Fabrizio Innocenti

Dr. Fabrizio Innocenti

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2017 in Remote Sensing
Verified
Journal Article
Open access
PDF file
FIFabrizio Innocenti
Fabrizio Innocenti
RRRod Robinson
Rod Robinson
TGTom Gardiner
Tom Gardiner
AFAndrew Finlayson
Andrew Finlayson
ACAndy Connor
Andy Connor
Methane is one of the most important gaseous hydrocarbon species for both industrial and environmental reasons. Understanding and quantifying methane emissions to atmosphere is therefore an important element of climate change research. Range-resolved infrared differential absorption Lidar (DIAL) measurements provide the means to map and quantify a wide range of different methane sources. This paper describes the DIAL measurement technique and reports the application of an infrared DIAL system to field measurements of methane emissions from active and closed landfill sites. This paper shows how the capability of the DIAL to measure the spatial distribution of methane plumes enables DIAL vertical scans to spatially separate and independently quantify emissions from different sources. It also allows DIAL horizontal scans carried out above the surface to identify emission hot-spots. An overview of the landfill emission surveys carried out over the last decade by the National Physical Laboratory (NPL) DIAL system is presented. These surveys were part of research projects and commercial works aimed to validate the method and to provide reliable information on the methane emissions measuring the total site and area-specific emissions from active areas, capped areas, and gas engine stacks. This work showed that methane emissions are significantly higher for active sites than closed sites due to the methane emitted directly to air from the uncapped active areas. On active sites, the operational tipping areas generally have higher emission levels than the capped areas, although there is considerably variation in the emission from different capped areas. The information obtained with DIAL measurements allow site operators to identify significant fugitive emission sources and validate emissions estimates, and they allow the regulators to revise and update the emission inventories. Operators’ remediation actions driven by DIAL measurements have also been shown to considerably decreased total site methane emission.

14 September 2017 in Remote Sensing
Verified
Journal Article
Open access
PDF file
TGTom Gardiner
Tom Gardiner
JHJon Helmore
Jon Helmore
FIFabrizio Innocenti
Fabrizio Innocenti
RRRod Robinson
Rod Robinson
Area sources are a key contributor to overall greenhouse gas emissions but present a particular challenge to emission measurement techniques due to the heterogeneous nature of the sources. A new Controlled Release Facility (CRF) has been developed that is able to recreate in the field both the distribution and rate of emissions seen in actual industrial applications. The results of a series of field validation experiments involving this facility and an infrared differential absorption Lidar (DIAL) facility are presented, which have demonstrated the capability of the CRF to generate controlled methane emissions from 1.8 kg/h to 11 kg/h with a typical expanded (k = 2) uncertainty of ~0.3 kg/h, and established that any underlying systematic uncertainty in the DIAL measurements across this range of methane emissions is less than 4% (or 0.2 kg/h).

13 February 2023 in Environmental Science & Technology
Verified
Journal Article
Open access
FIFabrizio Innocenti
Fabrizio Innocenti
RRRod Robinson
Rod Robinson
TGTom Gardiner
Tom Gardiner
NHNeil Howes
Neil Howes
NYNigel Yarrow
Nigel Yarrow
This study provides results from measurements of methane emissions from three onshore LNG liquefaction facilities and two regasification facilities across different regions using the Differential Absorption Lidar (DIAL) technique. The measurement approach was to quantify, at each facility, emissions from the key functional elements (FEs), defined as spatially separable areas related to different identified processes. The DIAL technique enabled quantification of emissions at the FE level, allowing emission factors (EFs) to be determined for each FE using activity data. The comprehensive data set presented here should not be used for annualization, however shows the potential of what could be achieved with a larger sample size in terms of potential methane reduction and improving inventory accuracy. Among the benefits in obtaining data with this level of granularity is the possibility to compare the emissions of similar FEs on different plants including FEs present in both liquefaction and regasification facilities. Emissions from noncontinuous sources and superemitters can also be identified and quantified enabling more accurate inventory reporting and targeted maintenance and repair. Site throughput during the measurement periods was used to characterize total site EF; on average the methane losses were 0.018% and 0.070% of throughput at the regasification and liquefaction facilities, respectively.

