Membrane cofactor protein (MCP; CD46) is a widely expressed transmembrane complement regulator. Like factor H it inhibits complement activation by regulating C3b deposition on targets. Factor H mutations occur in 10–20% of patients with hemolytic uremic syndrome (HUS). We hypothesized that MCP mutations could predispose to HUS, and we sequenced MCP coding exons in affected individuals from 30 families. MCP mutations were detected in affected individuals of three families: a deletion of two amino acids (D237/S238) in family 1 (heterozygous) and a substitution, S206P, in families 2 (heterozygous) and 3 (homozygous). We evaluated protein expression and function in peripheral blood mononuclear cells from these individuals. An individual with the D237/S238 deletion had reduced MCP levels and ≈50% C3b binding compared with normal controls. Individuals with the S206P change expressed normal quantities of protein, but demonstrated ≈50% reduction in C3b binding in heterozygotes and complete lack of C3b binding in homozygotes. MCP expression and function was evaluated in transfectants reproducing these mutations. The deletion mutant was retained intracellularly. S206P protein was expressed on the cell surface but had a reduced ability to prevent complement activation, consistent with its reduced C3b binding and cofactor activity. This study presents further evidence that complement dysregulation predisposes to development of thrombotic microangiopathy and that screening patients for such defects could provide informed treatment strategies.
Accurate measurement of GFR is critical for the evaluation of new therapies and the care of renal transplant recipients. Although not accurate in renal transplantation, GFR is often estimated using creatinine-based equations. Cystatin C is a marker of GFR that seems to be more accurate than creatinine. Equations to predict GFR based on the serum cystatin C concentration have been developed, but their accuracy in transplantation is unknown. GFR was estimated using four equations (Filler, Le Bricon, Larsson, and Hoek) that are based on serum cystatin C and seven equations that are based on serum creatinine in 117 adult renal transplant recipients. GFR was measured using radiolabeled diethylenetriaminepentaacetic acid (99mTc-DTPA), and the bias, precision, and accuracy of each equation were determined. The mean 99mTc-DTPA GFR was 58 ± 23 ml/min per 1.73 m2. The cystatin C–based equations of Filler and Le Bricon had the lowest bias (−1.7 and −3.8 ml/min per 1.73 m2), greatest precision (11.4 and 11.8 ml/min per 1.73 m2), and highest accuracy (87 and 89% within 30% of measured GFR, respectively). The cystatin C equations remained accurate even when the measured GFR was >60 ml/min per 1.73 m2. The creatinine-based equations were not as accurate, with only 53 to 80% of estimates within 30% of measured GFR. Cystatin C–based equations are more accurate at predicting GFR in renal transplant recipients than traditional creatinine-based equations. Further prospective studies with repetitive measurement of cystatin C are needed to determine whether cystatin C–based estimates of GFR will be sufficiently accurate to monitor long-term allograft function.