Uterus measurements are useful for assessing both the treatment and follow-ups of gynaecological patients. The aim of our study was to develop a deep learning (DL) tool for fully automated measurement of the three-dimensional size of the uterus on magnetic resonance imaging (MRI). In this single-centre retrospective study, 900 cases were included to train, validate, and test a VGG-16/VGG-11 convolutional neural network (CNN). The ground truth was manual measurement. The performance of the model was evaluated using the objective key point similarity (OKS), the mean difference in millimetres, and coefficient of determination R2. The OKS of our model was 0.92 (validation) and 0.96 (test). The average deviation and R2 coefficient between the AI measurements and the manual ones were, respectively, 3.9 mm and 0.93 for two-point length, 3.7 mm and 0.94 for three-point length, 2.6 mm and 0.93 for width, 4.2 mm and 0.75 for thickness. The inter-radiologist variability was 1.4 mm. A three-dimensional automated measurement was obtained in 1.6 s. In conclusion, our model was able to locate the uterus on MRIs and place measurement points on it to obtain its three-dimensional measurement with a very good correlation compared to manual measurements.
Background The aim of our study was to develop, validate, and test a deep learning (DL) tool for fully automated measurement of the three-dimensional size of the uterus on magnetic resonance imaging (MRI) and to compare it to manual reference measurement. Materials and Methods In this single-centre retrospective study, 845 cases were included for training and validation. The ground truth was a manual measurement of the uterus on magnetic resonance (MR) images. A deep learning tool using a convolutional neural network (CNN) with VGG-16/VGG-11 architecture was developed. The performance of the model was evaluated using the objective keypoint similarity (OKS), mean difference in millimetres, and coefficient of determination R² on a new set of 100 patients. Results The OKS of our artificial intelligence (AI) model was 0.92 (validation) and 0.96 (test). These performances show a strong correspondence of the positioning of the measurement points between the algorithm and radiologists. The average deviation and R² coefficient between the AI measurements and the manual ones were respectively 3.9 mm and 0.93 for two-points length, 3.7 mm and 0.94 for three-points length, 2.6 mm and 0.93 for width, 4.2 mm and 0.75 for thickness. Inter-radiologist variability was 1.4 mm. A three-dimensional automated measurement was obtained in 1.6 s. Conclusion Our deep learning model can locate the uterus on MR images and place measurement points on it to obtain its three-dimensional measurement with a very good correlation with manual measurements.