sivasankar venkataraman

Dr. sivasankar venkataraman


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Science of The Total Environment
Verified
Journal Article
Closed access
TST.G. Sunitha
T.G. Sunitha
VMV. Monisha
V. Monisha
SSS. Sivanesan
S. Sivanesan
MVM. Vasanthy
M. Vasanthy
MPM. Prabhakaran
M. Prabhakaran
ADA. Darchen
A. Darchen

1 May 2010 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
SVsivasankar venkataraman
sivasankar venkataraman
TRT. Ramachandramoorthy
T. Ramachandramoorthy
ACA. Chandramohan
A. Chandramohan

1 October 2020 in Environmental Pollution
Verified
Journal Article
Closed access
BVBongekile Vilakati
Bongekile Vilakati
SVsivasankar venkataraman
sivasankar venkataraman
BMBhekie B. Mamba
Bhekie B. Mamba
KOKiyoshi Omine
Kiyoshi Omine
TMTitus Msagati
Titus Msagati

21 February 2022 in Ecotoxicology and Environmental Safety
Verified
Journal Article
Open access
SCS.D. Chicas
S.D. Chicas
KOKiyoshi Omine
Kiyoshi Omine
MPM. Prabhakaran
M. Prabhakaran
TST.G. Sunitha
T.G. Sunitha
SVsivasankar venkataraman
sivasankar venkataraman
The present investigation in the Tiruvannamalai region is about high fluoride contamination of groundwater samples from bore wells and open wells. About 75% of groundwater samples were found predominantly containing the fluoride content greater than the acceptable limit of 1.5 mg/L in the ranges 1.51 - 2.00 mg/L (23%), 2.01 - 3.00 mg/L (36%) and greater than or equal to 3.01 mg/L (16%) as per WHO. The other water quality parameters were found within the permissible limit of WHO. Taking the groundwater sources into consideration, the non - carcinogenic risk due to high fluoride concentration in groundwater sources revealed that teen - aged (98%), Children (92%) and Infant (98%) categories were at greater risk than those under Men (50%) and Women (69%) categories. The mapping was done on the spatial distribution of fluoride concentration in groundwater and the associated health risk by Ordinary Kriging. The correlation coefficients among the parameters witnessed that the hydro-chemical facies are interdependent. Box - Whisker plots illustrated the dispersion of various water quality parameters. The WQI data represented the quality of groundwater in view of potable nature due to dissolved ions. The Gibbs, bivariate mixing and the scatter plots ascribed the dissolution of carbonate and silicate minerals which dominate the groundwater chemistry. The factor analysis detailed the extracted loadings of different parameters of groundwater sources and differentiated the percentage variance values between bore well and open well sources.

1 October 2021 in Ecotoxicology and Environmental Safety
Verified
Journal Article
Open access
BVBongekile Vilakati
Bongekile Vilakati
SVsivasankar venkataraman
sivasankar venkataraman
HNHlengilizwe Nyoni
Hlengilizwe Nyoni
BMBhekie B. Mamba
Bhekie B. Mamba
KOKiyoshi Omine
Kiyoshi Omine
TMTitus Msagati
Titus Msagati
Wastewater treatment plants (WWTPs) in South Africa, like is the case for most WWTPs around the globe albeit capable of removing substantial quantities of microplastics (MPs) and in fact, the treatments become ineffective for those plastic particles less than 100 µm. As a consequence, the receiving water bodies in which the final effluent is discharged becomes highly polluted. The present research is devoted to the analysis of the pervasive MPs in wastewaters of the treatment plant located in the Gauteng Province, South Africa using Pyrolysis - GC-TOF-MS. Based on the results, there were 23 pyrolyzate products with contributions from PVC, PA, PET and PE with abundances of 47.8%, 13.1%, 17.4% and 4.3% respectively. The remaining 17.4% could be attributed as additives in MPs. The SEM images illustrated that the MPs appeared to be inter - wined, fibrous of different thicknesses and lengths. The highly weathered MPs exhibited the rough surface which was noticeably damaged with peeled off layers presumably because of photo-oxidation during the aging process. The vibrational modes of FTIR revealed the presence of the various functional groups in the corresponding polymers of MPs. The thermal studies confirmed the presence of calcium, aluminum and silicon as residues of catalysts or flame retardants or UV stabilizers in MPs or as adsorbates resulting from the surface adsorption from the surroundings. The Py-GC-TOF-MS confirmed the identity of the various fragments related to the MPs monomers.

20 August 2016
Verified
Book Chapter
Closed access
PDF file
SVsivasankar venkataraman
sivasankar venkataraman
ADAndré Darchen
André Darchen
KOKiyoshi Omine
Kiyoshi Omine
RSR. Sakthivel
R. Sakthivel