19 March 2024 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
YLYunsong Liu
Yunsong Liu
Jean-Daniel ParisJean-Daniel Paris
Jean-Daniel Paris
GBGregoire Broquet
Gregoire Broquet
VRVioleta Bescós Roy
Violeta Bescós Roy
TFTania Meixus Fernandez
Tania Meixus Fernandez
PBPhilippe Bousquet
Philippe Bousquet
Methane emissions from natural gas systems are increasingly scrutinized, and accurate reporting requires quantification of site- and source-level measurement. We evaluate the performance of 10 available state-of-the-art CH4 emission quantification approaches against a blind controlled-release experiment at an inerted natural gas compressor station in 2021. The experiment consisted of 17 blind 2 h releases at a single exhaust point or multiple simultaneous ones. The controlled releases covered a range of methane flow rates from 0.01 to 50 kg h−1. Measurement platforms included aircraft, drones, trucks, vans, ground-based stations, and handheld systems. Herewith, we compare their respective strengths, weaknesses, and potential complementarity depending on the emission rates and atmospheric conditions. Most systems were able to quantify the releases within an order of magnitude. The level of errors from the different systems was not significantly influenced by release rates larger than 0.1 kg h−1, with much poorer results for the 0.01 kg h−1 release. It was found that handheld optical gas imaging (OGI) cameras underestimated the emissions. In contrast, the “site-level” systems, relying on atmospheric dispersion, tended to overestimate the emission rates. We assess the dependence of emission quantification performance on key parameters such as wind speed, deployment constraints, and measurement duration. At the low wind speeds encountered (below 2 m s−1), the experiments did not reveal a significant dependence on wind speed. The ability to quantify individual sources degraded during multiple-source releases. Compliance with the Oil and Gas Methane Partnership's (OGMP 2.0) highest level of reporting may require a combination of the specific advantages of each measurement technique and will depend on reconciliation approaches. Self-reported uncertainties were either not available or were based on the standard deviation in a series of independent realizations or fixed values from expert judgment or theoretical considerations. For most systems, the overall relative errors estimated in this study are higher than self-reported uncertainties.

31 August 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
FIFabrizio Innocenti
Fabrizio Innocenti
TGTom Gardiner
Tom Gardiner
RRRod Robinson
Rod Robinson
Differential absorption lidar (DIAL) has been shown to be a very effective technique for the location and quantification of emissions of pollutants and greenhouse gases at industrial facilities. Several field trials have demonstrated the DIAL system performances and contributed to the development of the DIAL methodology, which is the basis of the protocols described in the European Standard EN 17628. While numerous papers have focused on different aspects of DIAL uncertainties, a rigorous propagation of the uncertainties in the DIAL equation has not been found. In this study, all the uncertainty sources contributing to a DIAL concentration measurement are assessed and the impact they have on the calculation of the mass emission rate. We derive the equations for both a DIAL system path-concentration integral and concentration uncertainties. The results from a methane measurement are presented, showing that for a signal to noise ratio on the backscattered lidar signals of 500, the path-concentration integral standard uncertainty is 2.3 ppb km and the concentration standard uncertainty is 92 ppb over a sampling spacing of 45 m. An equation is also presented enabling calculation of the contribution of the concentration uncertainty to the mass emission rate uncertainty.

17 November 2023 in Remote Sensing
Verified
Journal Article
Open access
PDF file
NHNeil Uist Macdonald Howes
Neil Uist Macdonald Howes
FIFabrizio Innocenti
Fabrizio Innocenti
AFAndrew Finlayson
Andrew Finlayson
CDChris Dimopoulos
Chris Dimopoulos
RRRod Robinson
Rod Robinson
TGTom Gardiner
Tom Gardiner
Carbon dioxide (CO2) is a known greenhouse gas and one of the largest contributors to global warming in the Earth’s atmosphere. The remote detection and measurement of CO2 from industrial emissions are not routinely carried out and are typically calculated from the fuel combusted or measured directly within ducted vents. However, these methods are not applicable for the quantification of fugitive emissions of CO2. This work presents the results of remote measurement of CO2 emissions using the differential absorption lidar (DIAL) technique at a wavelength of ~2 µm. The results from the DIAL measurements compare well with simultaneous in-stack measurements, these datasets were plotted against each other and can be described by a linear regression of y (t/h) = 1.04 x − 0.02, suggesting any bias in the DIAL data is likely small. Moreover, using the definition outlined in EN 15267-3 a lower detection limit of 0.12 t/h was estimated for the 2 µm wavelength DIAL data, this is three orders of magnitude lower than the corresponding CO2 detection limit measured by NPL in the 1.5 µm wavelength region. Thus, this paper demonstrates the feasibility of high-resolution, ground-based DIAL measurements for quantifying industrial CO2 emissions.