Takeshi Shimamura

Takeshi Shimamura


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2023 in Geriatrics
Verified
Journal Article
Open access
PDF file
TSTakeshi Shimamura
Takeshi Shimamura
HIHitoshi Ishikawa
Hitoshi Ishikawa
HFHiromi Fujii
Hiromi Fujii
HKHiroshi Katoh
Hiroshi Katoh
Background: Studies that quantify the quality of sit-to-stand-to-sit (STS) motions, particularly in terms of smoothness, are limited. Thus, this study aimed to investigate the possibility and usefulness of quality evaluation during STS motions. Methods: This cross-sectional study enrolled 36 females aged >60 years, including 18 females each in the healthy and hip fracture groups. Measurements were performed at two different speeds: five STS as fast as possible (STSF) and two seconds for each motion (STS2s). Indices of smoothness, including harmonic ratio (HR) and power spectrum entropy (PSE), were calculated and compared from the measured data in each of the three axial directions. Results: HR in the vertical direction was significantly higher in the healthy group (STSF: 3.65 ± 1.74, STS2s: 3.42 ± 1.54) than in the hip fracture group (STSF: 2.67 ± 1.01, STS2s: 2.58 ± 0.83) for STSF and STS2s. Furthermore, PSE for all directions and triaxial composites were significantly lower for STS2s (the healthy group (mediolateral (ML): 7.63 ± 0.31, vertical (VT): 7.46 ± 0.22, anterior–posterior (AP): 7.47 ± 0.15, triaxial: 7.45 ± 0.25), the hip fracture group (ML: 7.82 ± 0.16, VT: 7.63 ± 0.16, AP: 7.61 ± 0.17, triaxial: 7.66 ± 0.17)). Conclusions: This study suggests the usefulness of HR and PSE as quality evaluations for STS motions.

1 January 2023 in Journal of Physical Therapy Science
Verified
Journal Article
Open access
PDF file
TSTakeshi Shimamura
Takeshi Shimamura
Hitoshi IshikawaHitoshi Ishikawa
Hitoshi Ishikawa
HFHiromi Fujii
Hiromi Fujii
HKHiroshi Katoh
Hiroshi Katoh
[Purpose] This study aimed to investigate the usefulness of a quality index in gait for proximal femur fractures. [Participants and Methods] In this study, 20 females with postoperative proximal femur fracture in the preparation phase for discharge (femur fracture group) aged ≥60 years (63.0 ± 3.0 years) and 20 healthy older females (healthy group) participated (75.7 ± 7.7 years) (n=40). Measurements were conducted at comfortable and maximal gait speeds. Power spectrum entropy (PSE), harmonic ratio (HR), and modified HR (mHR), which are smoothness indices, were calculated from the measured data in each of the three axial directions and compared. [Results] The healthy and femur fracture groups showed significant differences in the PSE, HR, and mHR for comfortable and maximal gait speed in the lateral and vertical directions. Furthermore, all directions between the HR and mHR in the femur fracture group had significant differences. [Conclusion] The usefulness of the PSE, HR, and mHR as quality evaluation indices of gait was demonstrated in patients with postoperative femur fractures after unilateral disability.