Russell Terry

Dr. Russell Terry

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Journal of Endourology
Verified
Journal Article
Closed access
BWBrenton Winship
Brenton Winship
DWDaniel Arthur Wollin
Daniel Arthur Wollin
ECEvan Clayton Carlos
Evan Clayton Carlos
CPChloe Peters
Chloe Peters
JLJingqiu Li
Jingqiu Li
MLMichael Eric Lipkin
Michael Eric Lipkin
Introduction: Temperatures over 43°C—the threshold for cellular injury—may be achieved during ureteroscopic holmium laser lithotripsy. The time to reach and subsequently clear high temperatures at variable laser power settings and irrigation pressures has not been studied. Methods: A flexible or semirigid ureteroscope was placed within an 11/13 F ureteral access sheath inserted into a 250-mL saline bag simulating a normal-caliber ureter, renal pelvis reservoir, and antegrade irrigation flow. A thermocouple was placed adjacent to a 365 μm fiber fired for 45 seconds at 0.6 J/6 Hz, 0.8 J/8 Hz, 1 J/10 Hz, 1 J/20 Hz, and 0.2 J/80 Hz. Irrigation pressures of 200, 100, and 0 mm Hg were tested. Mean temperature changes were recorded with 6°C increase as a threshold for injury (as body temperature is 6°C below 43°C). Results: Semirigid scope: At 200 mm Hg no temperature changes >6°C were observed. At 100 mm Hg, changes >6°C occurred with 1 J/20 Hz within 1 second of activation and returned to ≤6°C within 1 second of cessation. At 0 mm Hg, changes >6°C occurred with all settings; within 1 second at power ≥10 W. Temperatures returned to ≤6°C within 5–10 seconds. Flexible scope: At 200 mm Hg, changes >6°C occurred at 1 J/10 Hz (15 seconds), 0.2 J/80 Hz (3 seconds), and 1 J/20 Hz (2 seconds). Temperatures returned within 6°C of baseline within 2 seconds. At 100 mm Hg, changes >6°C occurred in all but 0.6 J/6 Hz. Temperatures returned to ≤6°C in 5–10 seconds. At 0 mm Hg, all settings produced changes >6°C within 3 seconds, except 0.6 J/6 Hz (35 seconds). Temperatures returned to ≤6°C in under 10 seconds. Conclusions: High temperatures were achieved in our in vitro model in as little as 1 second at common irrigation pressures and laser settings, particularly with a flexible ureteroscope and power ≥10 W. However, with laser cessation, temperatures quickly returned to a safe level at each irrigation pressure.

1 December 2017 in Urology
Verified
Journal Article
Closed access
JHJulia Han
Julia Han
SSStephanie Stillings
Stephanie Stillings
HHHarold Hamann
Harold Hamann
RTRussell Terry
Russell Terry
LMLouis Moy
Louis Moy

1 April 2013 in Arteriosclerosis, Thrombosis, and Vascular Biology
Verified
Journal Article
Closed access
PDF file
RHRebecca Hutcheson
Rebecca Hutcheson
RTRussell Terry
Russell Terry
JCJennifer Chaplin
Jennifer Chaplin
ESErika Smith
Erika Smith
AMAlla Musiyenko
Alla Musiyenko
PRPetra Rocic
Petra Rocic
Objective—: Transient, repetitive occlusion stimulates coronary collateral growth (CCG) in normal animals. Vascular smooth muscle cells (VSMCs) switch to synthetic phenotype early in CCG, then return to contractile phenotype. CCG is impaired in the metabolic syndrome. We determined whether impaired CCG was attributable to aberrant VSMC phenotypic modulation by miR-145–mediated mechanisms, and whether restoration of physiological miR-145 levels in metabolic syndrome (JCR rat) improved CCG. Approach and Results—: CCG was stimulated by transient, repetitive left anterior descending artery occlusion and evaluated after 9 days by coronary blood flow measurements (microspheres). miR-145 was delivered to JCR VSMCs via adenoviral vector (miR-145-Adv). In JCR rats, miR-145 was decreased late in CCG (≈2-fold day 6; ≈4-fold day 9 versus SD), which correlated with decreased expression of smooth muscle-specific contractile proteins (≈5-fold day 6; ≈10-fold day 9 versus SD), indicative of VSMCs’ failure to return to the contractile phenotype late in CCG. miR-145 expression in JCR rats (miR-145-Adv) on days 6 to 9 of CCG completely restored VSMCs contractile phenotype and CCG (collateral/normal zone flow ratio was 0.93±0.09 JCR+miR-145-Adv versus 0.12±0.02 JCR versus 0.87±0.02 SD). Conclusions—: Restoration of VSMC contractile phenotype through miR-145 delivery is a highly promising intervention for restoration of CCG in the metabolic syndrome.

