Qing Ye

Dr. Qing Ye


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2023 in International Journal of Bioprinting
Verified
Journal Article
Open access
PDF file
MZMingshan Zhang
Mingshan Zhang
FYFang Yang
Fang Yang
DHDaobo Han
Daobo Han
SZShi-Yao Zhang
Shi-Yao Zhang
YDYipeng Dong
Yipeng Dong
YWYan Wang
Yan Wang
Millions of individuals across the world suffer from corneal stromal diseases that impair vision. Fortunately, three-dimensional (3D) bioprinting technology which has revolutionized the field of regenerative tissue engineering makes it feasible to create personalized corneas. In this study, an artificial cornea with a high degree of precision, smoothness, and programmable curvature was prepared by using digital light processing (DLP) 3D bioprinting in one piece with no support structure, and the construct was then confirmed by optical coherence tomography (OCT). On the basis of this approach, we developed a novel corneal decellularized extracellular matrix/gelatin methacryloyl (CECM-GelMA) bioink that can produce complex microenvironments with highly tunable mechanical properties while retaining high optical transmittance. Furthermore, the composite hydrogel was loaded with human corneal fibroblasts (hCFs), and in vitro experiments showed that the hydrogel maintained high cell viability and expressed core proteins. In vivo tests revealed that the hydrogel might promote epithelial regeneration, keep the matrix aligned, and restore clarity. This demonstrates how crucial a role CECM plays in establishing a favorable environment that encourages the transformation of cell function. Therefore, artificial corneas that can be rapidly customized have a huge potential in the development of in vitro corneal matrix analogs.

7 March 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
SLShike Liu
Shike Liu
ZDZhichao Deng
Zhichao Deng
JLJianwei Li
Jianwei Li
JWJin Wang
Jin Wang
NHNingning Huang
Ningning Huang
JTJianguo Tian
Jianguo Tian
It is known that the study of optical properties of biological tissue contains much information that plays an important role in medical diagnostics and therapy.1 – 7 The optical properties of blood are required for a number of methods, such as optical coherent tomography,8 transmission electron microscopy,9 and derivative total internal reflection method,10 to calculate the distribution in the sample. As an important optical parameter, the refractive index of blood sample, which reflects the physiological state and functions regularity, appears crucial in many fields. Blood analysis, which depends on the measurement of refractive index, is widely used as a diagnostic basis for clinical application. Blood plasma and serum are the most substantial biochemical samples in clinical examination, and the substantial difference between them is whether it contains fibrinogen or not.11 For example, Li et al.12 determined the refractive index of different types of human blood sample based on the total internal reflection, and the measurements have an important reference value in pathology and medical laboratory sciences. Mazarevica et al.13 reported a qualitative relationship that the values of the refractive indices of red blood cells (RBCs) significantly decrease for the diabetic patients compared with healthy donors at the same pH level, and Maximov et al.14 confirmed this a few years later. Park et al.15 determined that the refractive index of RBCs declined due to the volume of cytoplasm reduced during infection and used it as an important indicator to diagnose malaria. The refractive index of RBCs can also be seen as a parameter for diagnosis of anemia.16

1 January 2011 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
QYQing Ye
Qing Ye
JWJin Wang
Jin Wang
ZDZhi-Chao Deng
Zhi-Chao Deng
WZWen-Yuan Zhou
Wen-Yuan Zhou
CZChun-Ping Zhang
Chun-Ping Zhang
JTJian-Guo Tian
Jian-Guo Tian
Refractive index of biotissue is a useful optical parameter in the biomedical field. An extended differential total reflection method is introduced to determine the complex refractive index. The real part is directly determined by differential of the reflectance curve, and the imaginary part is obtained from nonlinear fitting. The method is verified by a series of tissue-mimicking phantoms, porcine muscle and porcine adipose.

8 April 2022 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
YDYipeng Dong
Yipeng Dong
MZMingshan Zhang
Mingshan Zhang
DHDaobo Han
Daobo Han
ZDZhichao Deng
Zhichao Deng
XCXuewei Cao
Xuewei Cao
QYQing Ye
Qing Ye
A GelMA–GelMA (G–G) homogeneous double-network hydrogel was constructed assisted by DLP 3D printing to obtain excellent performance especially mechanical properties.

1 January 2016 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
ZDZhichao Deng
Zhichao Deng
JWJin Wang
Jin Wang
QYQing Ye
Qing Ye
TSTengqian Sun
Tengqian Sun
WZWenyuan Zhou
Wenyuan Zhou
JTJian-Guo Tian
Jian-Guo Tian
The complex refractive index dispersion (CRID), which contains the information on the refractive index dispersion and extinction coefficient spectra, is an important optical parameter of biotissue. However, it is hard to perform the CRID measurement on biotissues due to their high scattering property. Continuous CRID measurement based on internal reflection (CCRIDM-IR) is introduced. By using a lab-made apparatus, internal reflectance spectra of biotissue samples at multiple incident angles were detected, from which the continuous CRIDs were calculated based on the Fresnel formula. Results showed that in 400- to 750-nm range, hemoglobin solution has complicated dispersion and extinction coefficient spectra, while other biotissues have normal dispersion properties, and their extinction coefficients do not vary much with different wavelengths. The normal dispersion can be accurately described by several coefficients of dispersion equations (Cauchy equation, Cornu equation, and Conrady equation). To our knowledge, this is the first time that the continuous CRID of scattering biotissue over a continuous spectral region is measured, and we hereby have proven that CCRIDM-IR is a good method for continuous CRID research of biotissue.

28 March 2024 in Biofabrication
Verified
Journal Article
Open access
PDF file
SZShi-Yao Zhang
Shi-Yao Zhang
MZMingshan Zhang
Mingshan Zhang
XLXin-Yu Li
Xin-Yu Li
SHShuai Huang
Shuai Huang
DHDaobo Han
Daobo Han
YWYan Wang
Yan Wang
Corneal damage contributes to blindness in millions of people. Simulating natural corneas with artificial corneas is challenging due to material and manufacturing limitations, including poor mechanical properties, complex manufacturing processes, and ocular histocompatibility. In this study, electrospun micro-nanofibrous decellularized extracellular matrix (dECM) is combined with digital light processing 3D bioprinting and validated as a bioartificial cornea for the first time. Electrospinning gives the material a controllable shape, and the electrospun micro-nanofibrous dECM, with preserved inherent biochemical components, can better mimic the natural ECM native microenvironment. An efficient platform can be developed for creating novel structural materials, when combined with intelligent manufacturing. Artificial biological corneas developed using this method showed five-fold improvements in mechanical properties (248.5 ± 35.67 kPa vs. 56.91 ± 3.68 kPa, p < 0.001), superior guidance for cell organization and adhesion, and better maintenance of the cellular phenotype of keratocytes. In animal studies, in vivo transplantation of this artificial cornea showed better regeneration, which accelerated corneal epithelialization and maintained corneal transparency. This method has potential for biomedical applications, and bioartificial corneas manufactured by this method have ideal properties as an alternative to lamellar keratoplasty, with promise for clinical transformation.