Zannat Kawser

Zannat Kawser


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2022 in International Journal of Applied & Basic Medical Research
Verified
Journal Article
Open access
ZKZannat Kawser
Zannat Kawser
SSS. M. Shamsuzzaman
S. M. Shamsuzzaman
Introduction: Infections caused by multidrug-resistant (MDR) hypervirulent Klebsiella pneumoniae are difficult to treat and associated with high mortality rates. Hence, this study was conducted to determine the antibiotic resistance pattern along with the distribution of virulence genes among isolated string test positive and negative strains. Materials and Methods: A total of 44 K. pneumoniae strains were isolated following standard microbiological methods from 350 different clinical samples from patients admitted to Dhaka Medical College Hospital, Bangladesh. String test was done to detect the hypermucoid phenotype. Antimicrobial resistance (AMR) pattern was determined by dichlorodiphenyltrichloroethane (except colistin and fosfomycin) among all isolates. Polymerase chain reaction was done to detect the hypervirulence genes (magA, rmpA, rmpA2 iutA, iroN). Results: In this study, 21/44 (47.73%) of the isolated K. pneumoniae were string test positive and distribution of the virulence genes except rmpA2 was higher among them. A total of 15/44 (34.09%) of the isolated K. pneumoniae were MDR, 10/44 (22.73%) were extensively drug resistant, 1/44 (2.27%) was pan drug resistant, and 14/44 (31.82%) were colistin resistant. Isolated organisms were highly resistant to third-generation cephalosporins and most sensitive to fosfomycin in this study. Although all the string test positive strains showed higher resistance rates than the string test negative ones toward most of the tested antibiotics, only the differences of resistance rates to amoxiclav and tigecycline among the two phenotypes were statistically significant. Conclusion: Our findings highlight the importance of surveillance of the AMR pattern of hypervirulent K. pneumoniae in clinical samples. Therefore, a response to check the global dissemination of this hypervirulent K. pneumoniae with resistance determinants is urgently needed.

15 August 2022 in The American Journal of Tropical Medicine and Hygiene
Verified
Journal Article
Open access
PDF file
ZKZannat Kawser
Zannat Kawser
MHMohabbat Hossain
Mohabbat Hossain
SSSARA SULIMAN
SARA SULIMAN
SLShahin Lockman
Shahin Lockman
JGJesse Gitaka
Jesse Gitaka
FQFirdausi Qadri
Firdausi Qadri
Early detection of SARS-CoV-2 infection is crucial to prevent its spread. This study aimed to document test sensitivity/specificity, correlation with cycle threshold value from polymerase chain reaction (PCR), fitness-for-use in different populations and settings, and user perspectives that could inform large-scale implementation. In this study, we evaluated the performance of a rapid antigen detection test, BD Veritor, and compared this (and another rapid test, Standard Q) against reverse transcription PCR (RT-PCR) in terms of sensitivity and specificity in 130 symptomatic and 130 asymptomatic adults. In addition, we evaluated the suitability and ease of use of the BD Veritor test in a subsample of study participants (n = 42) and implementers (n = 5). At 95% confidence interval, the sensitivity of the BD Veritor and Standard Q test were 70% and 63% in symptomatic and 87% and 73% in asymptomatic individuals, respectively, regarding positive SARS-CoV-2 RT-PCR results. Overall, the BD Veritor test was 78% sensitive and 99.5% specific compared with RT-PCR irrespective of the cycle threshold. This warrants large field evaluation as well as use of the rapid antigen test for quick assessment of SARS-CoV-2 for containment of epidemics in the country.

1 January 2021 in International Journal of Applied & Basic Medical Research
Verified
Journal Article
Open access
ZKZannat Kawser
Zannat Kawser
SSSm Shamsuzzaman
Sm Shamsuzzaman
To determine the protective efficacy of antibodies elicited by killed vaccine against multidrug-resistant (MDR) K. pneumoniae. Materials and Methods: In this study, heat-killed MDR K. pneumoniae isolated from different clinical samples were employed for the intradermal immunization of 10 BALB/c mice. Two weeks after the third dose of immunization, the mice were intraperitoneally challenged with live K. pneumoniae and observed for 14 days. Tail blood was collected 7 days after each booster followed by cardiac puncture 14 days postchallenge. Bactericidal activity and antigen-binding capacity of the serum antibody produced by the vaccine were evaluated by serum bactericidal antibody (SBA) assay and ELISA, respectively. Results: In this study, 80% survival rates were observed at 14 days postchallenge among the immunized mice. Regarding SBA assay, 100% bactericidal activity of the immunized mouse sera was observed using 50% guinea pig complement at 1:10 serum dilution after 3 h of incubation, and all the pre- and postchallenge immunized serum immunoglobulin G antibody had significantly higher optical density values comparing the control mice in ELISA. Conclusion: In our study, intradermal immunization with heat-killed MDR K. pneumoniae produced protective antibodies in BALB/c mice. These findings suggest that the use of a first-generation vaccine provides the supply of a larger number of candidate antigens for eliciting required immune response....

