Morphy Dumlao

Dr. Morphy Dumlao

School of Science, University of New South Wales, Canberra, Australian Capital Territory, Australia
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2004 in Forensic Science International
Verified
Journal Article
Closed access
FDFabian Dayrit
Fabian Dayrit
MDMorphy Dumlao
Morphy Dumlao

14 March 2016 in The Analyst
Verified
Journal Article
Open access
PDF file
MDMorphy Dumlao
Morphy Dumlao
LJLaura E. Jeffress
Laura E. Jeffress
J. GoodingJ. Gooding
J. Gooding
WDWilliam Alexander Donald
William Alexander Donald
Solid-phase microextraction (SPME) is directly integrated with low temperature plasma ionisation mass spectrometry to rapidly detect organophosphate chemical warfare agent simulants and their hydrolysis products in chemical mixtures, including urine. In this sampling and ionization method, the fibre serves: (i) to extract molecules from their native environment, and (ii) as the ionization electrode that is used to desorb and ionize molecules directly from the SPME surface. By use of a custom fabricated SPME fibre consisting of a stainless steel needle coated with a Linde Type A (LTA) zeolitic microporous material and low temperature plasma mass spectrometry, protonated dimethyl methylphosphonate (DMMP), diethyl ethylphosphonate (DEEP) and pinacolyl methylphosphonic acid (PinMPA) can be detected at less than 100 ppb directly in water and urine. Organophosphates were not readily detected by this approach using an uncoated needle in negative control experiments. The use of the LTA coating significantly outperformed the use of a high alumina Zeolite Socony Mobil-5 (ZSM-5) coating of comparable thickness that is significantly less polar than LTA. By conditioning the LTA probe by immersion in an aqueous CuSO4 solution, the ion abundance for protonated DMMP increased by more than 300% compared to that obtained without any conditioning. Sample recovery values were between 96 and 100% for each analyte. The detection of chemical warfare agent analogues and hydrolysis products required less than 2 min per sample. A key advantage of this sampling and ionization method is that analyte ions can be directly and rapidly sampled from chemical mixtures, such as urine and seawater, without sample preparation or chromatography for sensitive detection by mass spectrometry. This ion source should prove beneficial for portable mass spectrometry applications because relatively low detection limits can be obtained without the use of compressed gases, fluid pumps, and lasers. Moreover, the ion source is compact, can be powered with a 10 V battery, and is tolerant of complex mixtures.

5 October 2015 in Journal of the American Society for Mass Spectrometry
Verified
Journal Article
Closed access
PDF file
ESEdward R. Stephens
Edward R. Stephens
MDMorphy Dumlao
Morphy Dumlao
DXDan Xiao
Dan Xiao
DZDaming Zhang
Daming Zhang
WDWilliam Alexander Donald
William Alexander Donald

12 September 2017 in Australian Journal of Chemistry
Verified
Journal Article
Open access
PDF file
MDMorphy Dumlao
Morphy Dumlao
GKGeorge N. Khairallah
George N. Khairallah
WDWilliam Alexander Donald
William Alexander Donald
The extent of internal energy deposition using three different plasma-based ionization mass spectrometry (MS) methods, atmospheric pressure chemical ionization (APCI), direct analysis in real time (DART), and active capillary dielectric barrier discharge ionization (DBDI), was investigated using benzylammonium ‘thermometer’ ions. Ions formed by DBDI were activated significantly less than those that were formed by DART and APCI under these conditions. Thermal ion activation by DART can be reduced slightly by positioning the DART source further from the capillary entrance to the MS and reducing the heat that is applied to metastable atoms exiting the DART source. For example, the average ion internal energy distribution decreased by less than 10 % (166.9 ± 0.3 to 152.2 ± 1.0 kJ mol-1) when the distance between the DART source and the MS was increased by 250 % (10 to 25 mm). By lowering the DART temperature from 350 to 150°C, the internal energy distributions of the thermometer ions decreased by ~15 % (169.93 ± 0.83 to 150.21 ± 0.52 kJ mol-1). Positioning the DART source nozzle more than 25 mm from the entrance to the MS and decreasing the DART temperature further resulted in a significant decrease in ion signal. Thus, varying the major DART ion source parameters had minimal impact on the ‘softness’ of the DART ion source under these conditions. Overall, these data indicate that DBDI can be a significantly ‘softer’ ion source than two of the most widely used plasma-based ion sources that are commercially available.

21 February 2020 in Analytical Chemistry
Verified
Journal Article
Closed access
EAEzaz Ahmed
Ezaz Ahmed
DXDan Xiao
Dan Xiao
MDMorphy Dumlao
Morphy Dumlao
CSChristopher Charles Steel
Christopher Charles Steel
Leigh SchmidtkeLeigh Schmidtke
Leigh Schmidtke
WDWilliam Alexander Donald
William Alexander Donald

26 March 2014 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
MDMorphy Dumlao
Morphy Dumlao
PSPablo Sinues
Pablo Sinues
MNMaryia Nudnova
Maryia Nudnova
RZRenato Zenobi
Renato Zenobi
A novel analytical technique to detect chemical warfare agent (CWA) simulants in forensic samples is presented. Three G-agent type simulants that closely mimic real CWAs, namely dimethyl methylphosphonate (DMMP), diethyl ethylphosphonate (DEEP), and diethyl phosphoramidate (DEPA), and in addition a hydrolysis product, pinacolyl methylphosphonate (PMP), were utilized. Dilute solutions spotted onto six different forensic matrices were used to evaluate the capability of an active capillary plasma ionization source, which could be attached to the inlets of either a conventional benchtop ion trap mass spectrometer or a miniaturized ion trap mass spectrometer, under ambient conditions. The sample solutions and matrix surfaces were exposed for about 10–20 seconds at a distance of 1 cm from the plasma ion source inlet. This real-time methodology was found to have a shorter analysis time than previously reported techniques. A full method validation, quantitative studies, and optimization for detection of real CWAs on forensic matrices should be done in the future.