Matthew David Laffey

Mr. Matthew David Laffey

Trinity College Dublin, Dublin, Ireland
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2024 in Journal of Anesthesia, Analgesia and Critical Care
Verified
Journal Article
Open access
PDF file
ANAlice Nova
Alice Nova
BMBairbre McNicholas
Bairbre McNicholas
AMAurora Magliocca
Aurora Magliocca
MLMatthew David Laffey
Matthew David Laffey
VZVanessa Zambelli
Vanessa Zambelli
TGThe LUNG-KIDNEY Interaction Multicenter Study Group
The LUNG-KIDNEY Interaction Multicenter Study Group
Background: Lung perfusion defects, mainly due to endothelial and coagulation activation, are a key contributor to COVID-19 respiratory failure. COVID-19 patients may also develop acute kidney injury (AKI) because of renal perfusion deficit. We aimed to explore AKI-associated factors and the independent prediction of standardized minute ventilation (MV)—a proxy of alveolar dead space—on AKI onset and persistence in COVID-19 mechanically ventilated patients. Methods: This is a multicenter observational cohort study. We enrolled 157 COVID-19 patients requiring mechanical ventilation and intensive care unit (ICU) admission. We collected clinical information, ventilation, and laboratory data. AKI was defined by the 2012 KDIGO guidelines and classified as transient or persistent according to serum creatinine criteria persistence within 48 h. Ordered univariate and multivariate logistic regression analyses were employed to identify variables associated with AKI onset and persistence. Results: Among 157 COVID-19 patients on mechanical ventilation, 47% developed AKI: 10% had transient AKI, and 37% had persistent AKI. The degree of hypoxia was not associated with differences in AKI severity. Across increasing severity of AKI groups, despite similar levels of paCO2, we observed an increased MV and standardized MV, a robust proxy of alveolar dead space. After adjusting for other clinical and laboratory covariates, standardized MV remained an independent predictor of AKI development and persistence. d-dimer levels were higher in patients with persistent AKI. Conclusions: In critically ill COVID-19 patients with respiratory failure, increased wasted ventilation is independently associated with a greater risk of persistent AKI. These hypothesis-generating findings may suggest that perfusion derangements may link the pathophysiology of both wasted ventilation and acute kidney injury in our population.

1 September 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MLMatthew David Laffey
Matthew David Laffey
BTBrooke Tornifoglio
Brooke Tornifoglio
CLCaitriona Lally
Caitriona Lally
Aortic aneurysms (AA) occur in 4.8% of people causing 150,000 deaths annually. While endovascular aneurysm repairs reduce surgical morbidity, device-related failures (leak/displacement) are frequent highlighting the need for test models that better represent the mural geometry and compliance changes in human AAs. We aimed to develop and characterise an ex vivo porcine aortic model of AA. The optimal duration of tissue elastase exposure to emulate AA changes in elastin microstructure and content was determined using porcine aortic rings. Elastase-induced changes were quantified morphologically, and mechanical properties assessed via ring tensile testing. Subsequent experiments tested the potential for localised elastase treatment in a 1 cm segment of porcine aorta using a specially designed 3D printed rig. The effect on pressure-diameter behaviour was investigated via inflation-extension testing. Elastase treatment produced time dependent decreases in elastin, resulting in an increased tensile modulus and circumferential length in the ring samples in the final phase of the J-shaped tissue stress-strain curves. In whole aortic segments, localised elastase-induced luminal degradation was successfully limited to a central region. The degree of elastin degradation achieved was sufficient to cause localised dilation with respect to controls under physiological pressures. Localised elastin degradation in porcine aortic segments is feasible and emulates the changes seen clinically in aortic aneurysms.

28 July 2005
Verified
Conference Paper
Closed access
PMP. Morganelli
P. Morganelli
JSJ. Shah
J. Shah
BWB. Wheelock
B. Wheelock
VMV. Mohan
V. Mohan
MLMatthew David Laffey
Matthew David Laffey
A novel pre-applied underfill is presented. In this approach, a B-staged thermoset is applied to a chip-scale package (CSP) as a thin layer over the solder bump array. During reflow, the coating expands to fill the standoff gap between the PCB and package, providing reinforcement to the solder joints. The underfill material is stable at typical drying and burn-in conditions, allowing it to be applied early in the manufacturing process. The expanded underfill was found to improve drop impact resistance significantly relative to a non-underfilled CSP.

19 July 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
MLMatthew David Laffey
Matthew David Laffey
BTBrooke Tornifoglio
Brooke Tornifoglio
CLCaitriona Lally
Caitriona Lally
Aortic aneurysms (AA) occur in 4.8% of people causing 150,000 deaths annually. While endovascular aneurysm repairs reduce surgical morbidity, device-related failures (leak/displacement) are frequent highlighting the need for test models that better represent the mural geometry and compliance changes in human AAs. We aimed to develop and characterise an ex vivo porcine aortic model of AA. The optimal duration of tissue elastase exposure to emulate AA changes in elastin microstructure and content was determined using porcine aortic rings. Elastase-induced changes were quantified morphologically, and mechanical properties assessed via ring tensile testing. Subsequent experiments tested the potential for localised elastase treatment in a 1 cm segment of porcine aorta using a specially designed 3D printed test rig. The effect on pressure-diameter behaviour was investigated via inflation-extension testing. Elastase treatment produced time dependent decreases in elastin, resulting in an increased tensile modulus and circumferential length in the ring samples in the final phase of the J-shaped tissue stress-strain curves. In whole aortic segments, localised elastase-induced luminal degradation was successfully limited to a central region. The degree of elastin degradation achieved was sufficient to cause localised dilation with respect to controls under physiological pressures. Localised elastin degradation in porcine aortic segments is feasible and emulates the changes seen clinically in aortic aneurysms.

20 October 2026 in Irish Journal of Medical Science (1971 -)
Verified
Journal Article
Closed access
PDF file
MLMatthew David Laffey
Matthew David Laffey
FOFergus O’HErlihy
Fergus O’HErlihy
CFCormac Farrelly
Cormac Farrelly