This study highlights the importance of having a high clinical suspicion of hypercoagulopathy such as antiphospholipid syndrome (APS) in podiatric patients with normal foot pulses and normal standard coagulation tests. APS is an autoimmune disease that is characterized by inflammatory thrombosis in the arteries and veins and obstetric complications such as pregnancy loss. APS usually affects vessels of the lower extremities. We report herein the case of a 46-year-old woman with previous episodes of pre-eclampsia who suffered from partial ischemic necrosis of the hallux of the left foot. After several ischemic episodes of the hallux, with increased risk of toe amputation, the patient was finally diagnosed with APS and treated with specific anticoagulant medication. The patient’s symptoms subsided, and toe amputation was prevented. Early accurate diagnosis and appropriate clinical management are critical to providing optimal outcomes and reducing the risk of amputation.
Iatrogenic burns are unpleasant and sometimes difficult to explain to patients. Podiatric surgeons routinely use electrosurgical devices to cut and coagulate tissue during surgical procedures. Although advances in technology have made electrosurgery increasingly safer for patients and personnel, its use is still poorly understood by the surgical community, and the hazards associated with its use still exist presently. Human error, direct or indirect transfer of electricity to a conductive device, or device malfunction can cause serious adverse events, including burns, electrical shocks, and or fires. Here, we report a rare case of a 43-year-old man who suffered severe burns during hallux valgus surgery. The surgeon and the nursing staff did not notice any injuries during the surgical intervention. This unusual clinical case serves to highlight the importance of implementing protocols to prevent injuries related to the use of electrosurgery. Based on this report, a specific checklist was implemented to prevent adverse events related to electrosurgery in our podiatric surgery unit to reduce the risk of electrosurgical complications. The implementation of the checklist can be useful to help health professionals improve patient safety during surgery and avoid potential medico–legal liability claims.
Lobular capillary hemangioma (LCH-PG) is a type of pyogenic granuloma characterized by proliferating blood vessels that resemble conventional granulation tissue. Granulation tissue is very often seen in association with ingrown toenails. Despite the close relationship between both entities, LCH-PG shows clinically different behaviors, such as rapid growth and frequent recurrence. Currently, it is unknown exactly how the different etiological factors contribute to the formation of differences between entities. We present a case of a large LCH-PG associated with chronic onychocryptosis in a 26-year-old man. Histopathological features included extensive signs of ulceration, hyperkeratosis, and patchy epidermal acanthosis with the presence of fibrous septa with lobular areas beneath the ulcerative area. The presence of stroma with a marked proliferation of blood vessels with wall thickening and mixed-type inflammatory changes was also characteristic. In advanced stages of onychocryptosis, as presented here, conventional granulation tissue or pyogenic granuloma can be clinically difficult to distinguish from other benign or malignant neoplasms. Histological examination is mandatory, and excisional biopsy can provide a definitive diagnosis.
The plantar plate (PP) tear of the second metatarsophalangeal joint (MTPJ) is the most common reason for forefoot pain in clinical practice. PP is the main stabilizing structure of the joint and, together with collateral ligaments, is the key to maintaining the stability of MTPJ. Many surgical procedures have been described to repair PP tears. Currently, there is still controversy regarding which is the surgical superior option (direct versus indirect PP repair techniques). Transfer of the flexor digitorum longus tendon to the dorsum of the proximal phalanx is one of the surgical techniques described to treat PP tears associated with MTPJ instability. We present two cases that developed instability of the second MTPJ secondary to chronic PP tear with symptoms resolved after transfer of the flexor digitorum longus (FDL). Currently, the literature review shows that the procedure seems to be the most consistent surgical option in chronic cases of PP tears.
Podiatric surgeons routinely use electrosurgical devices to cut and coagulate tissue during surgical procedures. Although advances in technology have made electrosurgery increasingly safer for patients and personnel, its use is still poorly understood by those using it and the hazards associated with its use still exist presently. Human error, direct or indirect transfer of electricity to a conductive device, or device malfunction can cause serious adverse events, including burns, electrical shocks, and or fires. Here, we report a rare case of a 43-year-old man who suffered severe burns during hallux valgus surgery. The surgeon and the nursing staff did not notice any injuries during the surgical intervention. This case highlights the need to implement tools to help health professionals improve patient safety during surgery. Based on the case herein reported, a specific checklist was implemented to prevent adverse events related to electrosurgery in our podiatric unit to reduce the risk of electrosurgical complications.
Background and Clinical Significance: The plantar plate (PP) tear of the second metatarsophalangeal joint (MTPJ) is a common cause of forefoot pain in clinical practice. The PP is the main stabilizing structure of the joint and, together with the collateral ligaments, is the key to maintaining the stability of the MTPJ. Many surgical procedures have been described to repair PP tears. Currently, there is still controversy regarding which is the surgical superior option (direct versus indirect PP repair techniques). Transfer of the flexor digitorum longus tendon to the dorsum of the proximal phalanx is one of the surgical techniques described to treat PP tears associated with MTPJ instability. Case Presentation: We present two cases that developed instability of the second MTPJ secondary to chronic PP tear with symptoms resolved after transfer of the flexor digitorum longus (FDL). Conclusions: Currently, the literature review shows that the procedure seems to be the most consistent surgical option in chronic cases of PP tears.