaminophen sulfate could serve as a potential mechanism by which vitamin B12 exerts its inhibitory effects on IVDD.