Wind power has great uncertainty and short-term wind power forecasting technology can provide great help to power system scheduling after wind power integration. In this paper, a Convolutional neural network -bidirectional long and short-term memory network combination modeliCNN-BiLITMjbased on feature selection is proposed. Firstly, high correlation feature parameters were optimized based on effective feature screening of multidimensional feature datasets. Secondly, the input data are weighted according to the feature correlation to form a multi-dimensional feature data set. Finally, CNN-BiLSTM developed the wind energy forecast model. For verification, the KDD Cup 2022 wind power generation prediction data set was employed. The outcomes demonstrate that CNN-BiLSTM has a greater time series data utilization rate and prediction accuracy.
With the advancement of power systems, the integration of a substantial portion of renewable energy often leads to frequent voltage surges and increased fluctuations in distribution networks (DNs), significantly affecting the safety of DNs. Active distribution networks (ADNs) can address voltage issues arising from a high proportion of renewable energy by regulating distributed controllable resources. However, the conventional mathematical optimization-based approach to voltage reactive power control has certain limitations. It heavily depends on precise DN parameters, and its online implementation requires iterative solutions, resulting in prolonged computation time. In this study, we propose a Volt-VAR control (VVC) framework in ADNs based on multi-agent reinforcement learning (MARL). To simplify the control of photovoltaic (PV) inverters, the ADNs are initially divided into several distributed autonomous sub-networks based on the electrical distance of reactive voltage sensitivity. Subsequently, the Multi-Agent Soft Actor-Critic (MASAC) algorithm is employed to address the partitioned cooperative voltage control problem. During online deployment, the agents execute distributed cooperative control based on local observations. Comparative tests involving various methods are conducted on IEEE 33-bus and IEEE 141-bus medium-voltage DNs. The results demonstrate the effectiveness and versatility of this method in managing voltage fluctuations and mitigating reactive power loss.
In this paper, a big data visualization platform is designed to discover the hidden useful knowledge for smart grid (SG) operation, control and situation awareness. The spawn of smart sensors at both grid side and customer side can provide large volume of heterogeneous data that collect information in all time spectrums. Extracting useful knowledge from this big-data poll is still challenging. In this paper, the Apache Spark, an open source cluster computing framework, is used to process the big-data to effectively discover the hidden knowledge. A high-speed communication architecture utilizing the Open System Interconnection (OSI) model is designed to transmit the data to a visualization platform. This visualization platform uses Google Earth, a global geographic information system (GIS) to link the geological information with the SG knowledge and visualize the information in user defined fashion. The University of Denver's campus grid is used as a SG test bench and several demonstrations are presented for the proposed platform.
28 September 2022 in IEEE Journal of Radio Frequency Identification
With the promotion of energy security strategy and the access of the high penetration of renewable energy, the related methods of situational awareness in the traditional transmission network may be inapplicable for modern power grids. For the early warning and location of the cascading faults caused by power flow shift, a novel method for security situation prediction in the transmission network is put forward based on Long Short Term Memory. Firstly, the power flow model is used to construct the early warning framework of transmission network security situation based on LSTM, and ADASYN oversampling is used for sample equilibrium. Secondly, the validity of the proposed method is verified by the open-source platform “Grid2Op” in the modified IEEE 36-bus system. Results indicate that the early warning accuracy for cascading failure can achieve around 90% with prediction time less than 1 second. Various simulation results demonstrate that the proposed method can improve the accuracy of security situation warning, shorten the time for identifying abnormality of the transmission network and provide reliable support for the operation and maintenance of the transmission network.