24 December 2024 in Journal of Global Antimicrobial Resistance
Verified
Journal Article
Open access
ZKZannat Kawser
Zannat Kawser
SSSushmita Sridhar
Sushmita Sridhar
SKSanchita Kar
Sanchita Kar
THTanbir Habib
Tanbir Habib
SMSharmin Akter Mukta
Sharmin Akter Mukta
RLRegina C LaRocque
Regina C LaRocque
Klebsiella pneumoniae (Kpn), a WHO priority pathogen with high rates of antimicrobial resistance (AMR), has emerged as a leading cause of hospital acquired pneumonia and neonatal sepsis. We aimed to define the clinical characteristics of a cohort of patients with Kpn infection in Dhaka, Bangladesh and to perform phenotypic and genetic characterization of the associated isolates. We retrospectively extracted clinical data about patients at Dhaka Medical College Hospital from whom Klebsiella spp was isolated from a clinical specimen collected between February and September 2022. We used standard microbiologic techniques to evaluate AMR and whole-genome sequencing (WGS) to assess dominant lineages, common capsular (K) and O-polysaccharide (O) antigen types, and AMR and virulence genes. Ninety-eight patients were included, with diagnoses of pneumonia (38/98, 39 %), wound infection (29/98, 31 %), urinary tract infection (29/98, 31 %) and bacteremia (2/98, 2 %). We tested isolates for susceptibility to eight classes of antibiotics. Of the 98 isolates, 41 % were multidrug resistant (MDR), 15 % were extensively drug resistant (XDR), and 16 % were pan-drug resistant (PDR). Three isolates (3 %) were resistant to polymyxin B. Outcome data were available for 46 patients; 4 patients (8 %) died from infections caused by PDR (n = 2), XDR (n = 1), and MDR isolates (n = 1). WGS revealed a high degree of genomic diversity, with multiple sequence types (STs), O-types and K-types represented; ST16:K81:OL101 and ST43:K30:O1 were the most prevalent. Our findings suggest alarming levels of AMR among Kpn isolates in Bangladesh and a critical need for improved treatment modalities and vaccine development.

7 October 2021 in medRxiv
Verified
Preprint
Open access
PDF file
ZKZannat Kawser
Zannat Kawser
MHMohabbat Hossain
Mohabbat Hossain
SSSARA SULIMAN
SARA SULIMAN
SLShahin Lockman
Shahin Lockman
JGJesse Gitaka
Jesse Gitaka
FQFirdausi Qadri
Firdausi Qadri
Early detection of SARS-CoV-2 infection is crucial to prevent the spread of the virus. In this study, we evaluated the performance of a commercial rapid antigen detection test, BD Veritor, and compared this (and another rapid test, Standard Q) against a gold-standard of nasopharyngeal (NP) swab tested by reverse transcription-polymerase chain reaction (RT-PCR) in prospectively-recruited adults in Dhaka, Bangladesh. We compared the sensitivity and specificity of the two rapid antigen tests against RT-PCR results in 130 symptomatic and 130 asymptomatic adults. In addition, we evaluated the suitability and ease-of-use of the BD Veritor test in a subsample of study participants (n=42) and implementers (n=5). The sensitivity of the BD Veritor rapid antigen test was 70% in symptomatic (95% confidence interval [CI]: 51-85%) and 87% (95% CI: 69-96%) in asymptomatic individuals with positive SARSCoV-2 RT-PCR, for overall sensitivity of 78% (95% CI: 66-88%). The sensitivity of the Standard Q rapid antigen test was 63% (95% CI: 44-80%) in symptomatic and 73% (95% CI: 54-87%) in asymptomatic individuals. One false positive in BD Veritor test (specificity 99.5) and no false positive in Standard Q tests were observed (specificity 100%). The BD Veritor rapid antigen test was 78% sensitive when compared with RT-PCR irrespective of the cycle threshold (Ct) levels in this evaluation in Bangladesh. The implementation evaluation data showed good acceptability in the field settings. This warrants large field evaluation as well as use of the rapid antigen test for quick assessment of SARS-CoV-2 for containment of epidemics in the country.

15 February 2022 in Open Research Africa
Verified
Journal Article
Open access
PDF file
EMEva Muthamia
Eva Muthamia
SMSamuel Mungai
Samuel Mungai
MMMary Mungai
Mary Mungai
GBGama Bandawe
Gama Bandawe
FQFirdausi Qadri
Firdausi Qadri
JGJesse Gitaka
Jesse Gitaka
Background: The COVID-19 pandemic has resulted in a need for rapid identification of infectious cases. Testing barriers have prohibited adequate screening for SARS-CoV-2, resulting in significant delays in commencement of treatment and outbreak control measures. This study aimed to generate evidence on the performance and implementation characteristics of the BD Veritor™ Plus System rapid antigen test as compared to reverse transcription polymerase chain reaction (RT-PCR) for diagnosis of SARS-CoV-2 in Kenya. Methods: This was a field test performance evaluation in adults undergoing testing for SARS-CoV-2. Recruited participants were classified as SARS-CoV-2-positive based on RT-PCR carried out on nasopharyngeal swabs. Antigen tests were performed with simultaneous RT-PCR on 272 participants, allowing estimation of sensitivity, specificity, positive and negative predictive values for the rapid antigen test. Implementation characteristics were assessed. Results: We enrolled 97 PCR negative symptomatic and 128 PCR negative asymptomatic, and 28 PCR positive symptomatic and 19 PCR positive asymptomatic participants. Compared to RT-PCR, the sensitivity of the rapid antigen test was 94% (95% confidence interval [CI] 86.6 to 100.0) while the specificity was 98% (95% CI 96 to 100). There was no association between sensitivity and symptom status, or between the cycle threshold value and sensitivity of the BD Veritor. The rapid test had a quick turnaround time, required minimal resources, and laboratory personnel conducting testing found it easier to use than RT-PCR. The relatively high sensitivity of BD Veritor may be partially attributed to shortages of RT-PCR testing materials, resulting in specimen analysis delays and potential degradation of viral genetic material. Therefore, in resource-constrained settings, rapid antigen tests may perform better than the reference RT-PCR, resulting in prompt institution of isolation and treatment measures. Conclusion: The BD Veritor rapid antigen test’s high sensitivity should be interpreted with consideration to the challenges occasioned by RT-PCR testing in resource-constrained settings.