17 August 2018 in Current Urology Reports
Verified
Journal Article
Closed access
PDF file
ARAndrew Rabley
Andrew Rabley
TOTina O’sHea
Tina O’sHea
RTRussell Terry
Russell Terry
SBSharon Byun
Sharon Byun
MMM. Louis Moy
M. Louis Moy

1 November 2019 in Journal of Endourology
Verified
Journal Article
Closed access
BWBrenton Winship
Brenton Winship
RTRussell Terry
Russell Terry
KBKohldon Boydston
Kohldon Boydston
ECEvan Carlos
Evan Carlos
DWDaniel Wollin
Daniel Wollin
MLMichael Lipkin
Michael Lipkin
Introduction: MOSES ™ technology is a holmium:yttrium-aluminum-garnet laser pulse mode shown to minimize stone retropulsion. This may facilitate lithotripsy at higher power settings. However, power and heat production are proportional, and temperatures capable of tissue injury may occur during ureteroscopic lithotripsy. Although previous in vitro studies demonstrate the importance of irrigation and activation time on heat production, the impact of pulse type has not been evaluated. Methods: A flexible ureteroscope with a 365 μm laser fiber was placed in an 11/13 F access sheath inserted into a 50 mL saline bag to simulate a ureter, renal pelvis, and antegrade irrigant flow. A thermocouple was placed adjacent to the laser tip, and the laser fired for 30 seconds at 0.6 J/6 Hz, 0.8 J/8 Hz, 1 J/10 Hz, 1 J/20 Hz, and 0.2 J/70 Hz at irrigation pressure of 100 mmHg. Four runs were tested per setting using short pulse, long pulse (LP), MOSES-contact (MC), and MOSES-distance (MD) modes. The mean temperature changes (dT) were compared and thermal dose was calculated in cumulative equivalent minutes at 43°C (CEM43) using an adjusted baseline of 37°C. CEM43 ≥ 120 minutes was considered the tissue injury threshold. Results: At 0.8 J/8 Hz, LP produced the greatest dT, significantly higher than MC ( p = 0.041). CEM43 did not exceed the injury threshold. At 1 J/10 Hz, dT was significantly higher for LP versus MC and MD ( p = 0.024 and 0.045, respectively). Thermal dose remained below the injury threshold. No differences in dT were seen between pulse types at 0.6 J/6 Hz, 0.2 J/70 Hz, or 1 J/20 Hz. At 1 J/20 Hz, thermal dose exceeded the injury threshold for all pulse types within 3 seconds. Conclusions: Laser pulse type and length seemed to impact heat production in our ureteral model. LP produced significantly greater temperatures at 0.8 J/8 Hz and 1 J/10 Hz relative to MOSES settings. Fortunately, thermal dose remained safe at these settings. Both LP and MOSES technology have been shown to reduce stone retropulsion. At power ≤10 W, the latter may confer this advantage with decreased heat production.

1 January 2022 in Journal of Endourology
Verified
Journal Article
Closed access
RTRussell Terry
Russell Terry
DHDerek S. Ho
Derek S. Ho
DSDominick M. Scialabba
Dominick M. Scialabba
PWPatrick S. Whelan
Patrick S. Whelan
RQRobert Qi
Robert Qi
MLMichael Eric Lipkin
Michael Eric Lipkin
Introduction: Manipulation of Holmium:Yttrium–Aluminum–Garnet laser parameters such as pulse energy (PE), frequency, and duration can impact laser lithotripsy ablation efficiency. In 2017, Lumenis introduced Moses™ Technology, which uses pulse modulation to enhance the delivery of energy from fiber to stone as well as to minimize stone retropulsion. Since the introduction of Moses Technology, other companies have brought additional pulse modulation concepts to market. The purpose of this in vitro study is to compare the pulse characteristics and stone ablation efficiency of Lumenis Moses Technology with Quanta's Vapor Tunnel™. Materials and Methods: Submerged BegoStone phantoms were systematically ablated using either the Lumenis Moses Pulse 120H or the Quanta Litho 100 clinical laser system. Two PEs (0.4 and 1 J), three fiber-stone standoff distances (SDs) (0.5, 1, 2 mm), and all available pulse duration and modulation modes for each laser were tested in combination. Fiber speed was adjusted to scan across the stone surface at either 1 or 10 pulses/mm to form single pulse craters or an ablation trough, respectively. Volumes of single craters and 1 mm trough segments were imaged and quantified using optical coherence tomography. Results: Ablation volumes decreased with decreasing PE and increasing SD. Statistically significant variability was seen between pulse types (PT) at every tested parameter set. Among pulse modulation modes, Moses Distance (MD) was superior at 0.5 mm in all testing and at 2 mm in trough testing. Vapor Tunnel (VT) was superior in 2 mm single crater testing. All modulated pulses performed similarly at 1 mm. Conclusions: In this benchtop model of laser lithotripsy, stone ablation was significantly impacted by PT. MD demonstrated superior or noninferior stone ablation at most tested parameters. VT maintained its efficacy the best as SD increased. Future work should focus on the mechanistic differences of these modes relative to other traditional laser pulse modes.